Searcharxiv⌕ Search

arXiv subjects

Amir Khodabakhsh

Publications and source records attributed to Amir Khodabakhsh.

10 recordsLinked to original sources

Multi-species breath biomarker profiling with an ultra-broadband (2.9-11.5 μm) spectroscopic platform

Online, comprehensive molecular profiling of exhaled breath provides a non-invasive window into human metabolism, yet current optical platforms are restricted by narrow instantaneous spectral coverage. Here, we present a novel ultra-broadband mid-infrared spectroscopic platform that enables simultaneous, high-sensitivity detection of a comprehensive profile of breath biomarkers. By integrating an intrapulse difference-frequency generation (IDFG) supercontinuum source spanning 2.9-11.5 $μ$m (2580 cm$^{-1}$) with a custom-built Fourier transform spectrometer, we achieve a spectral resolution of 0.1 cm$^{-1}$ - surpassing current laser-based approaches. Combined with a standardized online sampling system, the platform achieves sensitivities in the tens of parts per billion over three minutes, resolving dynamic metabolic changes of ammonia, methane, isoprene, acetone, carbon monoxide, and nitrous oxide. We demonstrate the system's utility through proof-of-concept case studies tracking responses to fasting, protein intake, and smoking. This calibration-free platform establishes a powerful and versatile tool for online breath analysis, with broad potential in clinical diagnostics and exposure monitoring.

physics.optics↗

Time-resolved mid-infrared dual-comb spectroscopy

Dual-comb spectroscopy can provide broad spectral bandwidth and high spectral resolution in a short acquisition time, enabling time-resolved measurements. Specifically, spectroscopy in the mid-infrared wavelength range is of particular interest, since most of the molecules have their strongest rotational-vibrational transitions in this "fingerprint" region. Here we report time-resolved mid-infrared dual-comb spectroscopy for the first time, covering ~300 nm bandwidth around 3.3 μm with 6 GHz spectral resolution and 20 μs temporal resolution. As a demonstration, we study a CH4/He gas mixture in an electric discharge, while the discharge is modulated between dark and glow regimes. We simultaneously monitor the production of C2H6 and the vibrational excitation of CH4 molecules, observing the dynamics of both processes. This approach to broadband, high-resolution, and time-resolved mid-infrared spectroscopy provides a new tool for monitoring the kinetics of fast chemical reactions, with potential applications in various fields such as physical chemistry and plasma/combustion analysis.

physics.app-ph↗

An experimental water line list at 1950 K in the 6250 -- 6670 \cm\ region

An absorption spectrum of H$_2$$^{16}$O at 1950 K is recorded in a premixed methane/air flat flame using a cavity-enhanced optical frequency comb-based Fourier transform spectrometer. 2417 absorption lines are identified in the 6250 -- 6670 cm region with an accuracy of about 0.01 cm. Absolute line intensities are retrieved using temperature and concentration values obtained by tunable diode laser absorption spectroscopy. Line assignments are made using a combination of empirically known energy levels and predictions from the new POKAZATEL variational line list. 2030 of the observed lines are assigned to 2937 transitions, once blends are taken into account. 126 new energy levels of H$_2$$^{16}$O are identified. The assigned transitions belong to 136 bands and span rotational states up to $J=27$.

physics.chem-ph↗

Optical Frequency Comb Fourier Transform Spectroscopy with Sub-Nominal Resolution - Principles and Implementation

Broadband precision spectroscopy is indispensable for providing high fidelity molecular parameters for spectroscopic databases. We have recently shown that mechanical Fourier transform spectrometers based on optical frequency combs can measure broadband high-resolution molecular spectra undistorted by the instrumental line shape (ILS) and with a highly precise frequency scale provided by the comb. The accurate measurement of the power of the comb modes interacting with the molecular sample was achieved by acquiring single-burst interferograms with nominal resolution precisely matched to the comb mode spacing. Here we give a full theoretical description of this sub-nominal resolution method and describe in detail the experimental and numerical steps needed to retrieve ILS-free molecular spectra, i.e. with ILS-induced distortion below the noise level. We investigate the accuracy of the transition line centers retrieved by fitting to the absorption lines measured using this method. We verify the performance by measuring an ILS-free cavity-enhanced low-pressure spectrum of the 3ν1+ν3 band of CO2. We observe and quantify collisional narrowing of absorption line shape, for the first time with a comb-based spectroscopic technique. Thus retrieval of line shape parameters with accuracy not limited by the Voigt profile is now possible for entire absorption bands acquired simultaneously.

physics.ins-det↗

Sensitive and broadband measurement of dispersion in a cavity using a Fourier transform spectrometer with kHz resolution

Optical cavities provide high sensitivity to dispersion since their resonance frequencies depend on the index of refraction. We present a direct, broadband, and accurate measurement of the modes of a high finesse cavity using an optical frequency comb and a mechanical Fourier transform spectrometer with a kHz-level resolution. We characterize 16000 cavity modes spanning 16 THz of bandwidth in terms of center frequency, linewidth, and amplitude. We retrieve the group delay dispersion of the cavity mirror coatings and pure N${_2}$ with 0.1 fs${^2}$ precision and 1 fs${^2}$ accuracy, as well as the refractivity of the 3ν1+ν3 absorption band of CO${_2}$ with 5 x 10${^{-12}}$ precision. This opens up for broadband refractive index metrology and calibration-free spectroscopy of entire molecular bands.

physics.ins-det↗

Mid-infrared continuous-filtering Vernier spectroscopy using a doubly resonant optical parametric oscillator

We present a continuous-filtering Vernier spectrometer operating in the 3.15-3.4 $μ$m range, based on a femtosecond doubly resonant optical parametric oscillator, a cavity with a finesse of 340, a grating mounted on a galvo scanner and two photodiodes. The spectrometer allows acquisition of one spectrum spanning 250 nm of bandwidth in 25 ms with 8 GHz resolution, sufficient for resolving molecular lines at atmospheric pressure. An active lock ensures good frequency and intensity stability of the consecutive spectra and enables continuous signal acquisition and efficient averaging. The relative frequency scale is calibrated using a Fabry-Perot etalon or, alternatively, the galvo scanner position signal. We measure spectra of pure CH${_4}$ as well as dry and laboratory air and extract CH${_4}$ and H${_2}$O concentrations by multiline fitting of model spectra. The figure of merit of the spectrometer is 1.7x10${^-}$${^9}$ cm${^-}$${^1}$ Hz${^-}$${^1}$${^/}$${^2}$ per spectral element and the minimum detectable concentration of CH${_4}$ is 360 ppt Hz${^-}$${^1}$${^/}$${^2}$, averaging down to 90 ppt after 16 s.

physics.ins-det↗

Signal line shapes of Fourier transform cavity-enhanced frequency modulation spectroscopy with optical frequency combs

We present a thorough analysis of the signal line shapes of Fourier transform-based noise-immune cavity-enhanced optical frequency comb spectroscopy (NICE-OFCS). We discuss the signal dependence on the ratio of the modulation frequency, f${_m}$, to the molecular line width, Γ. We compare a full model of the signals and a simplified absorption-like analytical model that has high accuracy for low f${_m}$/Γ ratios and is much faster to compute. We verify the theory experimentally by measuring and fitting NICE-OFCS spectra of CO${_2}$ at 1575 nm using a system based on an Er:fiber femtosecond laser and a cavity with a finesse of ~11000.

physics.optics↗

Optical frequency comb spectroscopy at 3-5.4 μm with a doubly resonant optical parametric oscillator

We present a versatile mid-infrared frequency comb spectroscopy system based on a doubly resonant optical parametric oscillator tunable in the 3-5.4 μm range and two detection methods, a Fourier transform spectrometer (FTS) and a Vernier spectrometer. Using the FTS with a multipass cell we measure high-precision broadband absorption spectra of CH$_4$ and NO at ~3.3 μm and ~5.2 μm, respectively, and of atmospheric species (CH$_4$, CO, CO$_2$ and H$_2$O) in air in the signal and idler wavelength range. The figure of merit of the system is on the order of 10$^{-8}$ cm$^{-1}$ Hz$^{-1/2}$ per spectral element, and multiline fitting yields minimum detectable concentrations of 10-20 ppb Hz$^{-1/2}$ for CH$_4$, NO and CO. For the first time in the mid-infrared, we perform continuous-filtering Vernier spectroscopy using a low finesse enhancement cavity, a grating and a single detector, and measure the absorption spectrum of CH$_4$ and H$_2$O in ambient air at ~3.3 μm.

physics.optics↗

Surpassing the Path-Limited Resolution of a Fourier Transform Spectrometer with Frequency Combs

Fourier transform spectroscopy based on incoherent light sources is a well-established tool in research fields from molecular spectroscopy and atmospheric monitoring to material science and biophysics. It provides broadband molecular spectra and information about the molecular structure and composition of absorptive media. However, the spectral resolution is fundamentally limited by the maximum delay range (Δ$_{max}$) of the interferometer, so acquisition of high-resolution spectra implies long measurement times and large instrument size. We overcome this limit by combining the Fourier transform spectrometer with an optical frequency comb and measuring the intensities of individual comb lines by precisely matching the Δ$_{max}$ to the comb line spacing. This allows measurements of absorption lines narrower than the nominal (optical path-limited) resolution without ringing effects from the instrumental lineshape and reduces the acquisition time and interferometer length by orders of magnitude.

physics.optics↗

Noise-immune cavity-enhanced optical frequency comb spectroscopy: A sensitive technique for high-resolution broadband molecular detection

Noise-immune cavity-enhanced optical frequency comb spectroscopy (NICE-OFCS) is a recently developed technique that utilizes phase modulation to obtain immunity to frequency-to-amplitude noise conversion by the cavity modes and yields high absorption sensitivity over a broad spectral range. We describe the principles of the technique and discuss possible comb-cavity matching solutions. We present a theoretical description of NICE-OFCS signals detected with a Fourier transform spectrometer (FTS), and validate the model by comparing it to experimental CO2 spectra around 1575 nm. Our system is based on an Er:fiber femtosecond laser locked to a cavity and phase-modulated at a frequency equal to a multiple of the cavity free spectral range (FSR). The NICE-OFCS signal is detected by a fast-scanning FTS equipped with a high-bandwidth commercial detector. We demonstrate a simple method of passive locking of the modulation frequency to the cavity FSR that significantly improves the long term stability of the system, allowing averaging times on the order of minutes. Using a cavity with a finesse of ~9000 we obtain absorption sensitivity of 6.4 x 10^{-11} cm^{-1} Hz^{-1/2} per spectral element, and concentration detection limit for CO2 of 450 ppb Hz^{-1/2}, determined by multiline fitting.

physics.optics↗