Searcharxiv⌕ Search

arXiv subjects

Andi Tan

Publications and source records attributed to Andi Tan.

43 records · Page 3Linked to original sources

Krypton and radon background in the PandaX-I dark matter experiment

We discuss an in-situ evaluation of the $^{85}$Kr, $^{222}$Rn, and $^{220}$Rn background in PandaX-I, a 120-kg liquid xenon dark matter direct detection experiment. Combining with a simulation, their contributions to the low energy electron-recoil background in the dark matter search region are obtained.

astro-ph.IM↗

PandaX-III: Searching for Neutrinoless Double Beta Decay with High Pressure $^{136}$Xe Gas Time Projection Chambers

Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (Particle And Astrophysical Xenon Experiment III) will search for the NLDBD of $^{136}$Xe at the China Jin Ping underground Laboratory (CJPL). In the first phase of the experiment, a high pressure gas Time Projection Chamber (TPC) will contain 200 kg, 90% $^{136}$Xe enriched gas operated at 10 bar. Fine pitch micro-pattern gas detector (Microbulk Micromegas) will be used at both ends of the TPC for the charge readout with a cathode in the middle. Charge signals can be used to reconstruct tracks of NLDBD events and provide good energy and spatial resolution. The detector will be immersed in a large water tank to ensure $\sim$5 m of water shielding in all directions. The second phase, a ton-scale experiment, will consist of five TPCs in the same water tank, with improved energy resolution and better control over backgrounds.

physics.ins-det↗

Dark Matter Results from First 98.7-day Data of PandaX-II Experiment

We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit to the spin-independent interaction between the ordinary and WIMP dark matter is set for a range of dark matter mass between 3.5 and 1000 GeV/c$^2$. The best upper limit on the scattering cross section is found $2.5\times 10^{-46}$ cm$^2$ for the WIMP mass 40 GeV/c$^2$ at 90% confidence level.

hep-ex↗

Dark Matter Search Results from the Commissioning Run of PandaX-II

We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken, while its dominant $^{85}$Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90\% upper limit is set on the spin-independent elastic WIMP-nucleon cross section with a lowest excluded cross section of 2.97$\times$10$^{-45}$~cm$^2$ at a WIMP mass of 44.7~GeV/c$^2$.

hep-ex↗

Performance of Photosensors in the PandaX-I Experiment

We report the long term performance of the photosensors, 143 one-inch R8520-406 and 37 three-inch R11410-MOD photomultipliers from Hamamatsu, in the first phase of the PandaX dual-phase xenon dark matter experiment. This is the first time that a significant number of R11410 photomultiplier tubes were operated in liquid xenon for an extended period, providing important guidance to the future large xenon-based dark matter experiments.

physics.ins-det↗

Low-mass dark matter search results from full exposure of PandaX-I experiment

We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass of 54.0\,kg, no significant excess event were found above the expected background. A profile likelihood analysis confirms our earlier finding that the PandaX-I data disfavor all positive low-mass WIMP signals reported in the literature under standard assumptions. A stringent bound on the low mass WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon detectors can be competitive for low-mass WIMP searches.

hep-ex↗

First dark matter search results from the PandaX-I experiment

We report on the first dark-matter (DM) search results from PandaX-I, a low threshold dual-phase xenon experiment operating at the China Jinping Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of exposure, no DM particle candidate event was found. This result sets a stringent limit for low-mass DM particles and disfavors the interpretation of previously-reported positive experimental results. The minimum upper limit, $3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar DM-particle-nucleon scattering cross section is obtained at a DM-particle mass of 49\,GeV/c$^2$ at 90\% confidence level.

hep-ex↗