Searcharxiv⌕ Search

arXiv subjects

Andrea Argan

Publications and source records attributed to Andrea Argan.

23 records · Page 2Linked to original sources

The e-ASTROGAM mission (exploring the extreme Universe with gamma rays in the MeV-GeV range)

e-ASTROGAM (`enhanced ASTROGAM') is a breakthrough Observatory mission dedicated to the study of the non-thermal Universe in the photon energy range from 0.3 MeV to 3 GeV. The mission is based on an advanced space-proven detector technology, with unprecedented sensitivity, angular and energy resolution, combined with polarimetric capability. In the largely unexplored MeV-GeV domain, e-ASTROGAM will open a new window on the non-thermal Universe, making pioneering observations of the most powerful Galactic and extragalactic sources, elucidating the nature of their relativistic outflows and their effects on Galactic ecosystems. With a line sensitivity in the MeV energy range one to two orders of magnitude better than previous generation instruments, will determine the origin of key isotopes fundamental for the understanding of supernova explosion and the chemical evolution of our Galaxy. The mission will provide unique data of significant interest to a broad astronomical community, complementary to powerful observatories such as LIGO-Virgo-GEO600-KAGRA, SKA, ALMA, E-ELT, TMT, LSST, JWST, Athena, CTA, IceCube, KM3NeT, and the promise of eLISA. Keywords: High-energy gamma-ray astronomy, High-energy astrophysics, Nuclear Astrophysics, Compton and Pair creation telescope, Gamma-ray bursts, Active Galactic Nuclei, Jets, Outflows, Multiwavelength observations of the Universe, Counterparts of gravitational waves, Fermi, Dark Matter, Nucleosynthesis, Early Universe, Supernovae, Cosmic Rays, Cosmic antimatter.

astro-ph.HE↗

The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a scientific assessment of the observational capabilities in the hard X-ray band

ATHENA is a large X-ray observatory, planned to be launched by ESA in 2028 towards an L2 orbit. One of the two instruments of the payload is the X-IFU: a cryogenic spectrometer based on a large array of TES microcalorimeters, able to perform integral field spectrography in the 0.2-12 keV band (2.5 eV FWHM at 6 keV). The X-IFU sensitivity is highly degraded by the particle background expected in the L2 orbit, which is induced by primary protons of both galactic and solar origin, and mostly by secondary electrons. To reduce the particle background level and enable the mission science goals, the instrument incorporates a Cryogenic AntiCoincidence detector (CryoAC). It is a 4 pixel TES based detector, placed <1 mm below the main array. In this paper we report a scientific assessment of the CryoAC observational capabilities in the hard X-ray band (E>10 keV). The aim of the study has been to understand if the present detector design can be improved in order to enlarge the X-IFU scientific capability on an energy band wider than the TES array. This is beyond the CryoAC baseline, being this instrument aimed to operate as anticoincidence particle detector and not conceived to perform X-ray observations.

astro-ph.IM↗

GAMMA-LIGHT: High-Energy Astrophysics above 10 MeV

High-energy phenomena in the cosmos, and in particular processes leading to the emission of gamma- rays in the energy range 10 MeV - 100 GeV, play a very special role in the understanding of our Universe. This energy range is indeed associated with non-thermal phenomena and challenging particle acceleration processes. The technology involved in detecting gamma-rays is challenging and drives our ability to develop improved instruments for a large variety of applications. GAMMA-LIGHT is a Small Mission which aims at an unprecedented advance of our knowledge in many sectors of astrophysical and Earth studies research. The Mission will open a new observational window in the low-energy gamma-ray range 10-50 MeV, and is configured to make substantial advances compared with the previous and current gamma-ray experiments (AGILE and Fermi). The improvement is based on an exquisite angular resolution achieved by GAMMA-LIGHT using state-of-the-art Silicon technology with innovative data acquisition. GAMMA-LIGHT will address all astrophysics issues left open by the current generation of instruments. In particular, the breakthrough angular resolution in the energy range 100 MeV - 1 GeV is crucial to resolve patchy and complex features of diffuse sources in the Galaxy as well as increasing the point source sensitivity. This proposal addresses scientific topics of great interest to the community, with particular emphasis on multifrequency correlation studies involving radio, optical, IR, X-ray, soft gamma-ray and TeV emission. At the end of this decade several new observatories will be operational including LOFAR, SKA, ALMA, HAWK, CTA. GAMMA-LIGHT will "fill the vacuum" in the 10 MeV-10 GeV band, and will provide invaluable data for the understanding of cosmic and terrestrial high-energy sources.

astro-ph.IM↗

Calibration strategies for the LAD instrument on-board LOFT

The Scientific objectives of the LOFT mission, e.g., the study of the Neutron Star equation of state and of the Strong Gravity, require accurate energy, time and flux calibration for the 500k channels of the SDD detectors, as well as the knowledge of the detector dead-time and of the detector response with respect to the incident angle of the photons. We report here the evaluations made to asses the calibration issues for the LAD instrument. The strategies for both ground and on-board calibrations, including astrophysical observations, show that the goals are achievable within the current technologies.

astro-ph.IM↗

POLARIX: a pathfinder mission of X-ray polarimetry

Since the birth of X-ray astronomy, spectral, spatial and timing observation improved dramatically, procuring a wealth of information on the majority of the classes of the celestial sources. Polarimetry, instead, remained basically unprobed. X-ray polarimetry promises to provide additional information procuring two new observable quantities, the degree and the angle of polarization. POLARIX is a mission dedicated to X-ray polarimetry. It exploits the polarimetric response of a Gas Pixel Detector, combined with position sensitivity, that, at the focus of a telescope, results in a huge increase of sensitivity. Three Gas Pixel Detectors are coupled with three X-ray optics which are the heritage of JET-X mission. POLARIX will measure time resolved X-ray polarization with an angular resolution of about 20 arcsec in a field of view of 15 arcmin $\times$ 15 arcmin and with an energy resolution of 20 % at 6 keV. The Minimum Detectable Polarization is 12 % for a source having a flux of 1 mCrab and 10^5 s of observing time. The satellite will be placed in an equatorial orbit of 505 km of altitude by a Vega launcher.The telemetry down-link station will be Malindi. The pointing of POLARIX satellite will be gyroless and it will perform a double pointing during the earth occultation of one source, so maximizing the scientific return. POLARIX data are for 75 % open to the community while 25 % + SVP (Science Verification Phase, 1 month of operation) is dedicated to a core program activity open to the contribution of associated scientists. The planned duration of the mission is one year plus three months of commissioning and SVP, suitable to perform most of the basic science within the reach of this instrument.

astro-ph.IM↗