SearcharxivSearch

arXiv subjects

Alexej Jerschow

Publications and source records attributed to Alexej Jerschow.

14 recordsLinked to original sources

Single-Scan Characterization of $^{14}$N Nuclei via $^1$H-Detected Rotating-Frame Relaxometry

$^{14}$N NMR is notoriously difficult to perform in liquids due to the very fast spin relaxation and the large quadrupolar couplings, which render many signals invisible. We show here how $^{14}$N nuclei of biomolecular constituents can be probed indirectly by reintroducing the scalar relaxation of the second kind contribution to the polarization lifetimes of J-coupled protons in double resonance spin-locking experiments. The enhanced $^1$H relaxation rates in the rotating-frame allow for direct evaluation of nitrogen chemical shift and polarization lifetimes, from which one- and even two-bond $^1$H-$^{14}$N scalar couplings as well as $^{14}$N quadrupolar interactions can be determined. We demonstrate the versatility of this method by characterizing $^1$H-$^{14}$N spin pairs in several molecules of biological importance, showing proton relaxation enhancements beyond one order of magnitude. We further observe a pronounced effect from intermolecular hydrogen bonding. Our approach can be readily integrated into existing biomolecular NMR methodologies, as demonstrated here for $^1$H-detected relaxation-editing experiments with water suppression. This method provides access to nitrogen's picosecond-modulated quadrupolar interaction via single-scan proton detection in systems that would otherwise yield almost no detectable direct $^{14}$N signal even after averaging over thousands of transients.

physics.chem-ph

Nuclear spin relaxation in zero- to ultralow-field magnetic resonance spectroscopy

Nuclear-magnetic-resonance experiments can interrogate a broad spectrum of molecular-tumbling regimes and can accurately measure interatomic distances in solution with sub-nanometer resolution. In the zero- to ultralow-field (ZULF) regime, population and coherence decay reveal nontrivial behavior due to strong coupling between nuclear spins. We note, in particular, the surprising effects that different resonances show different relaxation rates, depending on (i) the (pre)polarizing magnet field and the shuttling trajectory to the detection region at nano- and microtesla fields, (ii) the strength of the measurement field, (iii) the detection method (single-channel or quadrature), and even (iv) the nutation angle induced by the excitation pulse. We describe herein experimental data of relaxation rates measured for a 13C-labeled formic acid sample, with an atomic-magnetometer-based ZULF setup, and develop a theoretical framework to explain the detected effects and extract molecular properties. The observed effects could be used for spectral assignment, for the establishment of specific motional regimes, for image contrast, and for the characterization of relaxation processes at nano- to microtesla magnetic fields.

physics.chem-ph

Over four minutes relaxation of pyruvate using chemically and physically induced deceleration of relaxation

[1-13C]pyruvate is the most widely used tracer for hyperpolarized metabolic magnetic resonance imaging, with profound applications in tumor and inflammation diagnosis as well as treatment monitoring. The most fundamental hurdle to broader application, however, remains the rapid polarization relaxation and the associated signal loss. Here, we report a method to address this challenge. Studying the nuclear spin relaxation dispersion of [1-13C]pyruvate across magnetic fields from 8 {\mu}T to 9.4 T, as a function of additives, solvents, and preparation methods, allowed us to achieve relaxation times of up to four minutes. Such a long time could enable reliable quality control and nearly polarization loss-free transport, further boosting the power of hyperpolarized metabolic MRI.

physics.chem-ph

Quadrupolar $^{23}$Na$^{+}$ NMR Relaxation as a Probe of Subpicosecond Collective Dynamics in Aqueous Electrolyte Solutions

Nuclear magnetic resonance relaxometry represents a powerful tool for extracting dynamic information. Yet, obtaining links to molecular motion is challenging for many ions that relax through the quadrupolar mechanism, which is mediated by electric field gradient fluctuations and lacks a detailed microscopic description. For sodium ions in aqueous electrolytes, we combine ab initio calculations to account for electron cloud effects with classical molecular dynamics to sample long-time fluctuations, and obtain relaxation rates in good agreement with experiments over broad concentration and temperature ranges. We demonstrate that quadrupolar nuclear relaxation is sensitive to subpicosecond dynamics not captured by previous models based on water reorientation or cluster rotation. While ions affect the overall water retardation, experimental trends are mainly explained by dynamics in the first two solvation shells of sodium, which contain mostly water. This work thus paves the way to the quantitative understanding of quadrupolar relaxation in electrolyte and bioelectrolyte systems.

physics.chem-ph

Battery characterization via eddy-current imaging with nitrogen-vacancy centers in diamond

Sensitive and accurate diagnostic technologies with magnetic sensors are of great importance for identifying and localizing defects of rechargeable solid batteries in a noninvasive detection. We demonstrate a microwave-free AC magnetometry method with negatively charged NV centers in diamond based on a cross-relaxation feature between NV centers and individual substitutional nitrogen (P1) centers occurring at 51.2 mT. We apply the technique to non-destructive solid-state battery imaging. By detecting the eddy-current-induced magnetic field of the battery, we distinguish a defect on the external electrode and identify structural anomalies within the battery body. The achieved spatial resolution is $360\,μ\rm m$. The maximum magnetic field and phase shift generated by the battery at the modulation frequency of 5 kHz are estimated as 0.04 mT and 0.03 rad respectively.

physics.app-ph

Rapid online solid-state battery diagnostics with optically pumped magnetometers

Solid state battery technology is motivated by the desire to deliver flexible power storage in a safe and efficient manner. The increasingly widespread use of batteries from mass-production facilities highlights the need for a rapid and sensitive diagnostic for identifying battery defects. We demonstrate the use of atomic magnetometry to measure the magnetic fields around miniature solid-state battery cells. These fields encode information about battery manufacturing defects, state of charge, impurities, or can provide important insights into ageing processes. Compared with SQUID-based magnetometry, the availability of atomic magnetometers, however, highlights the possibility for a low-cost, portable, and flexible implementation of battery quality-control and characterization technology.

physics.app-ph

Mapping oscillating magnetic fields around rechargeable batteries

Power storage devices such as batteries are a crucial part of modern technology. The development and use of batteries has accelerated in the past decades, yet there are only a few techniques that allow gathering vital information from battery cells in a nonivasive fashion. A widely used technique to investigate batteries is electrical impedance spectroscopy (EIS), which provides information on how the impedance of a cell changes as a function of the frequency of applied alternating currents. Building on recent developments of inside-out MRI (ioMRI), a technique is presented here which produces spatially-resolved maps of the oscillating magnetic fields originating from the alternating electrical currents distributed within a cell. The technique works by using an MRI pulse sequence synchronized with a gated alternating current applied to the cell terminals. The approach is benchmarked with a current-carrying wire coil, and demonstrated with commercial and prototype lithium-ion cells. Marked changes in the fields are observed for different cell types.

physics.app-ph

Battery Diagnostics with Sensitive Magnetometry

The ever-increasing demand for high-capacity rechargeable batteries highlights the need for sensitive and accurate diagnostic technology for determining the state of a cell, for identifying and localizing defects, or for sensing capacity loss mechanisms. Here, we demonstrate the use of atomic magnetometry to map the weak induced magnetic fields around a Li-ion battery cell as a function of state of charge and upon introducing mechanical defects. These measurements provide maps of the magnetic susceptibility of the cell, which follow trends characteristic for the battery materials under study upon discharge. In addition, the measurements reveal hitherto unknown long time-scale transient internal current effects, which were particularly pronounced in the overdischarged regime. The diagnostic power of this technique is promising for the assessment of cells in research, quality control, or during operation, and could help uncover details of charge storage and failure processes in cells.

physics.app-ph

Multinuclear Absolute MR Thermometry

Non-invasive measurement of absolute temperature is important for proper characterization of various pathologies and for evaluation of thermal dose during interventional procedures. The proton magnetic resonance (MR) frequency shift method can be used to map relative temperature changes in tissues; however, spatiotemporal variations in the main magnetic field and the lack of an internal frequency reference at each location challenge the determination of absolute temperature. Here, we introduce a novel multinuclear method for absolute MR thermometry, based on the fact that the proton and sodium nuclei exhibit a unique and distinct characteristic frequency dependence with temperature. A one-to-one mapping between the precession frequency difference of the two nuclei and absolute temperature is demonstrated. Proof-of-concept experiments were conducted in aqueous solutions with different NaCl concentrations, in agarose gel samples, and in freshly excised ex vivo mouse tissues. One-dimensional chemical shift imaging was also conducted at two steady-state temperatures, demonstrating excellent agreement with infrared measurements.

physics.med-ph

Aspects of NMR Reciprocity and Applications in Highly Conductive Media

In the context of NMR spectroscopy and MRI, the principle of reciprocity provides a convenient method for determining the reception sensitivity from the transmitted rf field pattern. The reciprocity principle for NMR was originally described by Hoult et al. [J. Magn. Reson. (1976),24, 71], and can be seen as being based on the broader Lorentz reciprocity principle, and similar theorems from antenna theory. One frequent application of the reciprocity principle is that for a single coil used for both transmission and detection, the transmit and receive fields can be assumed to be equal. This aspect is also where some of the conceptual difficulty of applying the theorem may be encountered. For example, the questions of whether one should use the complex conjugate field for detection, or whether one should apply the theorem in the rotating frame or the laboratory frame are often where considerable confusion may arise, and incorrect results may be derived. We attempt here to provide a helpful discussion of the application of the reciprocity principle in such a way as to clarify some of the confounding questions. In particular, we avoid the use of the `negatively rotating frame', which is frequently mentioned in this context, since we consider it to unnecessarily complicate the matter. In addition, we also discuss the implications of the theorem for magnetic resonance experiments on conducting samples, and metals, in particular.

physics.app-ph

Visualizing Skin Effects in Conductors with MRI: ${}^7$Li MRI Experiments and Calculations

While experiments on metals have been performed since the early days of NMR (and DNP), the use of bulk metal is normally avoided. Instead, often powders have been used in combination with low fields, so that skin depth effects could be neglected. Another complicating factor of acquiring NMR spectra or MRI images of bulk metal is the strong signal dependence on the orientation between the sample and the radio frequency (RF) coil, leading to non-intuitive image distortions and inaccurate quantification. Such factors are particularly important for NMR and MRI of batteries and other electrochemical devices. Here, we show results from a systematic study combining RF field calculations with experimental MRI of $^7$Li metal to visualize skin depth effects directly and to analyze the RF field orientation effect on MRI of bulk metal. It is shown that a certain degree of selectivity can be achieved for particular faces of the metal, simply based on the orientation of the sample. By combining RF field calculations with bulk magnetic susceptibility calculations accurate NMR spectra can be obtained from first principles. Such analyses will become valuable in many applications involving battery systems, but also metals, in general.

cond-mat.mtrl-sci

Noise and Spin-noise: Cable dependence of Optimal Tuning/Matching Conditions

Previous studies have shown that tuning/matching conditions optimized for transmission and detection can be significantly different for a variety of commercial NMR probes. In addition, it was also shown that by optimizing reception tuning (as opposed to typical transmission or reflection tuning) one may in some cases obtain sensitivity enhancements by as much as 25-50%. In earlier work, spin-noise and absorbed circuit noise signals have also been used to characterize reception optima. In this work, we show how the length of the coaxial transmission line cable between the pre-amplifier and the probe affects the positions of the reception tuning optimum, the radiation damping strength, induced frequency shifts, as well as, the shape of the spin-noise and absorbed circuit noise line shapes.

physics.ins-det

Long Lived NMR Signal in Bone

Solids and rigid tissues such as bone, ligaments, and tendons, typically appear dark in magnetic resonance imaging (MRI), which is due to the extremely short-lived proton nuclear magnetic resonance (NMR) signals. This short lifetime is due to strong dipolar interactions between immobilized proton spins, which render it challenging to detect these signals with sufficient resolution and sensitivity. Here we show the possibility of exciting long-lived signals in cortical bone tissue with a signature consistent with that of bound water signals. Contrary to long-standing belief, it is further shown that dipolar coupling networks are an integral requirement for the excitation of these long-lived signals. The use of these signals could enhance the ability to visualize rigid tissues and solid samples with high sensitivity, resolution, and specificity via MRI.

physics.med-ph

Cutoff-Free Traveling Wave NMR

Recently, the concept of traveling-wave NMR/MRI was introduced by Brunner et al. (Nature 457, 994-992 (2009)), who demonstrated MR images acquired using radio frequency (RF) waves propagating down the bore of an MR scanner. One of the significant limitations of this approach is that each bore has a specific cutoff frequency, which can be higher than most Larmor frequencies of at the magnetic field strengths commonly in use for MR imaging and spectroscopy today. We overcome this limitation by using a central conductor in the waveguide and thereby converting it to a transmission line (TL), which has no cutoff frequency. Broadband propagation of waves through the sample thus becomes possible. NMR spectra and images with such an arrangement are presented and genuine traveling wave behavior is demonstrated. In addition to facilitating NMR spectroscopy and imaging in smaller bores via traveling waves, this approach also allows one to perform multinuclear traveling wave experiments (an example of which is shown), and to study otherwise difficult-to-access samples in unusual geometries.

physics.ins-det