SearcharxivSearch

arXiv subjects

Alexandre Bresson

Publications and source records attributed to Alexandre Bresson.

At least 19 recordsLinked to original sources

Quantum sensing of radiofrequency fields using cold Rydberg atoms in a super-molasses trap

We demonstrate the quantum sensing of radiofrequency fields based on cold Rydberg atoms in a super-molasses trap, without the need for magnetic coils. Our approach combines the metrological advantages of cold atoms with a metal-free dielectric sensor head minimizing perturbations to the electromagnetic environment, a feature that was previously restricted to vapor-cell-based devices. Moreover, the absence of inductive loads allows to rapidly alternate between the cooling phase and the Rydberg excitation, leading to trap-loss spectroscopy signals one order of magnitude narrower than for conventional magneto-optical traps. This enables self-calibrated microwave power measurements with an unprecedented dynamic range of 43dB, opening the door to new perspectives of applications in calibration measurements. We also report a scale factor linearity better than 1%, the absence of drifts over several tens of minutes leading to a 3$\mu$V/cm resolution, and the possibility to retrieve the ellipticity of the applied microwave field. By demonstrating a cold-atom metrological platform in a compact dielectric sensor head, this work paves the way for new applications in the field of radiofrequency measurements with Rydberg atoms, and in other fields of quantum sensing based on cold atoms such as magnetometry, gravimetry or inertial navigation.

physics.atom-ph

Characterisation of a triple-species 87Rb/85Rb/133Cs magneto-optical trap towards cold-atom interferometry

We present the simultaneous trapping and cooling of ${}^{85}$Rb, ${}^{87}$Rb and ${}^{133}$Cs in a triple-species magneto-optical trap (MOT). This demonstration is obtained using an all-fibre compact and robust laser system based on telecom 1.5 $\mu$m and 2 $\mu$m technologies. We characterise the two-body interspecies losses in the double and triple-species MOT. We calculate the two-body interspecies trap-loss coefficient for the ${}^{85}$Rb/${}^{133}$Cs and the ${}^{87}$Rb/${}^{133}$Cs pairs, representing a variation of less than 7 \% in atom number. No losses are observed between ${}^{85}$Rb and ${}^{87}$Rb in our experimental conditions. We find that interspecies interactions inside the triple-species MOT do not prevent trapping and cooling 10$^{8}$ atoms for each species, making our system suitable for future multi-species cold-atom interferometry applications.

physics.atom-ph

Impact of rotation on a cold atom interferometer and compensation strategy

Rotations play a detrimental role in achieving ultra-high-performance inertial measurements with an atom interferometer, leading potentially to a total loss of interference contrast and the emergence of dominant phase shift biases. This becomes particularly significant when considering operation in dynamic conditions such as those encountered in Earth orbiting satellites in the perspective of future space gravity missions on-boarding a cold atom accelerometer. We study in this context the impact of rotation on the phase shift and contrast of an atom interferometer and investigate mitigation strategies. An analytical model is derived and compared to experimental demonstrations carried out using an original setup in which the well-controlled proof-mass of a space electrostatic accelerometer is used as the retro-reflection mirror of a cold atom gravimeter. By properly counter-rotating the electrostatic proof-mass, we demonstrate for instance the possibility of recovering the interferometer contrast, otherwise equal to zero, to a level better than 90%, in both cases of constant angular velocities or in presence of angular accelerations. Our results demonstrate the possibility to perform high performance inertial measurements with a cold atom interferometer in a challenging environments.

physics.atom-ph

Comparison and optimisation of hybridization algorithms for onboard classical and quantum accelerometers

We study two hybridization algorithms used for the combination of a quantum inertial sensor based on atom interferometry with a classical inertial sensor for onboard acceleration measurements. The first is based on the direct extraction of the interferometer phase, and was previously used in seaborne and airborne gravity measurement campaigns. The second is based on the combination of three consecutive measurements and was originally developed to increase the measurement range of the quantum sensor beyond its linear range. After comparing their performances using synthetic data, we implement them on acceleration data collected in a recent airborne campaign and evaluate the bias and the scale factor error of the classical sensor. We then extend their scope to the dynamical evaluation of other key measurement parameters (e.g. alignment errors). We demonstrate an improvement in the correlation between the two accelerometers' measurements and a significant reduction of the error in the estimation of the bias of the classical sensor.

quant-ph

Quantum sensing of acceleration and rotation by interfering magnetically-launched atoms

Accurate measurement of inertial quantities is essential in geophysics, geodesy, fundamental physics and navigation. For instance, inertial navigation systems require stable inertial sensors to compute the position and attitude of the carrier. Here, we present an architecture for a compact cold-atom accelerometer-gyroscope based on a magnetically launched atom interferometer. Characterizing the launching technique, we demonstrate 700 ppm gyroscope scale factor stability over one day, while acceleration and rotation rate bias stabilities of $7 \times 10^{-7}$ m/s$^2$ and $4 \times 10^{-7}$ rad/s are reached after two days of integration of the cold-atom sensor. Hybridizing it with a classical accelerometer and gyroscope, we correct their drift and bias to achieve respective 100-fold and 3-fold increase on the stability of the hybridized sensor compared to the classical ones. Compared to state-of-the-art atomic gyroscope, the simplicity and scalability of our launching technique make this architecture easily extendable to a compact full six-axis inertial measurement unit, providing a pathway towards autonomous positioning and orientation using cold-atom sensors.

quant-ph

Metrology of microwave fields based on trap-loss spectroscopy with cold Rydberg atoms

We demonstrate a new approach for the metrology of microwave fields based on the trap-loss-spectroscopy of cold Rydberg atoms in a magneto-optical trap. Compared to state-of-the-art sensors using room-temperature vapors, cold atoms allow longer interaction times, better isolation from the environment and a reduced Doppler effect. Our approach is particularly simple as the detection relies on fluorescence measurements only. Moreover, our signal is well described by a two-level model across a broad measurement range, allowing in principle to reconstruct the amplitude and the frequency of the microwave field simultaneously without the need for an external reference field. We report on a scale factor linearity at the percent level and no noticeable drifts over two hours, paving the way for new applications of cold Rydberg atoms in metrology such as calibrating blackbody shifts in state-of-the-art optical clocks, monitoring the Earth cryosphere from space, measuring the cosmic microwave background or searching for dark matter.

physics.atom-ph

Airborne absolute gravimetry with a quantum sensor, comparison with classical technologies

We report an airborne gravity survey with an absolute gravimeter based on atom interferometry and two relative gravimeters: a classical LaCoste\&Romberg (L\&R) and a novel iMAR strap-down Inertial Measurement Unit (IMU). We estimated measurement errors for the quantum gravimeter ranging from 0.6 to 1.3 mGal depending on the flight conditions and the filtering used. Similar measurement errors are obtained with iMAR strapdown gravimeter but the long term stability is five times worse. The traditional L\&R platform gravimeter shows larger measurement errors (3 - 4 mGal). Airborne measurements have been compared to marine, land and altimetry derived gravity data. We obtain a good agreement for the quantum gravimeter with standard deviations and means on differences below or equal to 2 mGal. This study confirms the potential of quantum technology for absolute airborne gravimetry which is particularly interesting for mapping shallow water or mountainous areas and for linking ground and satellite measurements with homogeneous absolute referencing.

physics.atom-ph

Hybrid electrostatic-atomic accelerometer for future space gravity missions

Long term observation of temporal Earth's gravity field with enhanced temporal and spatial resolution is a major objective for future satellite gravity missions. Improving the performance of the accelerometers present in such missions is one of the main path to explore. In this context, we propose to study an original concept of a hybrid accelerometer associating a state-of-the-art electrostatic accelerometer (EA) and a promising quantum sensor based on cold atom interferometry. To assess the performance potential of such instrument, numerical simulations have been performed to determine its impact in term of gravity field retrieval. Taking advantage of the long term stability of the cold atom interferometer (CAI), it has been shown that the reduced drift of the hybrid sensor could lead to improved gravity field retrieval. Nevertheless this gain vanishes once temporal variations of the gravity field and related aliasing effects are taken into account. Improved de-aliasing models or some specific satellite constellations are then required to maximize the impact of the accelerometer performance gain. To evaluate the achievable acceleration performance in orbit, a numerical simulator of the hybrid accelerometer has been developed and preliminary results are given. The instrument simulator has been in part validated by reproducing the performance achieved with a hybrid lab prototype operating on ground. The problematic of satellite rotation impact on the CAI has been also investigated both with instrument performance simulations and experimental demonstrations. It has been shown that the proposed configuration, where the EA's proof-mass acts as the reference mirror for the CAI, seems a promising approach to allow the mitigation of satellite rotation. A preliminary design has been elaborated along with a preliminary error, mass, volume and electrical power consumption budget.

physics.atom-ph

Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map

We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with ESA and national space and research funding agencies.

astro-ph.IM

Atom interferometry using $\sigma^+$-$\sigma^-$ Raman transitions between $F=1,m_F=\mp1$ and $F=2,m_F=\pm1$

We report on the experimental demonstration of a horizontal accelerometer based on atom interferometry using counterpropagative Raman transitions between the states $F=1,m_F=\mp1$ and $F=2,m_F=\pm1$ of $^{87}$Rb. Compared to the $F=1,m_F=0 \leftrightarrow F=2,m_F=0$ transition usually used in atom interferometry, our scheme presents the advantages to have only a single counterpropagating transition allowed in a retroreected geometry, to use the same polarization configuration than the magneto-optical trap and to allow the control of the atom trajectory with magnetic forces. We demonstrate horizontal acceleration measurement in a close-to-zero velocity regime using a singlediffraction Raman process with a short-term sensitivity of $25 \times 10^{-5}$ m.s$^{-2}$.Hz$^{-1/2}$. We discuss specific features of the technique such as spontaneous emission, light-shifts and effects of magnetic field inhomogeneities. We finally give possible applications of this technique in metrology or for cold-atom inertial sensors dedicated to onboard applications.

physics.atom-ph

Absolute airborne gravimetry with a cold atom sensor

Measuring gravity from an aircraft is essential in geodesy, geophysics and exploration. Today, only relative sensors are available for airborne gravimetry. This is a major drawback because of the calibration and drift estimation procedures which lead to important operational constraints and measurement errors. Here, we report an absolute airborne gravimeter based on atom interferometry. This instrument has been first tested on a motion simulator leading to gravity measurements noise of 0.3 mGal for 75 s filtering time constant. Then, we realized an airborne campaign across Iceland in April 2017. From a repeated line and crossing points, we obtain gravity measurements with an estimated error between 1.7 and 3.9 mGal. The airborne measurements have also been compared to upward continued ground gravity data and show differences with a standard deviation ranging from 3.3 to 6.2 mGal and a mean value ranging from -0.7 mGal to -1.9 mGal.

physics.app-ph

Zero-velocity atom interferometry using a retroreflected frequency chirped laser

Atom interferometry using stimulated Raman transitions in a retroreflected configuration is the first choice in high precision measurements because it provides low phase noise, high quality Raman wavefront and simple experimental setup. However, it cannot be used for atoms at zero velocity because two pairs of Raman lasers are simultaneously resonant. Here we report a method which allows to lift this degeneracy by using a frequency chirp on the Raman lasers. Using this technique, we realize a Mach-Zehnder atom interferometer hybridized with a force balanced accelerometer which provides horizontal acceleration measurements with a short-term sensitivity of $3.2\times 10^{-5}$ m.s$^{-2}$/$\sqrt{Hz}$. We check at the level of precision of our experiment the absence of bias induced by this method. This technique could be used for multiaxis inertial sensors, tiltmeters or atom interferometry in a microgravity environment.

physics.atom-ph

Proof-of-principle demonstration of vertical gravity gradient measurement using a single proof mass double-loop atom interferometer

We demonstrate a proof-of-principle of direct Earth gravity gradient measurement with an atom interferometer-based gravity gradiomter using a single proof mass of cold 87 rubidium atoms. The atomic gradiometer is implemented in the so-called double-loop configuration, hence providing a direct gravity gradient dependent phase shift insensitive do DC acceleration and constant rotation rate. The atom interferometer (AI) can be either operated as a gravimeter or a gradiomter by simply adding an extra Raman $\pi$-pulse. We demonstrate gravity gradient measurements first using a vibration isolation platform and second without seismic isolation using the correlation between the AI signal and the vibration signal measured by an auxilliary classical accelerometer. The simplicity of the experimental setup (a single atomic source and unique detection) and the immunity of the AI to rotation-induced contrast loss, make it a good candidate for onboard gravity gradient measurements.

physics.atom-ph

New concepts of inertial measurements with multi-species atom interferometry

In the field of cold atom inertial sensors, we present and analyze innovative configurations for improving their measurement range and sensitivity, especially attracting for onboard applications. These configurations rely on multi-species atom interferometry, involving the simultaneous manipulation of different atomic species in a unique instrument to deduce inertial measurements. Using a dual-species atom accelerometer manipulating simultaneously both isotopes of rubidium, we report a preliminary experimental realization of original concepts involving the implementation of two atom interferometers first with different interrogation times and secondly in phase quadrature. These results open the door to a new generation of atomic sensors relying on high performance multi-species atom interferometric measurements.

physics.atom-ph

Fiber laser system for cesium and rubidium atom interferometry

We present an innovative fiber laser system for both cesium and rubidium manipulation. The architecture is based on frequency conversion of two lasers at 1560 nm and 1878 nm. By taking advantage of existing fiber components at these wavelengths, we demonstrate an all fiber laser system delivering 350 mW at 780 nm for rubidium and 210 mW at 852 nm for cesium. This result highlights the promising nature of such laser system especially for Cs manipulation for which no fiber laser system has been reported. It offers new perspectives for the development of atomic instruments dedicated to onboard applications and opens the way to a new generation of atom interferometers involving three atomic species $^{85}$Rb, $^{87}$Rb and $^{133}$Cs for which we propose an original laser architecture.

physics.atom-ph

A phase shift formulation for N-light-pulse atom interferometers: application to inertial sensing

We report on an original and simple formulation of the phase shift in N-light-pulse atom interferometers. We consider atomic interferometers based on two-photon transitions (Raman transitions or Bragg pulses). Starting from the exact analytical phase shift formula obtained from the atom optics ABCD formalism, we use a power series expansion in time of the position of the atomic wave packet with respect to the initial condition. The result of this expansion leads to a formulation of the interferometer phase shift where the leading coefficient in the phase terms up to T^k dependences (k >= 0) in the time separation T between pulses, can be simply expressed in terms of a product between a Vandermonde matrix, and a vector characterizing the two-photon pulse sequence of the interferometer. This simple coefficient dependence of the phase shift reflects very well the atom interferometer's sensitivity to a specific inertial field in the presence of multiple gravito-inertial effects. Consequently,we show that this formulation is well suited when looking for selective atomic sensors of accelerations, rotations, or photon recoil only, which can be obtained by simply zeroing some specific coefficients. We give a theoritical application of our formulation to the photon recoil measurement.

physics.atom-ph

Frequency doubled telecom fiber laser for a cold atom interferometer using optical lattices

A compact and robust laser system, based on a frequency-doubled telecom laser, providing all the lasers needed for a rubidium cold atom interferometer using optical lattices is presented. Thanks to an optical switch at 1.5 μm and a dual-wavelength second harmonic generation system, only one laser amplifier is needed for all the laser system. Our system delivers at 780 nm a power of 900 mW with a detuning of 110 GHz for the optical lattice and a power of 650 mW with an adjustable detuning between 0 and -1 GHz for the laser cooling, the detection and the Raman transitions.

physics.optics

Narrow linewidth single laser source system for onboard atom interferometry

A compact and robust laser system for atom interferometry based on a frequency-doubled telecom laser is presented. Thanks to an original stabilization architecture on a saturated absorption setup, we obtain a frequency-agile laser system allowing fast tuning of the laser frequency over 1 GHz in few ms using a single laser source. The different laser frequencies used for atom interferometry are generated by changing dynamically the frequency of the laser and by creating sidebands using a phase modulator. A laser system for Rubidium 87 atom interferometry using only one laser source based on a frequency doubled telecom fiber bench is then built. We take advantage of the maturity of fiber telecom technology to reduce the number of free-space optical components (which are intrinsically less stable) and to make the setup compact and much less sensitive to vibrations and thermal fluctuations. This source provides spectral linewidth below 2.5 kHz, which is required for precision atom interferometry, and particularly for a high performance atomic inertial sensor.

physics.atom-ph