SearcharxivSearch

arXiv subjects

Alexandre Moreau-Gaudry

Publications and source records attributed to Alexandre Moreau-Gaudry.

14 recordsLinked to original sources

Offline identification of surgical deviations in laparoscopic rectopexy

Objective: A median of 14.4% of patient undergone at least one adverse event during surgery and a third of them are preventable. The occurrence of adverse events forces surgeons to implement corrective strategies and, thus, deviate from the standard surgical process. Therefore, it is clear that the automatic identification of adverse events is a major challenge for patient safety. In this paper, we have proposed a method enabling us to identify such deviations. We have focused on identifying surgeons' deviations from standard surgical processes due to surgical events rather than anatomic specificities. This is particularly challenging, given the high variability in typical surgical procedure workflows. Methods: We have introduced a new approach designed to automatically detect and distinguish surgical process deviations based on multi-dimensional non-linear temporal scaling with a hidden semi-Markov model using manual annotation of surgical processes. The approach was then evaluated using cross-validation. Results: The best results have over 90% accuracy. Recall and precision were superior at 70%. We have provided a detailed analysis of the incorrectly-detected observations. Conclusion: Multi-dimensional non-linear temporal scaling with a hidden semi-Markov model provides promising results for detecting deviations. Our error analysis of the incorrectly-detected observations offers different leads in order to further improve our method. Significance: Our method demonstrated the feasibility of automatically detecting surgical deviations that could be implemented for both skill analysis and developing situation awareness-based computer-assisted surgical systems.

eess.IV

First Clinical Experience in Urologic Surgery with a Novel Robotic Lightweight Laparoscope Holder

Purpose: To report the feasibility and the safety of a surgeon-controlled robotic endoscope holder in laparoscopic surgery. Materials and methods: From March 2010 to September 2010, 20 patients were enrolled prospectively to undergo a laparoscopic surgery using an innovative robotic endoscope holder. Two surgeons performed 6 adrenalectomies, 4 sacrocolpopexies, 5 pyeloplasties, 4 radical prostatectomies and 1 radical nephrectomy. Demographic data, overall set-up time, operative time, number of assistants needed were reviewed. Surgeon's satisfaction regarding the ergonomics was assessed using a ten point scale. Postoperative clinical outcomes were reviewed at day 1 and 1 month postoperatively. Results: The per-protocol analysis was performed on 17 patients for whom the robot was effectively used for surgery. Median age was 63 years, 10 patients were female (59%). Median BMI was 26.8. Surgical procedures were completed with the robot in 12 cases (71 %). Median number of surgical assistant was 0. Overall set-up time with the robot was 19 min, operative time was 130 min) during which the robot was used 71% of the time. Mean hospital stay was 6.94 days $\pm$ 2.3. Median score regarding the easiness of use was 7. Median pain level was 1.5/10 at day 1 and 0 at 1 month postoperatively. Open conversion was needed in 1 case (6 %) and 4 minor complications occurred in 2 patients (12%). Conclusion: This use of this novel robotic laparoscope holder is safe, feasible and it provides a good comfort to the surgeon.

cs.RO

Mapping of transrectal ultrasonographic prostate biopsies: quality control and learning curve assessment by image processing

Objective: Mapping of transrectal ultrasonographic (TRUS) prostate biopsies is of fundamental importance for either diagnostic purposes or the management and treatment of prostate cancer, but the localization of the cores seems inaccurate. Our objective was to evaluate the capacities of an operator to plan transrectal prostate biopsies under 2-dimensional TRUS guidance using a registration algorithm to represent the localization of biopsies in a reference 3-dimensional ultrasonographic volume. Methods: Thirty-two patients underwent a series of 12 prostate biopsies under local anesthesia performed by 1 operator using a TRUS probe combined with specific third-party software to verify that the biopsies were indeed conducted within the planned targets. RESULTS: The operator reached 71% of the planned targets with substantial variability that depended on their localization (100% success rate for targets in the middle and right parasagittal parts versus 53% for targets in the left lateral base). Feedback from this system after each series of biopsies enabled the operator to significantly improve his dexterity over the course of time (first 16 patients: median score, 7 of 10 and cumulated median biopsy length in targets of 90 mm; last 16 patients, median score, 9 of 10 and a cumulated median length of 121 mm; P = .046). Conclusions: In addition to being a useful tool to improve the distribution of prostate biopsies, the potential of this system is above all the preparation of a detailed "map" of each patient showing biopsy zones without substantial changes in routine clinical practices.

physics.med-ph

Framework for 3D TransRectal Ultrasound

Prostate biopsies are mainly performed under 2D TransRectal UltraSound (TRUS) control by sampling the prostate according to a predefined pattern. In case of first biopsies, this pattern follows a random systematic plan. Sometimes, repeat biopsies can be needed to target regions unsampled by previous biopsies or resample critical regions (for example in case of cancer expectant management or previous prostatic intraepithelial neoplasia findings). From a clinical point of view, it could be useful to control the 3D spatial distribution of theses biopsies inside the prostate. Modern 3D-TRUS probes allow acquiring high-quality volumes of the prostate in few seconds. We developed a framework to track the prostate in 3D TRUS images. It means that if one acquires a reference volume at the beginning of the session and another during each biopsy, it is possible to determine the relationship between the prostate in the reference and the others volumes by aligning images. We used this tool to evaluate the ability of a single operator (a young urologist assistant professor) to perform a pattern of 12 biopsies under 2D TRUS guidance.

cs.OH

Prostate biopsies guided by three-dimensional real-time (4-D) transrectal ultrasonography on a phantom: comparative study versus two-dimensional transrectal ultrasound-guided biopsies

OBJECTIVE: This study evaluated the accuracy in localisation and distribution of real-time three-dimensional (4-D) ultrasound-guided biopsies on a prostate phantom. METHODS: A prostate phantom was created. A three-dimensional real-time ultrasound system with a 5.9MHz probe was used, making it possible to see several reconstructed orthogonal viewing planes in real time. Fourteen operators performed biopsies first under 2-D then 4-D transurethral ultrasound (TRUS) guidance (336 biopsies). The biopsy path was modelled using segmentation in a 3-D ultrasonographic volume. Special software was used to visualise the biopsy paths in a reference prostate and assess the sampled area. A comparative study was performed to examine the accuracy of the entry points and target of the needle. Distribution was assessed by measuring the volume sampled and a redundancy ratio of the sampled prostate. RESULTS: A significant increase in accuracy in hitting the target zone was identified using 4-D ultrasonography as compared to 2-D. There was no increase in the sampled volume or improvement in the biopsy distribution with 4-D ultrasonography as compared to 2-D. CONCLUSION: The 4-D TRUS guidance appears to show, on a synthetic model, an improvement in location accuracy and in the ability to reproduce a protocol. The biopsy distribution does not seem improved.

cs.OH

Suppléance perceptive par électro-stimulation linguale embarquée : perspectives pour la prévention des escarres chez le blessé médullaire

We introduce the innovative technologies, based on the concept of "sensory substitution", we are developing in the fields of biomedical engineering and human disability. Precisely, our goal is to design, develop and validate practical assistive biomedical and/or technical devices and/or rehabilitating procedures for persons with disabilities, using artificial tongue-placed tactile biofeedback systems. This paper proposes an application for pressure sores prevention in case of spinal cord injuries (persons with paraplegia, or tetraplegia).

physics.med-ph

Pressure sensor-based tongue-placed electrotactile biofeedback for balance improvement - Biomedical application to prevent pressure sores formation and falls

We introduce the innovative technologies, based on the concept of "sensory substitution", we are developing in the fields of biomedical engineering and human disability. Precisely, our goal is to design, develop and validate practical assistive biomedical and/or technical devices and/or rehabilitating procedures for persons with disabilities, using artificial tongue-placed tactile biofeedback systems. Proposed applications are dealing with: (1) pressure sores prevention in case of spinal cord injuries (persons with paraplegia, or tetraplegia); and (2) balance control improvement to prevent fall in older and/or disabled adults. This paper describes the architecture and the functioning principle of these biofeedback systems and presents preliminary results of two feasibility studies performed on young healthy adults.

physics.med-ph

Artificial Tongue-Placed Tactile Biofeedback for perceptual supplementation: application to human disability and biomedical engineering

The present paper aims at introducing the innovative technologies, based on the concept of "sensory substitution" or "perceptual supplementation", we are developing in the fields of human disability and biomedical engineering. Precisely, our goal is to design, develop and validate practical assistive biomedical and/technical devices and/or rehabilitating procedures for persons with disabilities, using artificial tongue-placed tactile biofeedback systems. Proposed applications are dealing with: (1) pressure sores prevention in case of spinal cord injuries (persons with paraplegia, or tetraplegia); (2) ankle proprioceptive acuity improvement for driving assistance in older and/or disabled adults; and (3) balance control improvement to prevent fall in older and/or disabled adults. This paper presents results of three feasibility studies performed on young healthy adults.

physics.med-ph

Prévention des escarres chez les paraplégiques : une nouvelle approche par électrostimulation linguale

Pressure ulcers are recognized as a major health issue in individuals with spinal cord injuries and new approaches to prevent this pathology are necessary. An innovative health strategy is being developed through the use of computer and sensory substitution via the tongue in order to compensate for the sensory loss in the buttock area for individuals with paraplegia. This sensory compensation will enable individuals with spinal cord injuries to be aware of a localized excess of pressure at the skin/seat interface and, consequently, will enable them to prevent the formation of pressure ulcers by relieving the cutaneous area of suffering. This work reports an initial evaluation of this approach and the feasibility of creating an adapted behavior, with a change in pressure as a response to electro-stimulated information on the tongue. Obtained during a clinical study in 10 healthy seated subjects, the first results are encouraging, with 92% success in 100 performed tests. These results, which have to be completed and validated in the paraplegic population, may lead to a new approach to education in health to prevent the formation of pressure ulcers within this population. Keywords: Spinal Cord Injuries, Pressure Ulcer, Sensory Substitution, Health Education, Biomedical Informatics.

physics.med-ph

Présentation d'une méthodologie d'évaluation de la faisabilité de la substitution sensorielle par électrostimulation linguale pour la prévention des escarres chez le bléssé médullaire paraplégique

Pressure ulcers are recognized as a major health issue in individuals with spinal cord injuries and new approaches to prevent this pathology are necessary. An innovative health strategy is being developed through the use of computer and sensory substitution via the tongue in order to compensate for the sensory loss in the buttock area for individuals with paraplegia. This sensory compensation will enable individuals with spinal cord injuries to be aware of a localized excess of pressure at the skin/seat interface and, consequently, will enable them to prevent the formation of pressure ulcers by relieving the cutaneous area of suffering. This work reports an initial evaluation of this approach and the feasibility of creating an adapted behavior, with a change in pressure as a response to electro-stimulated information on the tongue.

physics.med-ph

A New Health Strategy to Prevent Pressure Ulcer Formation in Paraplegics using Computer and Sensory Substitution via the Tongue

Pressure ulcers are recognized as a major health issue in individuals with spinal cord injuries and new approaches to prevent this pathology are necessary. An innovative health strategy is being developed through the use of computer and sensory substitution via the tongue in order to compensate for the sensory loss in the buttock area for individuals with paraplegia. This sensory compensation will enable individuals with spinal cord injuries to be aware of a localized excess of pressure at the skin/seat interface and, consequently, will enable them to prevent the formation of pressure ulcers by relieving the cutaneous area of suffering. This work reports an initial evaluation of this approach and the feasibility of creating an adapted behavior, with a change in pressure as a response to electro-stimulated information on the tongue. Obtained during a clinical study in 10 healthy seated subjects, the first results are encouraging, with 92% success in 100 performed tests. These results, which have to be completed and validated in the paraplegic population, may lead to a new approach to education in health to prevent the formation of pressure ulcers within this population.

physics.med-ph

Utilisation de la substitution sensorielle par électro-stimulation linguale pour la prévention des escarres chez les paraplégiques. Etude préliminaire

Pressure ulcers are recognized as a major health issue in individuals with spinal cord injuries and new approaches to prevent this pathology are necessary. An innovative health strategy is being developed through the use of computer and sensory substitution via the tongue in order to compensate for the sensory loss in the buttock area for individuals with paraplegia. This sensory compensation will enable individuals with spinal cord injuries to be aware of a localized excess of pressure at the skin/seat interface and, consequently, will enable them to prevent the formation of pressure ulcers by relieving the cutaneous area of suffering. This work reports an initial evaluation of this approach and the feasibility of creating an adapted behavior, with a change in pressure as a response to electro-stimulated information on the tongue. Obtained during a clinical study in 10 healthy seated subjects, the first results are encouraging, with 92% success in 100 performed tests. These results, which have to be completed and validated in the paraplegic population, may lead to a new approach to education in health to prevent the formation of pressure ulcers within this population. Keywords: Spinal Cord Injuries, Pressure Ulcer, Sensory Substitution, Health Education, Biomedical Informatics.

physics.med-ph