Ion mobility measurements in Ar-CO$_2$, Ne-CO$_2$, and Ne-CO$_2$-N$_{2}$ mixtures, and the effect of water contents

A detector has been constructed for measuring ion mobilities of gas mixtures at atmospheric pressure and room temperature. The detector consists of a standard triple GEM amplification region and a drift region where ions drift. A method has been developed to measure the ions' arrival time at a cathode wire-grid by differentiating the recorded signals on this electrode. Simulations prove that this method is accurate and robust. The ion mobility in different gas mixtures is measured while applying different drift field values ranging from 200 V cm$^{-1}$ to 1100 V cm$^{-1}$. From an extrapolation of a Blanc's law fit to measurements in Ar-CO$_2$ mixtures we find the reduced mobility of the drifting (cluster) ion species in pure argon to be $1.94\pm0.01$ cm$^{2}$ V$^{-1}$ s$^{-1}$ and in pure carbon-dioxide to be $1.10\pm0.01$ cm$^{2}$ V$^{-1}$ s$^{-1}$. Applying the same procedure to our measurements in Ne-CO$_2$ yields $4.06\pm0.07$ cm$^{2}$ V$^{-1}$ s$^{-1}$ and $1.09\pm0.01$ cm$^{2}$ V$^{- 1}$ s$^{-1}$ for the reduced mobilities in pure neon and carbon-dioxide, respectively. Admixtures of N$_2$ to Ne-CO$_2$ reduce somewhat the mobility. For the baseline gas mixture of the future ALICE Time Projection Chamber, Ne- CO$_2$-N$_{2}$ (90-10-5), the measured reduced mobility of the drifting ions is $2.92\pm0.04$ cm$^{2}$ V$^{-1}$ s$^{-1}$. Ion mobilities are examined for different water content ranging from 70 ppm to about 2000 ppm in the gas using Ar-CO$_2$ (90-10) and Ne-CO$_2$ (90-10). A slight decrease of ion mobility is observed for the addition of several hundred ppm of water.

physics.ins-det

Measurements of ion mobility in argon and neon based gas mixtures

As gaseous detectors are operated at high rates of primary ionisation, ions created in the detector have a considerable impact on the performance of the detector. The upgraded ALICE Time Projection Chamber (TPC) will operate during LHC Run$\,3$ with a substantial space charge density of positive ions in the drift volume. In order to properly simulate such space charges, knowledge of the ion mobility $K$ is necessary. To this end, a small gaseous detector was constructed and the ion mobility of various gas mixtures was measured. To validate the corresponding signal analysis, simulations were performed. Results are shown for several argon and neon based mixtures with different $\textrm{CO}_2$ fractions. A decrease of $K$ was measured for increasing water content.

physics.ins-det