SearcharxivSearch

arXiv subjects

Alexis C. Weber

Publications and source records attributed to Alexis C. Weber.

5 recordsLinked to original sources

BICEP/Keck XXI: Constraints on Early-Universe Parity Violation from Multipole-Dependent Birefringence

We present the first constraints on multipole-dependent cosmic birefringence using CMB polarization data from the BK18 dataset, which combines observations from BICEP2, Keck Array, and BICEP3 at frequencies of 95, 150, and 220 GHz. Photon coupling to an axion-like field leads to the rotation of CMB polarization, inducing non-zero EB cross-correlations. We show that a multipole-dependent rotation beta(l) imprints a distinct signature in the polarization spectra that can be constrained. Specifically, we consider an Early Dark Energy (EDE) scenario in which a pseudoscalar field couples to photons through a Chern-Simons interaction, generating a polarization rotation with multipole dependence. We introduce a phenomenological beta(l) as a step function, obtaining constraints on the step function size consistent with zero, with uncertainties less than 0.15 degrees (68% CL). In addition, using multi-frequency EE, BB, and EB cross-spectra, along with robust BICEP/Keck foreground treatment and likelihood framework, we derive constraints on the axion-photon coupling amplitude g for several choices of EDE parameters. For the baseline best-fit value f_{EDE} = 0.087 from the Planck 2018 analysis, we obtain g = 0.11 +/- 0.37 (68% CL), consistent with previous limits.

astro-ph.CO

Calibration Measurements of the BICEP3 and BICEP Array CMB Polarimeters from 2017 to 2024

The BICEP3 and BICEP Array polarimeters are small-aperture refracting telescopes located at the South Pole designed to measure primordial gravitational wave signatures in the Cosmic Microwave Background (CMB) polarization, predicted by inflation. Constraining the inflationary signal requires not only excellent sensitivity, but also careful control of instrumental systematics. Both instruments use antenna-coupled orthogonally polarized detector pairs, and the polarized sky signal is reconstructed by taking the difference in each detector pair. As a result, the differential response between detectors within a pair becomes an important systematic effect we must control. Additionally, mapping the intensity and polarization response in regions away from the main beam can inform how sidelobe levels affect CMB measurements. Extensive calibration measurements are taken in situ every austral summer for control of instrumental systematics and instrument characterisation. In this work, we detail the set of beam calibration measurements that we conduct on the BICEP receivers, from deep measurements of main beam response to polarized beam response and sidelobe mapping. We discuss the impact of these measurements for instrumental systematics studies and design choices for future CMB receivers.

astro-ph.CO

Design and Performance of 30/40 GHz Diplexed Focal Plane for BICEP Array

We demonstrate a wide-band diplexed focal plane suitable for observing low-frequency foregrounds that are important for cosmic microwave background polarimetry. The antenna elements are composed of slotted bowtie antennas with 60% bandwidth that can be partitioned into two bands. Each pixel is composed of two interleaved 12$\times$12 pairs of linearly polarized antenna elements forming a phased array, designed to synthesize a symmetric beam with no need for focusing optics. The signal from each antenna element is captured in-phase and uniformly weighted by a microstrip summing tree. The antenna signal is diplexed into two bands through the use of two complementary, six-pole Butterworth filters. This filter architecture ensures a contiguous impedance match at all frequencies, and thereby achieves minimal reflection loss between both bands. Subsequently, out-of-band rejection is increased with a bandpass filter and the signal is then deposited on a transition-edge sensor bolometer island. We demonstrate the performance of this focal plane with two distinct bands, 30 and 40 GHz, each with a bandwidth of $\sim$20 and 15 GHz, respectively. The unequal bandwidths between the two bands are caused by an unintentional shift in diplexer frequency from its design values. The end-to-end optical efficiency of these detectors are relatively modest, at 20-30%, with an efficiency loss due to an unknown impedance mismatch in the summing tree. Far-field beam maps show good optical characteristics with edge pixels having no more than $\sim$ 5% ellipticity and $\sim$10-15% peak-to-peak differences for A-B polarization pairs.

astro-ph.IM

Plastic Laminate Antireflective Coatings for Millimeter-wave Optics in BICEP Array

The BICEP/Keck series of experiments target the Cosmic Microwave Background at degree-scale resolution from the South Pole. Over the next few years, the "Stage-3" BICEP Array (BA) telescope will improve the program's frequency coverage and sensitivity to primordial B-mode polarization by an order of magnitude. The first receiver in the array, BA1, began observing at 30/40 GHz in early 2020. The next two receivers, BA2 and BA3, are currently being assembled and will map the southern sky at frequencies ranging from 95 GHz to 150 GHz. Common to all BA receivers is a refractive, on-axis, cryogenic optical design that focuses microwave radiation onto a focal plane populated with antenna-coupled bolometers. High-performance antireflective coatings up to 760 mm in aperture are needed for each element in the optical chain, and must withstand repeated thermal cycles down to 4 K. Here we present the design and fabrication of the 30/40 GHz anti-reflection coatings for the recently deployed BA1 receiver, then discuss laboratory measurements of their reflectance. We review the lamination method for these single- and dual-layer plastic coatings with indices matched to various polyethylene, nylon and alumina optics. We also describe ongoing efforts to optimize coatings for the next BA cryostats, which may inform technological choices for future Small-Aperture Telescopes of the CMB "Stage 4" experiment.

astro-ph.IM

Pointing control for the SPIDER balloon-borne telescope

We present the technology and control methods developed for the pointing system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed to detect the imprint of primordial gravitational waves in the polarization of the Cosmic Microwave Background radiation. We describe the two main components of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A 13 kHz PI control loop runs on a digital signal processor, with feedback from fibre optic rate gyroscopes. This system can control azimuthal speed with < 0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven linear actuators to rotate the cryostat, which houses the optical instruments, relative to the outer frame. With the velocity in each axis controlled in this way, higher-level control loops on the onboard flight computers can implement the pointing and scanning observation modes required for the experiment. We have accomplished the non-trivial task of scanning a 5000 lb payload sinusoidally in azimuth at a peak acceleration of 0.8 deg/s$^2$, and a peak speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing control accuracy.

astro-ph.IM