SearcharxivSearch

arXiv subjects

Alexei Kanareykin

Publications and source records attributed to Alexei Kanareykin.

5 recordsLinked to original sources

Continuous and Coordinated Efforts of Structure Wakefield Acceleration (SWFA) Development for an Energy Frontier Machine

Structure wakefield acceleration (SWFA) is well suited for the linear collider (LC) application due to its natural ability to accelerate positrons and preserve emittance. Under the SWFA roadmap, which was developed in response to Snowmass 2013 recommendations, four principal technologies: drive beam, main beam, wakefield structure, and LC facility design, have been investigated. The two SWFA schemes under development are the collinear wakefield accelerator (CWA), in which the drive and main beam follow the same path through a structure, and the two-beam accelerator (TBA), where the drive and main beam pass through different structures. To further advance the SWFA technology in the next decade, continuous and coordinated efforts must be carried out in a more synchronized way. This whitepaper is written to address the research needs in SWFA for preparation of Snowmass 2022.

physics.acc-ph

Studies of the superconducting traveling wave cavity for high gradient LINAC

Use of a traveling wave (TW) accelerating structure with a small phase advance per cell instead of standing wave may provide a significant increase of accelerating gradient in a superconducting linear accelerator. The TW section achieves an accelerating gradient 1.2-1.4 larger than TESLA-shaped standing wave cavities for the same surface electric and magnetic fields. Recent tests of an L-band single-cell cavity with a waveguide feedback demonstrated an accelerating gradient comparable to the gradient in a single-cell ILC-type cavity from the same manufacturer. This article presents the next stage of the 3- cell TW resonance ring development which will be tested in the traveling wave regime. The main simulation results of the microphonics and Lorentz Force Detuning (LFD) are also considered.

physics.acc-ph

Three-cell traveling wave superconducting test structure

Use of a superconducting traveling wave accelerating (STWA) structure with a small phase advance per cell rather than a standing wave structure may provide a significant increase of the accelerating gradient in the ILC linac. For the same surface electric and magnetic fields the STWA achieves an accelerating gradient 1.2 larger than TESLA-like standing wave cavities. The STWA allows also longer acceleration cavities, reducing the number of gaps between them. However, the STWA structure requires a SC feedback waveguide to return the few hundreds of MW of circulating RF power from the structure output to the structure input. A test single-cell cavity with feedback was designed, manufactured and successfully tested demonstrating the possibility of a proper processing to achieve a high accelerating gradient. These results open way to take the next step of the TW SC cavity development: to build and test a traveling-wave three-cell cavity with a feedback waveguide. The latest results of the single-cell cavity tests are discussed as well as the design of the test 3-cell TW cavity.

physics.acc-ph

Studies of Particle Acceleration by an Active Microwave Medium

The PASER is potentially a very attractive method for particle acceleration, in which energy from an active medium is transferred to a charged particle beam. The effect is similar to the action of a maser or laser with the stimulated emission of radiation being produced by the virtual photons in the electromagnetic field of the beam. We have been investigating the possibility of developing a demonstration PASER operating at X-band. The less restrictive beam transport and device dimensional tolerances required for working at X-band rather than optical frequencies as well as the widespread application of X-band hardware in accelerator technology all contribute to the attractiveness of performing a PASER demonstration experiment in this frequency range. Key to this approach is the availability of a new class of active materials that exhibit photoinduced electron spin polarization. We will report on the status of active material development and measurements, numerical simulations, and progress towards a planned microwave PASER acceleration experiment at the Argonne Wakefield Accelerator facility.

physics.acc-ph

Wakefields Generated by Electron Beams Passing Through a Waveguide Loaded With an Active Medium

The wakefields of a relativistic electron beam passing through a waveguide loaded with an active medium with weak resonant dispersion have been considered. For the calculations in this paper the parameters of the medium are those of a solution of fullerene (C60) in a nematic liquid crystal that exhibits activity in the X-band. It was shown that several of the TM accelerating modes can be amplified for the geometries under consideration; structures in which higher order modes are amplified exhibit essential advantages as PASERs. In particular, the amplification of the highest mode occurs in a structure loaded with a rather thick active medium layer that maximizes the energy stored by the active medium.

physics.acc-ph