SearcharxivSearch

arXiv subjects

Alistair Young

Publications and source records attributed to Alistair Young.

16 recordsLinked to original sources

Learning Cardiac Motion Priors for Implicit Neural Representations

Implicit neural representations (INRs) are well suited to cardiac motion estimation, providing continuous, compact representations of motion fields. However, fitting an INR to each image sequence is time-consuming and sensitive to the optimisation trajectory. Learned priors can help guide optimisation towards plausible motion fields and enable faster adaptation, but learning priors for cardiac motion INRs remains under-explored. In this work, we compare four strategies for learning cardiac motion priors, including a population prior learned by joint optimisation, a consensus prior obtained by weight averaging, auto-decoders, and meta-learning. Using short-axis tagged cardiac magnetic resonance images from the UK Biobank, we evaluate their impact on tracking accuracy, motion behaviour, and adaptation trajectory. All learned priors substantially improved early adaptation performance compared with random initialisation. While the simple consensus prior was effective, auto-decoders recovered large deformations faster during early adaptation. Meta-learning achieved strong early performance and maintained the best adaptation trajectory over 50 iterations. The code can be found at https://github.com/andrewjackbell/nvf_priors .

cs.CV

Enabling Ultra-Fast Cardiovascular Imaging Across Heterogeneous Clinical Environments with A Generalist Foundation Model and Multimodal Database

Multimodal cardiovascular magnetic resonance (CMR) imaging provides comprehensive and non-invasive insights into cardiovascular disease (CVD) diagnosis and underlying mechanisms. Despite decades of advancements, its widespread clinical adoption remains constrained by prolonged scan times, inconsistent image quality, and heterogeneity across medical environments. This underscores the urgent need for a generalist reconstruction foundation model for ultra-fast CMR imaging, one formulated for physics-constrained inverse problems in the sensor (k-space) domain, capable of adapting across diverse imaging scenarios and serving as the essential substrate for all downstream analyses. To enable this goal, we curate MMCMR-427K, the largest and most comprehensive multimodal CMR k-space database to date, comprising 427,465 multi-coil k-space data paired with structured metadata across 13 international centers, 12 CMR modalities, 15 scanners spanning four field strengths, and 17 CVD categories in populations across three continents. Building on this unprecedented resource, we introduce CardioMM, a generalist reconstruction foundation model capable of dynamically adapting to heterogeneous fast CMR imaging scenarios. CardioMM unifies semantic contextual understanding with physics-informed data consistency to deliver robust reconstructions across varied scanners, protocols, and patient presentations. Comprehensive evaluations demonstrate that CardioMM achieves state-of-the-art performance across internal centers and exhibits strong zero-shot generalization to unseen external settings. Importantly, CardioMM supports acceleration up to 24x, providing the first evidence that such extreme acquisition speed can preserve key cardiac phenotypes, quantitative myocardial biomarkers, and diagnostic image quality without compromising clinical integrity.

eess.IV

MorphiNet: A Graph Subdivision Network for Adaptive Bi-ventricle Surface Reconstruction

Cardiac Magnetic Resonance (CMR) imaging is widely used for heart model reconstruction and digital twin computational analysis because of its ability to visualize soft tissues and capture dynamic functions. However, CMR images have an anisotropic nature, characterized by large inter-slice distances and misalignments from cardiac motion. These limitations result in data loss and measurement inaccuracies, hindering the capture of detailed anatomical structures. In this work, we introduce MorphiNet, a novel network that reproduces heart anatomy learned from high-resolution Computed Tomography (CT) images, unpaired with CMR images. MorphiNet encodes the anatomical structure as gradient fields, deforming template meshes into patient-specific geometries. A multilayer graph subdivision network refines these geometries while maintaining a dense point correspondence, suitable for computational analysis. MorphiNet achieved state-of-the-art bi-ventricular myocardium reconstruction on CMR patients with tetralogy of Fallot with 0.3 higher Dice score and 2.6 lower Hausdorff distance compared to the best existing template-based methods. While matching the anatomical fidelity of comparable neural implicit function methods, MorphiNet delivered 50$\times$ faster inference. Cross-dataset validation on the Automated Cardiac Diagnosis Challenge confirmed robust generalization, achieving a 0.7 Dice score with 30\% improvement over previous template-based approaches. We validate our anatomical learning approach through the successful restoration of missing cardiac structures and demonstrate significant improvement over standard Loop subdivision. Motion tracking experiments further confirm MorphiNet's capability for cardiac function analysis, including accurate ejection fraction calculation that correctly identifies myocardial dysfunction in tetralogy of Fallot patients.

eess.IV

Towards Modality- and Sampling-Universal Learning Strategies for Accelerating Cardiovascular Imaging: Summary of the CMRxRecon2024 Challenge

Cardiovascular health is vital to human well-being, and cardiac magnetic resonance (CMR) imaging is considered the {clinical reference standard} for diagnosing cardiovascular disease. However, its adoption is hindered by long scan times, complex contrasts, and inconsistent quality. While deep learning methods perform well on specific CMR imaging {sequences}, they often fail to generalize across modalities and sampling schemes. The lack of benchmarks for high-quality, fast CMR image reconstruction further limits technology comparison and adoption. The CMRxRecon2024 challenge, attracting over 200 teams from 18 countries, addressed these issues with two tasks: generalization to unseen {modalities} and robustness to diverse undersampling patterns. We introduced the largest public multi-{modality} CMR raw dataset, an open benchmarking platform, and shared code. Analysis of the best-performing solutions revealed that prompt-based adaptation and enhanced physics-driven consistency enabled strong cross-scenario performance. These findings establish principles for generalizable reconstruction models and advance clinically translatable AI in cardiovascular imaging.

eess.IV

Personalized 3D Myocardial Infarct Geometry Reconstruction from Cine MRI with Explicit Cardiac Motion Modeling

Accurate representation of myocardial infarct geometry is crucial for patient-specific cardiac modeling in MI patients. While Late gadolinium enhancement (LGE) MRI is the clinical gold standard for infarct detection, it requires contrast agents, introducing side effects and patient discomfort. Moreover, infarct reconstruction from LGE often relies on sparsely sampled 2D slices, limiting spatial resolution and accuracy. In this work, we propose a novel framework for automatically reconstructing high-fidelity 3D myocardial infarct geometry from 2D clinically standard cine MRI, eliminating the need for contrast agents. Specifically, we first reconstruct the 4D biventricular mesh from multi-view cine MRIs via an automatic deep shape fitting model, biv-me. Then, we design a infarction reconstruction model, CMotion2Infarct-Net, to explicitly utilize the motion patterns within this dynamic geometry to localize infarct regions. Evaluated on 205 cine MRI scans from 126 MI patients, our method shows reasonable agreement with manual delineation. This study demonstrates the feasibility of contrast-free, cardiac motion-driven 3D infarct reconstruction, paving the way for efficient digital twin of MI.

eess.IV

Cardiac Digital Twins at Scale from MRI: Open Tools and Representative Models from ~55000 UK Biobank Participants

A cardiac digital twin is a virtual replica of a patient's heart for screening, diagnosis, prognosis, risk assessment, and treatment planning of cardiovascular diseases. This requires an anatomically accurate patient-specific 3D structural representation of the heart, suitable for electro-mechanical simulations or study of disease mechanisms. However, generation of cardiac digital twins at scale is demanding and there are no public repositories of models across demographic groups. We describe an automatic open-source pipeline for creating patient-specific left and right ventricular meshes from cardiovascular magnetic resonance images, its application to a large cohort of ~55000 participants from UK Biobank, and the construction of the most comprehensive cohort of adult heart models to date, comprising 1423 representative meshes across sex (male, female), body mass index (range: 16 - 42 kg/m$^2$) and age (range: 49 - 80 years). Our code is available at https://github.com/cdttk/biv-volumetric-meshing/tree/plos2025 , and pre-trained networks, representative volumetric meshes with fibers and UVCs will be made available soon.

eess.IV

In Silico Trials for Sex-Specific patient Inclusion Criteria in Cardiac Resynchronization Therapy: Advancing Precision in Heart Failure Treatment

Cardiac resynchronization therapy (CRT) guidelines are based on clinical trials with limited female representation and inconsistent left bundle branch block (LBBB) definitions. Conventional QRS duration (QRSd) criteria show variable diagnostic accuracy between sexes, partly due to differences in heart size and remodeling. We evaluated the influence of sex, heart size, LBBB, and conduction delay on QRSd and assessed the diagnostic performance of conventional and indexed QRSd criteria using a population-based modelling approach. Simulated QRSd were derived from electrophysiological simulations conducted in 2627 UK Biobank healthy participants and 359 patients with ischemic heart disease, by modelling LBBB and normal activation combined with/without conduction delay. QRSd criteria under-selected LBBB females and over-selected non-LBBB patients. Indexing by LVEDV and LV mass reduced sex disparities but increased the over-selection in non-LBBB patients. Height-indexed QRSd effectively resolved sex differences and maintained low non-LBBB selection rates, demonstrating superior performance and potential for more equitable CRT selection.

physics.med-ph

A Computational Pipeline for Advanced Analysis of 4D Flow MRI in the Left Atrium

The left atrium (LA) plays a pivotal role in modulating left ventricular filling, but our comprehension of its hemodynamics is significantly limited by the constraints of conventional ultrasound analysis. 4D flow magnetic resonance imaging (4D Flow MRI) holds promise for enhancing our understanding of atrial hemodynamics. However, the low velocities within the LA and the limited spatial resolution of 4D Flow MRI make analyzing this chamber challenging. Furthermore, the absence of dedicated computational frameworks, combined with diverse acquisition protocols and vendors, complicates gathering large cohorts for studying the prognostic value of hemodynamic parameters provided by 4D Flow MRI. In this study, we introduce the first open-source computational framework tailored for the analysis of 4D Flow MRI in the LA, enabling comprehensive qualitative and quantitative analysis of advanced hemodynamic parameters. Our framework proves robust to data from different centers of varying quality, producing high-accuracy automated segmentations (Dice $>$ 0.9 and Hausdorff 95 $<$ 3 mm), even with limited training data. Additionally, we conducted the first comprehensive assessment of energy, vorticity, and pressure parameters in the LA across a spectrum of disorders to investigate their potential as prognostic biomarkers.

cs.CV

CMRxRecon2024: A Multi-Modality, Multi-View K-Space Dataset Boosting Universal Machine Learning for Accelerated Cardiac MRI

Cardiac magnetic resonance imaging (MRI) has emerged as a clinically gold-standard technique for diagnosing cardiac diseases, thanks to its ability to provide diverse information with multiple modalities and anatomical views. Accelerated cardiac MRI is highly expected to achieve time-efficient and patient-friendly imaging, and then advanced image reconstruction approaches are required to recover high-quality, clinically interpretable images from undersampled measurements. However, the lack of publicly available cardiac MRI k-space dataset in terms of both quantity and diversity has severely hindered substantial technological progress, particularly for data-driven artificial intelligence. Here, we provide a standardized, diverse, and high-quality CMRxRecon2024 dataset to facilitate the technical development, fair evaluation, and clinical transfer of cardiac MRI reconstruction approaches, towards promoting the universal frameworks that enable fast and robust reconstructions across different cardiac MRI protocols in clinical practice. To the best of our knowledge, the CMRxRecon2024 dataset is the largest and most protocal-diverse publicly available cardiac k-space dataset. It is acquired from 330 healthy volunteers, covering commonly used modalities, anatomical views, and acquisition trajectories in clinical cardiac MRI workflows. Besides, an open platform with tutorials, benchmarks, and data processing tools is provided to facilitate data usage, advanced method development, and fair performance evaluation.

eess.IV

Goal-conditioned reinforcement learning for ultrasound navigation guidance

Transesophageal echocardiography (TEE) plays a pivotal role in cardiology for diagnostic and interventional procedures. However, using it effectively requires extensive training due to the intricate nature of image acquisition and interpretation. To enhance the efficiency of novice sonographers and reduce variability in scan acquisitions, we propose a novel ultrasound (US) navigation assistance method based on contrastive learning as goal-conditioned reinforcement learning (GCRL). We augment the previous framework using a novel contrastive patient batching method (CPB) and a data-augmented contrastive loss, both of which we demonstrate are essential to ensure generalization to anatomical variations across patients. The proposed framework enables navigation to both standard diagnostic as well as intricate interventional views with a single model. Our method was developed with a large dataset of 789 patients and obtained an average error of 6.56 mm in position and 9.36 degrees in angle on a testing dataset of 140 patients, which is competitive or superior to models trained on individual views. Furthermore, we quantitatively validate our method's ability to navigate to interventional views such as the Left Atrial Appendage (LAA) view used in LAA closure. Our approach holds promise in providing valuable guidance during transesophageal ultrasound examinations, contributing to the advancement of skill acquisition for cardiac ultrasound practitioners.

cs.CV

Cardiac ultrasound simulation for autonomous ultrasound navigation

Ultrasound is well-established as an imaging modality for diagnostic and interventional purposes. However, the image quality varies with operator skills as acquiring and interpreting ultrasound images requires extensive training due to the imaging artefacts, the range of acquisition parameters and the variability of patient anatomies. Automating the image acquisition task could improve acquisition reproducibility and quality but training such an algorithm requires large amounts of navigation data, not saved in routine examinations. Thus, we propose a method to generate large amounts of ultrasound images from other modalities and from arbitrary positions, such that this pipeline can later be used by learning algorithms for navigation. We present a novel simulation pipeline which uses segmentations from other modalities, an optimized volumetric data representation and GPU-accelerated Monte Carlo path tracing to generate view-dependent and patient-specific ultrasound images. We extensively validate the correctness of our pipeline with a phantom experiment, where structures' sizes, contrast and speckle noise properties are assessed. Furthermore, we demonstrate its usability to train neural networks for navigation in an echocardiography view classification experiment by generating synthetic images from more than 1000 patients. Networks pre-trained with our simulations achieve significantly superior performance in settings where large real datasets are not available, especially for under-represented classes. The proposed approach allows for fast and accurate patient-specific ultrasound image generation, and its usability for training networks for navigation-related tasks is demonstrated.

eess.IV

The Impact of Domain Shift on Left and Right Ventricle Segmentation in Short Axis Cardiac MR Images

Domain shift refers to the difference in the data distribution of two datasets, normally between the training set and the test set for machine learning algorithms. Domain shift is a serious problem for generalization of machine learning models and it is well-established that a domain shift between the training and test sets may cause a drastic drop in the model's performance. In medical imaging, there can be many sources of domain shift such as different scanners or scan protocols, different pathologies in the patient population, anatomical differences in the patient population (e.g. men vs women) etc. Therefore, in order to train models that have good generalization performance, it is important to be aware of the domain shift problem, its potential causes and to devise ways to address it. In this paper, we study the effect of domain shift on left and right ventricle blood pool segmentation in short axis cardiac MR images. Our dataset contains short axis images from 4 different MR scanners and 3 different pathology groups. The training is performed with nnUNet. The results show that scanner differences cause a greater drop in performance compared to changing the pathology group, and that the impact of domain shift is greater on right ventricle segmentation compared to left ventricle segmentation. Increasing the number of training subjects increased cross-scanner performance more than in-scanner performance at small training set sizes, but this difference in improvement decreased with larger training set sizes. Training models using data from multiple scanners improved cross-domain performance.

eess.IV

Quality-aware Cine Cardiac MRI Reconstruction and Analysis from Undersampled k-space Data

Cine cardiac MRI is routinely acquired for the assessment of cardiac health, but the imaging process is slow and typically requires several breath-holds to acquire sufficient k-space profiles to ensure good image quality. Several undersampling-based reconstruction techniques have been proposed during the last decades to speed up cine cardiac MRI acquisition. However, the undersampling factor is commonly fixed to conservative values before acquisition to ensure diagnostic image quality, potentially leading to unnecessarily long scan times. In this paper, we propose an end-to-end quality-aware cine short-axis cardiac MRI framework that combines image acquisition and reconstruction with downstream tasks such as segmentation, volume curve analysis and estimation of cardiac functional parameters. The goal is to reduce scan time by acquiring only a fraction of k-space data to enable the reconstruction of images that can pass quality control checks and produce reliable estimates of cardiac functional parameters. The framework consists of a deep learning model for the reconstruction of 2D+t cardiac cine MRI images from undersampled data, an image quality-control step to detect good quality reconstructions, followed by a deep learning model for bi-ventricular segmentation, a quality-control step to detect good quality segmentations and automated calculation of cardiac functional parameters. To demonstrate the feasibility of the proposed approach, we perform simulations using a cohort of selected participants from the UK Biobank (n=270), 200 healthy subjects and 70 patients with cardiomyopathies. Our results show that we can produce quality-controlled images in a scan time reduced from 12 to 4 seconds per slice, enabling reliable estimates of cardiac functional parameters such as ejection fraction within 5% mean absolute error.

eess.IV

4DFlowNet: Super-Resolution 4D Flow MRI using Deep Learning and Computational Fluid Dynamics

4D-flow magnetic resonance imaging (MRI) is an emerging imaging technique where spatiotemporal 3D blood velocity can be captured with full volumetric coverage in a single non-invasive examination. This enables qualitative and quantitative analysis of hemodynamic flow parameters of the heart and great vessels. An increase in the image resolution would provide more accuracy and allow better assessment of the blood flow, especially for patients with abnormal flows. However, this must be balanced with increasing imaging time. The recent success of deep learning in generating super resolution images shows promise for implementation in medical images. We utilized computational fluid dynamics simulations to generate fluid flow simulations and represent them as synthetic 4D flow MRI data. We built our training dataset to mimic actual 4D flow MRI data with its corresponding noise distribution. Our novel 4DFlowNet network was trained on this synthetic 4D flow data and was capable in producing noise-free super resolution 4D flow phase images with upsample factor of 2. We also tested the 4DFlowNet in actual 4D flow MR images of a phantom and normal volunteer data, and demonstrated comparable results with the actual flow rate measurements giving an absolute relative error of 0.6 to 5.8% and 1.1 to 3.8% in the phantom data and normal volunteer data, respectively.

eess.IV

Investigation of renormalization group methods for the numerical simulation of isotropic turbulence

Renormalization group has enjoyed successes in other areas of statistical physics. However, its application to turbulence faces several technical difficulties, which have had to be circumvented by uncontrolled approximations. Indeed, in view of the deterministic nature of the Navier-Stokes equations, it is clear that the operation of averaging out the high-wavenumber modes while keeping the low-wavenumber modes constant, cannot be done rigorously and in itself can only be an approximation. With points like this in mind, we have recently adopted direct numerical simulation as a tool for probing the basic feasibility of using RG techniques to reduce the number of degrees of freedom requiring to be numerically simulated. In this paper, we present some of the first results of this approach.

physics.flu-dyn

Explict-scales projections of the partitioned non-linear term in direct numerical simulation of the Navier-Stokes equation

In this paper we consider the properties of the internal partitions of the nonlinear term, obtained when a filter with a sharp cutoff is introduced in wavenumber space. We see what appears to be some degree of independence of the choice of the position of the cutoff wavenumber for both instantaneous and time-integrated partitioned nonlinearities. We also investigate the basic idea of an eddy-viscosity model for subgrid terms and have found that while phase modelling will be very poor, amplitude modelling can be far more successful.

physics.flu-dyn