Follow Your Heart: Landmark-Guided Transducer Pose Scoring for Point-of-Care Echocardiography

Point-of-care transthoracic echocardiography (TTE) makes it possible to assess a patient's cardiac function in almost any setting. A critical step in the TTE exam is acquisition of the apical 4-chamber (A4CH) view, which is used to evaluate clinically impactful measurements such as left ventricular ejection fraction (LVEF). However, optimizing transducer pose for high-quality image acquisition and subsequent measurement is a challenging task, particularly for novice users. In this work, we present a multi-task network that provides feedback cues for A4CH view acquisition and automatically estimates LVEF in high-quality A4CH images. The network cascades a transducer pose scoring module and an uncertainty-aware LV landmark detector with automated LVEF estimation. A strength is that network training and inference do not require cumbersome or costly setups for transducer position tracking. We evaluate performance on point-of-care TTE data acquired with a spatially dense "sweep" protocol around the optimal A4CH view. The results demonstrate the network's ability to determine when the transducer pose is on target, close to target, or far from target based on the images alone, while generating visual landmark cues that guide anatomical interpretation and orientation. In conclusion, we demonstrate a promising strategy to provide guidance for A4CH view acquisition, which may be useful when deploying point-of-care TTE in limited resource settings.

cs.CV

A geometric feature tracking approach for noninvasive patient specific estimation of leaflet strain from 3D images of heart valves

Valvular heart disease is prevalent and a major contributor to heart failure. Valve leaflet strain is a promising metric for evaluating the mechanics underlying the initiation and progression of valvular pathology. However, generalizable methods for noninvasively quantifying valvular strain from clinically acquired patient images remain limited. To address this limitation, we developed a geometric feature-tracking framework to quantify in vivo leaflet strain from 3DE images. The method integrates a cohort-derived geometric reference atlas to establish geometric correspondence and introduces a novel distance-weighted coherent point drift algorithm for non-rigid registration. We evaluated performance against a finite element benchmark model and compared the approach with conventional point-based tracking methods. The framework was applied to pediatric and adult patient datasets (N = 31) across variable valve morphologies. The proposed method demonstrated greater accuracy in quantifying anatomical alignment and leaflet strain than conventional point-based approaches. Validation against the finite element benchmark confirmed improved strain estimation. The framework achieved reliable inter-phase tracking of valve deformation across diverse morphologies in pediatric and adult patients. Analysis identified a consistent distribution pattern of the 1st principal strain associated with leaflet billow (prolapse). This feature-tracking framework provides a generalizable method for noninvasive quantification of atrioventricular valve leaflet strain from clinical 3DE images. Characterization of biomechanical strain patterns may improve prognostic assessment and support longitudinal evaluation of valvular heart disease. Further investigation of the biomechanical signatures of heart valve disease has the potential to enhance prognostic assessment and longitudinal evaluation of valvular heart disease.

q-bio.QM

Towards Patient-Specific Surgical Planning for Bicuspid Aortic Valve Repair: Fully Automated Segmentation of the Aortic Valve in 4D CT

The bicuspid aortic valve (BAV) is the most prevalent congenital heart defect and may require surgery for complications such as stenosis, regurgitation, and aortopathy. BAV repair surgery is effective but challenging due to the heterogeneity of BAV morphology. Multiple imaging modalities can be employed to assist the quantitative assessment of BAVs for surgical planning. Contrast-enhanced 4D computed tomography (CT) produces volumetric temporal sequences with excellent contrast and spatial resolution. Segmentation of the aortic cusps and root in these images is an essential step in creating patient specific models for visualization and quantification. While deep learning-based methods are capable of fully automated segmentation, no BAV-specific model exists. Among valve segmentation studies, there has been limited quantitative assessment of the clinical usability of the segmentation results. In this work, we developed a fully automated multi-label BAV segmentation pipeline based on nnU-Net. The predicted segmentations were used to carry out surgically relevant morphological measurements including geometric cusp height, commissural angle and annulus diameter, and the results were compared against manual segmentation. Automated segmentation achieved average Dice scores of over 0.7 and symmetric mean distance below 0.7 mm for all three aortic cusps and the root wall. Clinically relevant benchmarks showed good consistency between manual and predicted segmentations. Overall, fully automated BAV segmentation of 3D frames in 4D CT can produce clinically usable measurements for surgical risk stratification, but the temporal consistency of segmentations needs to be improved.

eess.IV

ADEPT: A Noninvasive Method for Determining Elastic Parameters of Valve Tissue

Computer simulation of "virtual interventions" may inform optimal valve repair for a given patient prior to intervention. However, the paucity of noninvasive methods to determine in vivo mechanical parameters of valves limits the accuracy of computer prediction and their clinical application. To address this, we propose ADEPT: A noninvasive method for Determining Elastic Parameters of valve Tissue. In this work, we demonstrated its application to the tricuspid valve of a child. We first tracked valve displacements from open to closed frames within a 3D echocardiogram time sequence using image registration. Physics-informed neural networks were subsequently applied to estimate the nonlinear mechanical properties from first principles and reference displacements. The simulated model using these patient-specific parameters closely aligned with the reference image segmentation, achieving a mean symmetric distance of less than 1 mm. Our approach doubled the accuracy of the simulated model compared to the generic parameters reported in the literature.

q-bio.QM