SearcharxivSearch

arXiv subjects

Alexander Lobko

Publications and source records attributed to Alexander Lobko.

3 recordsLinked to original sources

High-Precision Alignment Techniques for Realizing an Ultracompact Electromagnetic Calorimeters Using Oriented high-Z Scintillator Crystals

Electromagnetic calorimeters used in high-energy physics and astrophysics rely heavily on high-Z inorganic scintillators, such as lead tungstate (PbWO4 or PWO). The crystalline structure and lattice orientation of inorganic scintillators are frequently underestimated in detector design, even though it is known that the crystalline lattice strongly modifies the features of the electromagnetic processes inside the crystal. A novel method has been developed for precisely bonding PWO crystals with aligned atomic planes within 100 {\mu}rad, exploiting X-ray diffraction (XRD) to accurately measure miscut angles. This method demonstrates the possibility to align a layer of crystals along the same crystallographic direction, opening a new technological path towards the development of next-generation electromagnetic calorimeters.

physics.ins-det

Strong Enhancement of Electromagnetic Shower Development in Oriented Scintillating Crystals and Implications for Particle Detectors

A particle traversing a crystal aligned with one of its crystallographic axes experiences a strong electromagnetic field that is constant along the direction of motion over macroscopic distances. For $e^\pm$ and $\gamma$-rays with energies above a few $\mathrm{GeV}$, this field is amplified by the Lorentz boost, to the point of exceeding the Schwinger critical field $\mathcal{E}_0 \sim 1.32 \times 10^{16}~\mathrm{V/cm}$. In this regime, nonlinear quantum-electrodynamical effects occur, such as the enhancement of intense electromagnetic radiation emission and pair production, so that the electromagnetic shower development is accelerated and the effective shower length is reduced compared to amorphous materials. We have investigated this phenomenon in lead tungstate (PbWO$_4$), a high-$Z$ scintillator widely used in particle detection. We have observed a substantial increase in scintillation light at small incidence angles with respect to the main lattice axes. Measurements with $120$-$\mathrm{GeV}$ electrons and $\gamma$-rays between $5$ and $100~\mathrm{GeV}$ demonstrate up to a threefold increase in energy deposition in oriented samples. These findings challenge the current models of shower development in crystal scintillators and could guide the development of next-generation accelerator- and space-borne detectors.

hep-ex

X-Ray Source Based on the Parametric X-Rays

Prospects of parametric x-rays (PXR) application for the development of a tuneable quasi-monochromatic x-ray source for medical imaging are discussed. Analysis of basic requirements for electron accelerator shows that it must be relatively low-energy and high-current linac. In comparison with known ultra-relativistic cases, at low energies PXR properties will be modified to a great extent by multiple scattering of the electrons. PXR intensity dependence on target thickness and beam energy are calculated taking multiple scattering into account. It is concluded that PXR source based on real medical accelerators is feasible and can provide x-ray flux needful for obtaining high quality medical images.

physics.gen-ph