Searcharxiv⌕ Search

arXiv subjects

Anders Eklund

Publications and source records attributed to Anders Eklund.

At least 37 records · Page 2Linked to original sources

Anatomically informed Bayesian spatial priors for fMRI analysis

Existing Bayesian spatial priors for functional magnetic resonance imaging (fMRI) data correspond to stationary isotropic smoothing filters that may oversmooth at anatomical boundaries. We propose two anatomically informed Bayesian spatial models for fMRI data with local smoothing in each voxel based on a tensor field estimated from a T1-weighted anatomical image. We show that our anatomically informed Bayesian spatial models results in posterior probability maps that follow the anatomical structure.

stat.ME↗

Micromagnetic Modeling of Telegraphic Mode Jumping in Microwave Spin Torque Oscillators

The time domain stability of microwave spin torque oscillators (STOs) has been investigated by systematic micromagnetic simulations. A model based on internal spin wave reflection at grain boundaries with reduced exchange coupling was implemented and used to study the oscillator under quasi-stable operating conditions. Telegraphic mode jumping between two operating frequencies (23.3 and 24.1 GHz) was observed in the time domain with characteristic dwell times in the range of 10-100 ns. The oscillating volume was shown to have a different shape at the distinct operating frequencies. The shape difference is governed by spin wave reflections at the grain boundaries. The resulting non-linear behavior of the oscillator was shown to be a collective effect of spin wave scattering at different locations within a few spin wavelengths from the nano-contact.

cond-mat.mes-hall↗

Generating Diffusion MRI scalar maps from T1 weighted images using generative adversarial networks

Diffusion magnetic resonance imaging (diffusion MRI) is a non-invasive microstructure assessment technique. Scalar measures, such as FA (fractional anisotropy) and MD (mean diffusivity), quantifying micro-structural tissue properties can be obtained using diffusion models and data processing pipelines. However, it is costly and time consuming to collect high quality diffusion data. Here, we therefore demonstrate how Generative Adversarial Networks (GANs) can be used to generate synthetic diffusion scalar measures from structural T1-weighted images in a single optimized step. Specifically, we train the popular CycleGAN model to learn to map a T1 image to FA or MD, and vice versa. As an application, we show that synthetic FA images can be used as a target for non-linear registration, to correct for geometric distortions common in diffusion MRI.

cs.CV↗

Graph Spectral Characterization of Brain Cortical Morphology

The human brain cortical layer has a convoluted morphology that is unique to each individual. Characterization of the cortical morphology is necessary in longitudinal studies of structural brain change, as well as in discriminating individuals in health and disease. A method for encoding the cortical morphology in the form of a graph is presented. The design of graphs that encode the global cerebral hemisphere cortices as well as localized cortical regions is proposed. Spectral metrics derived from these graphs are then studied and proposed as descriptors of cortical morphology. As proof-of-concept of their applicability in characterizing cortical morphology, the metrics are studied in the context of hemispheric asymmetry as well as gender dependent discrimination of cortical morphology.

q-bio.NC↗

Refacing: reconstructing anonymized facial features using GANs

Anonymization of medical images is necessary for protecting the identity of the test subjects, and is therefore an essential step in data sharing. However, recent developments in deep learning may raise the bar on the amount of distortion that needs to be applied to guarantee anonymity. To test such possibilities, we have applied the novel CycleGAN unsupervised image-to-image translation framework on sagittal slices of T1 MR images, in order to reconstruct facial features from anonymized data. We applied the CycleGAN framework on both face-blurred and face-removed images. Our results show that face blurring may not provide adequate protection against malicious attempts at identifying the subjects, while face removal provides more robust anonymization, but is still partially reversible.

cs.CV↗

Characterization of Brain Cortical Morphology Using Localized Topology-Encoding Graphs

The human brain cortical layer has a convoluted morphology that is unique to each individual. Characterization of the cortical morphology is necessary in longitudinal studies of structural brain change, as well as in discriminating individuals in health and disease. A method for encoding the cortical morphology in the form of a graph is presented. The design of graphs that encode the global cerebral hemisphere cortices as well as localized cortical regions is proposed. Spectral features of these graphs are then studied and proposed as descriptors of cortical morphology. As proof-of-concept of their applicability in characterizing cortical morphology, the descriptors are studied in the context of discriminating individuals based on their sex.

cs.CV↗

Reply to Chen et al.: Parametric methods for cluster inference perform worse for two-sided t-tests

One-sided t-tests are commonly used in the neuroimaging field, but two-sided tests should be the default unless a researcher has a strong reason for using a one-sided test. Here we extend our previous work on cluster false positive rates, which used one-sided tests, to two-sided tests. Briefly, we found that parametric methods perform worse for two-sided t-tests, and that non-parametric methods perform equally well for one-sided and two-sided tests.

stat.AP↗

Generative Adversarial Networks for Image-to-Image Translation on Multi-Contrast MR Images - A Comparison of CycleGAN and UNIT

In medical imaging, a general problem is that it is costly and time consuming to collect high quality data from healthy and diseased subjects. Generative adversarial networks (GANs) is a deep learning method that has been developed for synthesizing data. GANs can thereby be used to generate more realistic training data, to improve classification performance of machine learning algorithms. Another application of GANs is image-to-image translations, e.g. generating magnetic resonance (MR) images from computed tomography (CT) images, which can be used to obtain multimodal datasets from a single modality. Here, we evaluate two unsupervised GAN models (CycleGAN and UNIT) for image-to-image translation of T1- and T2-weighted MR images, by comparing generated synthetic MR images to ground truth images. We also evaluate two supervised models; a modification of CycleGAN and a pure generator model. A small perceptual study was also performed to evaluate how visually realistic the synthesized images are. It is shown that the implemented GAN models can synthesize visually realistic MR images (incorrectly labeled as real by a human). It is also shown that models producing more visually realistic synthetic images not necessarily have better quantitative error measurements, when compared to ground truth data. Code is available at https://github.com/simontomaskarlsson/GAN-MRI

cs.CV↗

Cluster Failure Revisited: Impact of First Level Design and Data Quality on Cluster False Positive Rates

Methodological research rarely generates a broad interest, yet our work on the validity of cluster inference methods for functional magnetic resonance imaging (fMRI) created intense discussion on both the minutia of our approach and its implications for the discipline. In the present work, we take on various critiques of our work and further explore the limitations of our original work. We address issues about the particular event-related designs we used, considering multiple event types and randomisation of events between subjects. We consider the lack of validity found with one-sample permutation (sign flipping) tests, investigating a number of approaches to improve the false positive control of this widely used procedure. We found that the combination of a two-sided test and cleaning the data using ICA FIX resulted in nominal false positive rates for all datasets, meaning that data cleaning is not only important for resting state fMRI, but also for task fMRI. Finally, we discuss the implications of our work on the fMRI literature as a whole, estimating that at least 10% of the fMRI studies have used the most problematic cluster inference method (P = 0.01 cluster defining threshold), and how individual studies can be interpreted in light of our findings. These additional results underscore our original conclusions, on the importance of data sharing and thorough evaluation of statistical methods on realistic null data.

stat.AP↗

Bayesian uncertainty quantification in linear models for diffusion MRI

Diffusion MRI (dMRI) is a valuable tool in the assessment of tissue microstructure. By fitting a model to the dMRI signal it is possible to derive various quantitative features. Several of the most popular dMRI signal models are expansions in an appropriately chosen basis, where the coefficients are determined using some variation of least-squares. However, such approaches lack any notion of uncertainty, which could be valuable in e.g. group analyses. In this work, we use a probabilistic interpretation of linear least-squares methods to recast popular dMRI models as Bayesian ones. This makes it possible to quantify the uncertainty of any derived quantity. In particular, for quantities that are affine functions of the coefficients, the posterior distribution can be expressed in closed-form. We simulated measurements from single- and double-tensor models where the correct values of several quantities are known, to validate that the theoretically derived quantiles agree with those observed empirically. We included results from residual bootstrap for comparison and found good agreement. The validation employed several different models: Diffusion Tensor Imaging (DTI), Mean Apparent Propagator MRI (MAP-MRI) and Constrained Spherical Deconvolution (CSD). We also used in vivo data to visualize maps of quantitative features and corresponding uncertainties, and to show how our approach can be used in a group analysis to downweight subjects with high uncertainty. In summary, we convert successful linear models for dMRI signal estimation to probabilistic models, capable of accurate uncertainty quantification.

stat.AP↗

Reply to Cox et al. and Kessler et al.: Data and code sharing is the way forward for fMRI

We are glad that our paper has generated intense discussions in the fMRI field, on how to analyze fMRI data and how to correct for multiple comparisons. The goal of the paper was not to disparage any specific fMRI software, but to point out that parametric statistical methods are based on a number of assumptions that are not always valid for fMRI data, and that non-parametric statistical methods are a good alternative. Through AFNIs introduction of non-parametric statistics in the function 3dttest++, the three most common fMRI softwares now all support non-parametric group inference (SPM through the toolbox SnPM, and FSL through the function randomise).

stat.AP↗

A Bayesian Heteroscedastic GLM with Application to fMRI Data with Motion Spikes

We propose a voxel-wise general linear model with autoregressive noise and heteroscedastic noise innovations (GLMH) for analyzing functional magnetic resonance imaging (fMRI) data. The model is analyzed from a Bayesian perspective and has the benefit of automatically down-weighting time points close to motion spikes in a data-driven manner. We develop a highly efficient Markov Chain Monte Carlo (MCMC) algorithm that allows for Bayesian variable selection among the regressors to model both the mean (i.e., the design matrix) and variance. This makes it possible to include a broad range of explanatory variables in both the mean and variance (e.g., time trends, activation stimuli, head motion parameters and their temporal derivatives), and to compute the posterior probability of inclusion from the MCMC output. Variable selection is also applied to the lags in the autoregressive noise process, making it possible to infer the lag order from the data simultaneously with all other model parameters. We use both simulated data and real fMRI data from OpenfMRI to illustrate the importance of proper modeling of heteroscedasticity in fMRI data analysis. Our results show that the GLMH tends to detect more brain activity, compared to its homoscedastic counterpart, by allowing the variance to change over time depending on the degree of head motion.

stat.AP↗

A defense of using resting state fMRI as null data for estimating false positive rates

A recent Editorial by Slotnick (2017) reconsiders the findings of our paper on the accuracy of false positive rate control with cluster inference in fMRI (Eklund et al, 2016), in particular criticising our use of resting state fMRI data as a source for null data in the evaluation of task fMRI methods. We defend this use of resting fMRI data, as while there is much structure in this data, we argue it is representative of task data noise and as such analysis software should be able to accommodate this noise. We also discuss a potential problem with Slotnick's own method.

stat.AP↗

Bayesian Non-Central Chi Regression For Neuroimaging

We propose a regression model for non-central $χ$ (NC-$χ$) distributed functional magnetic resonance imaging (fMRI) and diffusion weighted imaging (DWI) data, with the heteroscedastic Rician regression model as a prominent special case. The model allows both parameters in the NC-$χ$ distribution to be linked to explanatory variables, with the relevant covariates automatically chosen by Bayesian variable selection. A highly efficient Markov chain Monte Carlo (MCMC) algorithm is proposed for simulating from the joint Bayesian posterior distribution of all model parameters and the binary covariate selection indicators. Simulated fMRI data is used to demonstrate that the Rician model is able to localize brain activity much more accurately than the traditionally used Gaussian model at low signal-to-noise ratios. Using a diffusion dataset from the Human Connectome Project, it is also shown that the commonly used approximate Gaussian noise model underestimates the mean diffusivity (MD) and the fractional anisotropy (FA) in the single-diffusion tensor model compared to the theoretically correct Rician model.

stat.AP↗

Gaussian process regression can turn non-uniform and undersampled diffusion MRI data into diffusion spectrum imaging

We propose to use Gaussian process regression to accurately estimate the diffusion MRI signal at arbitrary locations in q-space. By estimating the signal on a grid, we can do synthetic diffusion spectrum imaging: reconstructing the ensemble averaged propagator (EAP) by an inverse Fourier transform. We also propose an alternative reconstruction method guaranteeing a nonnegative EAP that integrates to unity. The reconstruction is validated on data simulated from two Gaussians at various crossing angles. Moreover, we demonstrate on non-uniformly sampled in vivo data that the method is far superior to linear interpolation, and allows a drastic undersampling of the data with only a minor loss of accuracy. We envision the method as a potential replacement for standard diffusion spectrum imaging, in particular when acquistion time is limited.

stat.AP↗

Fast Bayesian whole-brain fMRI analysis with spatial 3D priors

Spatial whole-brain Bayesian modeling of task-related functional magnetic resonance imaging (fMRI) is a great computational challenge. Most of the currently proposed methods therefore do inference in subregions of the brain separately or do approximate inference without comparison to the true posterior distribution. A popular such method, which is now the standard method for Bayesian single subject analysis in the SPM software, is introduced in Penny et al. (2005b). The method processes the data slice-by-slice and uses an approximate variational Bayes (VB) estimation algorithm that enforces posterior independence between activity coefficients in different voxels. We introduce a fast and practical Markov chain Monte Carlo (MCMC) scheme for exact inference in the same model, both slice-wise and for the whole brain using a 3D prior on activity coefficients. The algorithm exploits sparsity and uses modern techniques for efficient sampling from high-dimensional Gaussian distributions, leading to speed-ups without which MCMC would not be a practical option. Using MCMC, we are for the first time able to evaluate the approximate VB posterior against the exact MCMC posterior, and show that VB can lead to spurious activation. In addition, we develop an improved VB method that drops the assumption of independent voxels a posteriori. This algorithm is shown to be much faster than both MCMC and the original VB for large datasets, with negligible error compared to the MCMC posterior.

stat.CO↗

Spin-Torque and Spin-Hall Nano-Oscillators

This paper reviews the state of the art in spin-torque and spin Hall effect driven nano-oscillators. After a brief introduction to the underlying physics, the authors discuss different implementations of these oscillators, their functional properties in terms of frequency range, output power, phase noise, and modulation rates, and their inherent propensity for mutual synchronization. Finally, the potential for these oscillators in a wide range of applications, from microwave signal sources and detectors to neuromorphic computation elements, is discussed together with the specific electronic circuitry that has so far been designed to harness this potential.

cond-mat.mes-hall↗

Can parametric statistical methods be trusted for fMRI based group studies?

The most widely used task fMRI analyses use parametric methods that depend on a variety of assumptions. While individual aspects of these fMRI models have been evaluated, they have not been evaluated in a comprehensive manner with empirical data. In this work, a total of 2 million random task fMRI group analyses have been performed using resting state fMRI data, to compute empirical familywise error rates for the software packages SPM, FSL and AFNI, as well as a standard non-parametric permutation method. While there is some variation, for a nominal familywise error rate of 5% the parametric statistical methods are shown to be conservative for voxel-wise inference and invalid for cluster-wise inference; in particular, cluster size inference with a cluster defining threshold of p = 0.01 generates familywise error rates up to 60%. We conduct a number of follow up analyses and investigations that suggest the cause of the invalid cluster inferences is spatial auto correlation functions that do not follow the assumed Gaussian shape. By comparison, the non-parametric permutation test, which is based on a small number of assumptions, is found to produce valid results for voxel as well as cluster wise inference. Using real task data, we compare the results between one parametric method and the permutation test, and find stark differences in the conclusions drawn between the two using cluster inference. These findings speak to the need of validating the statistical methods being used in the neuroimaging field.

stat.AP↗