Searcharxiv⌕ Search

arXiv subjects

Amit Manicka

Publications and source records attributed to Amit Manicka.

2 recordsLinked to original sources

Simulating Vein Compressibility for Ultrasound-Guided Femoral Access: Speed, Accuracy, and Phantom Validation

In ultrasound-guided femoral access, probe pressure deforms the tissue and changes the vascular anatomy a robot observes. A simulator must reproduce these mechanics fast enough for robotic interaction, yet the computational effort needed for a clinically meaningful signal like vein collapse before artery is unclear. We test the feasibility of a physics-based simulation in NVIDIA's Isaac Sim for Healthcare, with Stable Neo-Hookean tissue solved by Vertex Block Descent on one GPU. A simulation of a low-fidelity cylindrical benchtop phantom with known geometry and mechanical properties, pressed by a robot, predicted its artery within 5 percentage points at every depth. It matched the vein within 3 points through 11 mm of a 25.4 mm press and followed the collapse behavior of the low-fidelity physical phantom. Across element size, time step, and solver iterations, wall clock time per frame scaled linearly with solver work, but accuracy did not improve with more work. The chosen setting reduced solver time per frame by a factor of 976, from 29,700 ms to 30.4 ms, while remaining within 1.03 points of the finest reference setting. The physics solver alone took 30.4 ms per frame, while the full stack, including ultrasound and graphics rendering, took 56.4 ms per frame. Finally, when seeded with realistic literature-based mechanical properties, the digital leg model compressed the vein far more than the artery at every setting, reproducing the expected clinical signal of vein collapse before artery, which is used to distinguish them. In total, these results suggest that the NVIDIA Isaac Sim platform may be suitable for augmenting reinforcement learning training or online simulation for autonomous femoral access with ultrasound.

cs.RO↗

Image detection-based high-throughput sorting of particles using traveling surface acoustic waves in microscale flows

Large particle sorters have potential applications in sorting microplastics and large biomaterials (>50 micrometer), such as tissues, spheroids, organoids, and embryos. Though great advancements have been made in image-based sorting of cells and particles (<50 micrometer), their translation for high-throughput sorting of larger biomaterials and particles (>50 micrometer) has been more limited. An image-based detection technique is highly desirable due to richness of the data (including size, shape, color, morphology, and optical density) that can be extracted from live images of individualized biomaterials or particles. Such a detection technique is label-free and can be integrated with a contact-free actuation mechanism such as one based on traveling surface acoustic waves (TSAWs). Recent advances in using TSAWs for sorting cells and particles (<50 micrometer) have demonstrated short response times (<1 ms), high biocompatibility, and reduced energy requirements to actuate. Additionally, TSAW-based devices are miniaturized and easier to integrate with an image-based detection technique. In this work, a high-throughput image-detection based large particle microfluidic sorting technique is implemented. The technique is used to separate binary mixtures of small and large polyethylene particles (ranging between ~45-180 micrometer in size). All particles in flow were first optically interrogated for size, followed by actuations using momentum transfer from TSAW pulses, if they satisfied the size cutoff criterion. The effect of control parameters such as duration and power of TSAW actuation pulse, inlet flow rates, and sample dilution on sorting efficiency and throughput was observed. At the chosen conditions, this sorting technique can sort on average ~4.9-34.3 particles/s (perform ~2-3 actuations/s), depending on the initial sample composition and concentration.

physics.app-ph↗