A Helical-Deflector-Based Radio-Frequency Spiral Scanning System for keV Energy Electrons

We present the design, modeling, and experimental validation of a radio-frequency based time-to-position conversion system for keV electrons incorporating a helical deflector operating in the 400-1000 MHz range. The device performs circular deflection of the electrons when driven by a single RF frequency and enables spiral scanning when two phase-locked RF voltages with slightly different frequencies are applied. The superposition of the two phase-locked RF voltages produces an amplitude-beating field whose slowly varying envelope modulates the deflection radius, transforming the circular scan into a controlled spiral on the detector plane. A detailed theoretical model describing the electron dynamics under two phase-locked RF voltages with different frequencies was derived, yielding analytical expressions for the transverse velocity and radius-vector components at the deflector exit. The experimental studies demonstrated good agreement with the model predictions. Spiral scanning will allow measurements with picosecond resolution in a temporal dynamic range 1-2 orders of magnitude larger than the period of the circular scanning.

physics.ins-det

Compact sub-10 ps Resolution Radio Frequency Photomultiplier Tube

Experimental measurements of the radial spreading of photoelectrons emitted from a multi-alkali photocathode in a MCP-based photomultiplier tube have shown that, for photon wavelengths of 455 nm, 515 nm and 625 nm, the maximum initial energies of the emitted photoelectrons are approximately 0.3 eV, 0.2 eV and 0.1 eV respectively. Combining these experimental results with simulations performed using the SIMION simulation package, a compact radio-frequency photoelectron multiplier tube with a temporal resolution better than 10 ps is proposed. The device would be suitable for applications in several fields, particularly in medical optical instruments employing time-correlated single-photon counting.

physics.ins-det

Picosecond Precision Heavy-Ion Detector for Λ Hypernuclei Lifetime Studies

In this paper, we present the design and preliminary performance evaluation of a new heavy-ion detector for direct measurements of heavy Λ hypernuclei lifetime. The detector employs the previously developed 10 picosecond resolution Radio Frequency (RF) Timer, which converts the temporal information of incident particles into spatial coordinates of secondary or photoelectrons on a position-sensitive detector by means of circular RF scanning in the 500-1000 MHz range. Here, we report the detector design to achieve efficient suppression of accidental background and effective separation of prompt reaction products and delayed events from Λ hypernuclei decays, results of test studies carried out with RF synchronized laser as well as preliminary results obtained by using alpha particles. Dedicated Monte-Carlo simulations have been performed to estimate the detector's performance under realistic experimental conditions at RF-driven electron, photon, or proton beams. The results confirm the feasibility of the proposed design and provide a basis for upcoming experimental measurements, based on the delayed fission detection.

physics.ins-det

Advanced Radio Frequency Timing AppaRATus (ARARAT) Technique and Applications

The development of the advanced Radio Frequency Timer of electrons is described. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, based on similar principles, routinely operate in the ps and sub-ps time domain, but have substantial slow readout system. Here, we report a device, where the position sensor, consisting of microchannel plates and a delay-line anode, produces ~ns duration pulses which can be processed by using regular fast electronics. A photon sensor based on this technique, the Radio Frequency Photo-Multiplier Tube (RFPMT), has demonstrated a timing resolution of ~10 ps and a time stability of ~0.5 ps, FWHM. This makes the apparatus highly suited for Time Correlated Single Photon Counting which is widely used in optical microscopy and tomography of biological samples. The first application in lifetime measurements of quantum states of graphene, under construction at the A. I. Alikhanyan National Science Laboratory (AANL), is outlined. This is followed by a description of potential RFPMT applications in time-correlated Diffuse Optical Tomography, time-correlated Stimulated Emission Depletion microscopy, hybrid FRET/STED nanoscopy and Time-of-Flight Positron Emission Tomography.

physics.ins-det

An RF Timer of Electrons and Photons with the Potential to reach Picosecond Precision

This paper describes a new radio frequency timer of keV energy electrons. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, based on similar principles, routinely operate in the ps and sub-ps time domain, but have substantial dead time associated with the readout system. Here, we report a new type of RF timing technique, where the position sensor, consisting of microchannel plates and a delay-line anode, produces ~ns duration pulses with small dead time. Measurements made with sub-ps duration laser pulses, synchronized to the radio frequency power, produced a timing resolution of ~10 ps. This ultra-high precision technique has potential applications in a large variety of scientific devices, and in all cases, electrons are timed and detected simultaneously in the same device.

physics.ins-det

Compton Edge probing basic physics at Jefferson Laboratory: light speed isotropy and Lorentz invariance

We propose to study of the light speed isotropy and Lorentz invariance at Jefferson Laboratory by means of the measurements of the Compton Edge using of the Hall A/C existing experimental setup. Methodologically the same experiment has already been successfully elaborated at GRAAL experiment at the European Synchrotron Radiation Facility in Grenoble with 6 GeV electron beam. This Proposal states two goals expected to be reached at Jefferson Laboratory, both on Lorentz invariance: (a) the one-way light speed isotropy testing accuracy, following from conservative evaluations at numerical simulations, to about an order of magnitude better than was GRAAL's; (b) the dependence of the light speed on the velocity of the apparatus (Kennedy-Thorndike measurement) will be traced to an accuracy about 3 orders of magnitudes better than the available limits.

physics.acc-ph

Alpha-spectroscopy of Cf-252 decays: A new approach to searching for the octoneutron

Recently an experimental evidence of emission of neutron clusters consisting of eight neutrons - octoneutrons was reported. The experiment was based on the search for daughter nuclei associated with the octoneutron radioactivity of the Cf-252 nucleus. The effect of long-time build-up of daughter nuclei with a long half-life and gamma spectroscopy was utilized. In this paper we consider the alpha spectroscopy as an alternative method of searching for octoneutron in Cf-252 decays.

nucl-ex

A Radio Frequency Helical Deflector for keV Electrons

This paper describes a helical deflector to perform circular sweeps of keV electrons by means of radio frequency fields in a frequency range 500-1000 MHz. By converting the time dependence of incident electrons to a hit position dependence on a circle, this device can potentially achieve extremely precise timing. The system can be adjusted to the velocity of the electrons to exclude the reduction of deflection sensitivity due to finite transit time effects. The deflection electrodes form a resonant circuit, with quality factor Q in excess of 100, and at resonance the sensitivity of the deflection system is around 1~mm per V of applied RF input.

physics.acc-ph

Radio Frequency Phototube, Optical Clock and Precise Measurements in Nuclear Physics

Recently a new experimental program of novel systematic studies of light hypernuclei using pionic decay was established at JLab (Study of Light Hypernuclei by Pionic Decay at JLab, JLab Experiment PR-08-012). The highlights of the proposed program include high precision measurements of binding energies of hypernuclei by using a high resolution pion spectrometer, HpiS. The average values of binding energies will be determined within an accuracy of ~10 keV or better. Therefore, the crucial point of this program is an absolute calibration of the HpiS with accuracy 10E-4 or better. The merging of continuous wave laser-based precision optical-frequency metrology with mode-locked ultrafast lasers has led to precision control of the visible frequency spectrum produced by mode-locked lasers. Such a phase-controlled mode-locked laser forms the foundation of an optical clock or femtosecond optical frequency comb (OFC) generator, with a regular comb of sharp lines with well defined frequencies. Combination of this technique with a recently developed radio frequency (RF) phototube results in a new tool for precision time measurement. We are proposing a new time-of-flight (TOF) system based on an RF phototube and OFC technique. The proposed TOF system achieves 10 fs instability level and opens new possibilities for precise measurements in nuclear physics such as an absolute calibration of magnetic spectrometers within accuracy 10E-4 - 10E-5.

nucl-ex