SearcharxivSearch

arXiv subjects

Amirul Hasan

Publications and source records attributed to Amirul Hasan.

7 recordsLinked to original sources

Pre-shipment optical characterization of the SCALES instrument

The Slicer Combined with an Array of Lenslets for Exoplanet Spectroscopy (SCALES) instrument is a 1-5 micron imager and 2-5 micron integral field spectrograph, currently being commissioned on the Keck II Telescope. SCALES is optimized for exoplanet high-contrast imaging and spectroscopic characterization, and will be sensitive to older, colder exoplanets than existing instrumentation. The 12.3" x 12.3" imaging channel is designed to replicate the capabilities of NIRC2, and the low (R~35-200, 2.2" x 2.2" FOV) and medium (R~2500-5000, 0.36" x 0.34" FOV) spectral resolution modes offer new capabilities compared to existing Keck instrumentation. We present preliminary optical performance results from laboratory testing and commissioning of SCALES.

astro-ph.IM

A new broadband atmospheric dispersion corrector for HROS-TMT

Atmospheric dispersion causes light from celestial objects with different wavelengths to refract at varying angles as it passes through Earth's atmosphere. This effect results in an elongated image at the focal plane of a telescope and diminishes fiber coupling efficiency into spectrographs. We propose an optical design that incorporates a Rotational Atmospheric Dispersion Corrector (RADC) to address the broadband dispersion encountered in the multi-object mode of the High-Resolution Optical Spectrograph (HROS) on the Thirty Meter Telescope (TMT). The RADC corrects the dispersion across the entire wavelength range (0.31-1 micron), using Amici prisms optimized for over 90% transmission efficiency and minimal angular deviation of the beam from the optical axis after dispersion correction. For enhanced accuracy, particularly in the blue region, we have, for the first time, implemented the Filippenko (1982) model in Zemax via a custom Dynamic-Link Library (DLL) file.

astro-ph.IM

A multi-functional fiber positioning system for Extremely Large Telescopes

We present a conceptual design for a fiber positioning system for multi-object high-resolution spectroscopy, designed to be compatible with the upcoming large telescopes with a wide field of view. The design incorporates multiple Atmospheric Dispersion Correctors (ADCs) and tip-tilt mirrors that receive non-telecentric input from individual targets and direct it to the ADCs. Here, we introduce a mechanical design for the fiber positioner that accommodates the optics and operates in a curved focal plane with a Radius of Curvature (R) of 3m. This mechanical design provides four degrees of freedom to access the focal volume, enhancing targeting efficiency. The proposed design and an efficient target allocation algorithm ensure a targeting efficiency of approximately 80-100% for a primary observation session. We also present a methodology for target assignment, positioning, and quantification based on sequential and Monte Carlo (MC) algorithms. This method has been tested on realistic fields with varying target densities to validate its performance.

astro-ph.IM

Atmospheric dispersion corrector for a multi-object spectroscopic mode of HROS-TMT

Highly multiplexed spectroscopic surveys have changed the astronomy landscape in recent years. However, these surveys are limited to low and medium spectral resolution. High spectral resolution spectroscopy is often photon starved and will benefit from a large telescope aperture. Multiplexed high-resolution surveys require a wide field of view and a large aperture for a suitable large number of bright targets. This requirement introduces several practical difficulties, especially for large telescopes, such as the future ELTs. Some of the challenges are the need for a wide field atmospheric dispersion corrector and to deal with the curved non-telecentric focal plane. Here, we present a concept of Multi-Object Spectroscopy (MOS) mode for TMT High-Resolution Optical Spectrograph (HROS), we have designed an atmospheric dispersion corrector for individual objects that fit inside a fiber positioner. We present the ZEMAX design and the performance of the atmospheric dispersion corrector for all elevations accessible by TMT.

astro-ph.IM

SCALES for Keck: Optical Design

SCALES is a high-contrast, infrared coronagraphic imager and integral field spectrograph (IFS) to be deployed behind the W.M. Keck Observatory adaptive optics system. A reflective optical design allows diffraction-limited imaging over a large wavelength range (1.0 - 5.0 microns). A microlens array-based IFS coupled with a lenslet reformatter ("slenslit") allow spectroscopy at both low (R = 35 - 250) and moderate (R = 2000 - 6500) spectral resolutions. The large wavelength range, diffraction-limited performance, high contrast coronagraphy and cryogenic operation present a unique optical design challenge. We present the full SCALES optical design, including performance modeling and analysis and manufacturing.

astro-ph.IM

Design of SCALES: A 2-5 Micron Coronagraphic Integral Field Spectrograph for Keck Observatory

We present the design of SCALES (Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy) a new 2-5 micron coronagraphic integral field spectrograph under construction for Keck Observatory. SCALES enables low-resolution (R~50) spectroscopy, as well as medium-resolution (R~4,000) spectroscopy with the goal of discovering and characterizing cold exoplanets that are brightest in the thermal infrared. Additionally, SCALES has a 12x12" field-of-view imager that will be used for general adaptive optics science at Keck. We present SCALES's specifications, its science case, its overall design, and simulations of its expected performance. Additionally, we present progress on procuring, fabricating and testing long lead-time components.

astro-ph.IM

Design of an IR Imaging Channel for the Keck Observatory SCALES Instrument

A next-generation instrument named, Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy (SCALES), is being planned for the W. M. Keck Observatory. SCALES will have an integral field spectrograph (IFS) and a diffraction-limited imaging channel to discover and spectrally characterize the directly imaged exoplanets. Operating at thermal infrared wavelengths (1-5 micron, and a goal of 0.6-5 micron), the imaging channel of the SCALES is designed to cover a 12"x 12" field of view with low distortions and high throughput. Apart from expanding the mid-infrared science cases and providing a potential upgrade/alternative for the NIRC2, the H2RG detector of the imaging channel can take high-resolution images of the pupil to aid the alignment process.Further, the imaging camera would also assist in small field acquisition for the IFS arm. In this work, we present the optomechanical design of the imager and evaluate its capabilities and performances.

astro-ph.IM