SearcharxivSearch

arXiv subjects

Andrea Catalano

Publications and source records attributed to Andrea Catalano.

14 recordsLinked to original sources

Status and future development of the COSMOCal Project for absolute CMB polarization calibration

Cosmic Microwave Background (CMB) polarization measurements are pushing instrumental sensitivities to levels where calibration systematics become a dominant limitation. The large dynamic range between cosmological and Galactic emission prevents future experiments from relying only on diffuse sky measurements or standard celestial calibrators. To address this challenge, the COSmological Microwave Observations Calibrator (COSMOCal) project proposes an artificial calibration source deployed as a guest payload on a geostationary satellite, scheduled for launch by the Eutelsat group by 2030. This source will provide stable, well-characterized polarized microwave signals accessible to multiple ground-based observatories. In this work, we present the status of the project, the updated development timeline, and the refined scientific and technical requirements, defined with the observatories that plan to use this calibration source. Furthermore, we investigate the interplay between instrumental systematics and component separation in the presence of complex models of interstellar dust emission. We discuss in this paper how this can impact the recovery of the primordial signal, and whether residual calibration errors can degrade the performance of foreground cleaning algorithms.

astro-ph.IM

High-precision polarization measurements with Lumped Element Kinetic Inductance Detectors

This work aims to demonstrate that two arrays of Lumped Element Kinetic Inductance Detectors (LEKIDs), when employed in filled array configuration and separated by an external linear polarizer oriented at 45 degrees, can achieve the precision required by next-generation cosmological experiments. The focus here is on validating their ability to meet stringent uncertainty requirements, in particular for polarization angle reconstruction. To achieve this, the uncertainties in the reconstruction of the polarization angle have been characterized in the laboratory using a dedicated closed-circuit 100 mK dilution cryostat. This is optically coupled to a Martin-Puplett interferometer and a custom-designed sky simulator equipped with both photometric and polarized sources, allowing one to reproduce realistic ground-based observation conditions. This experimental setup allows us to generate intensity and polarization maps with diffraction-limited resolution, allowing us to determine the polarization angles and their associated uncertainties. The results show performance in line with expectations for the next generation CMB experiments. The polarization angle was reconstructed with an uncertainty of 6.5 arcmin.

astro-ph.IM

The PolarKID project: polarization measurements with KIDs for the next generation of CMB telescopes

The goal of the PolarKID project is testing a new method for the measurement of polarized sources, in order to identify all the possible instrumental systematic effects that could impact the detection of CMB B-modes of polarization. It employs the KISS (KIDs Interferometer Spectrum Survey) instrument coupled to a sky simulator and to sources such as point-like black bodies (simulating planets), a dipole (extended source) and a polarizer. We use filled-arrays Lumped Element Kinetic Inductance Detectors (LEKIDs) since they have multiple advantages when observing both in a photometry and in a polarimetry configuration

astro-ph.IM

CONCERTO: Instrument model of Fourier transform spectroscopy, white-noise components

Modern astrophysics relies on intricate instrument setups to meet the demands of sensitivity, sky coverage, and multi-channel observations. An example is the CONCERTO project, employing advanced technology like kinetic inductance detectors and a Martin-Puplett interferometer. This instrument, installed at the APEX telescope atop the Chajnantor plateau, began commissioning observations in April 2021. Following a successful commissioning phase that concluded in June 2021, CONCERTO was offered to the scientific community for observations, with a final observing run in December 2022. CONCERTO boasts an 18.5 arcmin field of view and a spectral resolution down to 1.45 GHz in the 130-310 GHz electromagnetic band. We developed a comprehensive instrument model of CONCERTO inspired by Fourier transform spectrometry principles to optimize performance and address systematic errors. This model integrates instrument noises, subsystem characteristics, and celestial signals, leveraging both physical data and simulations. Our methodology involves delineating simulation components, executing on-sky simulations, and comparing results with real observations. The resulting instrument model is pivotal, enabling a precise error correction and enhancing the reliability of astrophysical insights obtained from observational data. In this work, we focus on the description of three white-noise noise components included in the instrument model that characterize the white-noise level: the photon, the generation-recombination, and the amplifier noises.

astro-ph.IM

The case for an all-sky millimetre survey at sub-arcminute resolution

There are several new projects to survey the sky with millimetre eyes, the biggest being Simons Observatory and CMB-S4, in the Southern Hemisphere. The NIKA2 collaboration has acquired sufficient knowledge to build a large focal plane KID camera for a 15~m antenna. This would allow covering the whole Northern Hemisphere in five years at subarcminute resolution and with milliJansky point-source sensitivity. We describe the main scientific drivers for such a project: the SZ sky, the high-redshift millimetre Universe and the interstellar medium in our Galaxy and the nearby galaxies. We also show briefly the main difficulties (scientific, organisational, technical and financial).

astro-ph.IM

CONCERTO: instrument and status

CONCERTO (CarbON CII line in post-rEionization and ReionizaTiOn) is a low-resolution Fourier transform spectrometer dedicated to the study of star-forming galaxies and clusters of galaxies in the transparent millimeter windows from the ground. It is characterized by a wide instantaneous 18.6 arcmin field of view, operates at 130-310 GHz, and was installed on the 12-meter Atacama Pathfinder Experiment (APEX) telescope at 5100 m above sea level. CONCERTO's double focal planes host two arrays of 2152 kinetic inductance detectors and represent a pioneering instrument to meet a state-of-the-art scientific challenge. This paper introduces the CONCERTO instrument and explains its status, shows the first CONCERTO spectral maps of Orion, and describes the perspectives of the project.

astro-ph.IM

CONCERTO : Digital processing for finding and tuning LEKIDs

We describe the on-line algorithms developed to probe Lumped Element Kinetic Inductance Detectors (LEKID) in this paper. LEKIDs are millimeter wavelength detectors for astronomy. LEKID arrays are currently operated in different instruments as: NIKA2 at the IRAM telescope in Spain, KISS at the Teide Observatory telescope in Tenerife, and CONCERTO at the APEX 12-meter telescope in Chile. LEKIDs are superconducting microwave resonators able to detect the incoming light at millimeter wavelengths and they are well adapted for frequency multiplexing (currently up to 360 pixels on a single microwave guide). Nevertheless, their use for astronomical observations requires specific readout and acquisition systems both to deal with the instrumental and multiplexing complexity, and to adapt to the observational requirements (e.g. fast sampling rate, background variations, on-line calibration, photometric accuracy, etc). This paper presents the different steps of treatment from identifying the resonance frequency of each LEKID to the continuous automatic control of drifting LEKID resonance frequencies induced by background variations.

astro-ph.IM

CONCERTO: a breakthrough in wide field-of-view spectroscopy at millimeter wavelengths

CarbON CII line in post-rEionization and ReionizaTiOn (CONCERTO) is a low-resolution spectrometer with an instantaneous field-of-view of 18.6 arcmin, operating in the 130-310 GHz transparent atmospheric window. It is installed on the 12-meter Atacama Pathfinder Experiment (APEX) telescope at 5100 m above sea level. The Fourier transform spectrometer (FTS) contains two focal planes hosting a total of 4304 kinetic inductance detectors. The FTS interferometric pattern is recorded on the fly while continuously scanning the sky. One of the goals of CONCERTO is to characterize the large-scale structure of the Universe by observing the integrated emission from unresolved galaxies. This methodology is an innovative technique and is called line intensity mapping. In this paper, we describe the CONCERTO instrument, the effect of the vibration of the FTS beamsplitter, and the status of the CONCERTO main survey.

astro-ph.IM

Optical Response of Lumped-Element Kinetic-Inductance Detector Arrays

We present an analysis of the optical response of lumped-element kinetic-inductance detector arrays, based on the NIKA2 1mm array. This array has a dual-polarization sensitive Hilbert inductor for directly absorbing incident photons. We present the optical response calculated from a transmission line model, simulated with HFSS and measured using a Fourier transform spectrometer. We have estimated the energy absorbed by individual component of a pixel, such as the inductor. The difference between the absorption efficiencies is expected to be 20% from the simulations. The Fourier-transform spectroscopy measurement, performed on the actual NIKA2 arrays, validates our simulations. We discuss several possible ways to increase the absorption efficiency. This analysis can be used for optimization of the focal plane layout and can be extended to other kinetic inductance detector array designs in millimeter, sub-millimeter and terahertz frequency bands.

astro-ph.IM

Increased multiplexing of superconducting microresonator arrays by post-characterization adaptation of the on-chip capacitors

We present an interdigitated capacitor trimming technique for fine-tuning the resonance frequency of superconducting microresonators and increasing the multiplexing factor. We first measure the optical response of the array with a beam mapping system to link all resonances to their physical resonators. Then a new set of resonance frequencies with uniform spacing and higher multiplexing factor is designed. We use simulations to deduce the lengths that we should trim from the capacitor fingers in order to shift the resonances to the desired frequencies. The sample is then modified using contact lithography and re-measured using the same setup. We demonstrate this technique on a 112-pixel aluminum lumped-element kinetic-inductance detector array. Before trimming, the resonance frequency deviation of this array is investigated. The variation of the inductor width plays the main role for the deviation. After trimming, the mean fractional frequency error for identified resonators is -6.4e-4, with a standard deviation of 1.8e-4. The final optical yield is increased from 70.5% to 96.7% with no observable crosstalk beyond -15 dB during mapping. This technique could be applied to other photon-sensitive superconducting microresonator arrays for increasing the yield and multiplexing factor.

astro-ph.IM

The NIKA2 large field-of-view millimeter continuum camera for the 30-m IRAM telescope

Millimeter-wave continuum astronomy is today an indispensable tool for both general Astrophysics studies and Cosmology. General purpose, large field-of-view instruments are needed to map the sky at intermediate angular scales not accessible by the high-resolution interferometers and by the coarse angular resolution space-borne or ground-based surveys. These instruments have to be installed at the focal plane of the largest single-dish telescopes. In this context, we have constructed and deployed a multi-thousands pixels dual-band (150 and 260 GHz, respectively 2mm and 1.15mm wavelengths) camera to image an instantaneous field-of-view of 6.5arc-min and configurable to map the linear polarization at 260GHz. We are providing a detailed description of this instrument, named NIKA2 (New IRAM KID Arrays 2), in particular focusing on the cryogenics, the optics, the focal plane arrays based on Kinetic Inductance Detectors (KID) and the readout electronics. We are presenting the performance measured on the sky during the commissioning runs that took place between October 2015 and April 2017 at the 30-meter IRAM (Institut of Millimetric Radio Astronomy) telescope at Pico Veleta. NIKA2 has been successfully deployed and commissioned, performing in-line with the ambitious expectations. In particular, NIKA2 exhibits FWHM angular resolutions of around 11 and 17.5 arc-seconds at respectively 260 and 150GHz. The NEFD (Noise Equivalent Flux Densities) demonstrated on the maps are, at these two respective frequencies, 33 and 8 mJy*sqrt(s). A first successful science verification run has been achieved in April 2017. The instrument is currently offered to the astronomical community during the coming winter and will remain available for at least the next ten years.

astro-ph.IM

Lumped Element Kinetic Inductance Detectors for space applications

Kinetic Inductance Detectors (KID) are now routinely used in ground-based telescopes. Large arrays, deployed in formats up to kilopixels, exhibit state-of-the-art performance at millimeter (e.g. 120-300 GHz, NIKA and NIKA2 on the IRAM 30-meters) and sub-millimeter (e.g. 350-850 GHz AMKID on APEX) wavelengths. In view of future utilizations above the atmosphere, we have studied in detail the interaction of ionizing particles with LEKID (Lumped Element KID) arrays. We have constructed a dedicated cryogenic setup that allows to reproduce the typical observing conditions of a space-borne observatory. We will report the details and conclusions from a number of measurements. We give a brief description of our short term project, consisting in flying LEKID on a stratospheric balloon named B-SIDE.

astro-ph.IM

Analytical approach to optimizing alternating current biasing of bolometers

Bolometers are most often biased by alternating current (AC) in order to get rid of low-frequency noises that plague direct current (DC) amplification systems. When stray capacitance is present, the respon- sivity of the bolometer differs significantly from the expectations of the classical theories. We develop an analytical model that facilitates the optimization of the AC readout electronics design and tuning. This model is applied to cases similar to the bolometers in the Planck space mission. We study how the re- sponsivity and the noise equivalent power (NEP) of an AC biased bolometer depend on these essential parameters: bias current, heat sink temperature and background power, modulation frequency of the bias, and stray capacitance. We show that the optimal AC bias current in the bolometer is significantly different from that of the DC case as soon as a stray capacitance is present due to the difference in the electrothermal feedback. We also compare the performance of square and sine bias currents and show a slight theoretical advantage for the latter. This work resulted from the need to be able to predict the real behavior of AC biased bolometers in an extended range of working parameters. It proved to be applicable to optimize the tuning of the Planck High-Frequency Instrument bolometers.

astro-ph.IM

The impact of dust on the scaling properties of galaxy clusters

We investigate the effect of dust on the scaling properties of galaxy clusters based on hydrodynamic N-body simulations of structure formation. We have simulated five dust models plus a radiative cooling and adiabatic models using the same initial conditions for all runs. The numerical implementation of dust was based on the analytical computations of Montier and Giard (2004). We set up dust simulations to cover different combinations of dust parameters that put in evidence the effects of size and abundance of dust grains. Comparing our radiative plus dust cooling runs to a purely radiative cooling simulation we find that dust has an impact on cluster scaling relations. It mainly affects the normalisation of the scalings (and their evolution), whereas it introduces no significant differences on their slopes. The strength of the effect depends critically on the dust abundance and grain size parameters as well as on the cluster scaling. Indeed, cooling due to dust is effective at the cluster regime and has a stronger effect on the "baryon driven" statistical properties of clusters such as $L_{\rm X}-M$, $Y- M$, $S-M$ scaling relations. Major differences, relative to the radiative cooling model, are as high as 25% for the $L_{\rm X}-M$ normalisation, and about 10% for the $Y-M$ and $S-M$ normalisations at redshift zero. On the other hand, we find that dust has almost no impact on the "dark matter driven" $T_{\rm mw}-M$ scaling relation. The effects are found to be dependent in equal parts on both dust abundances and grain sizes distributions for the scalings investigated in this paper. Higher dust abundances and smaller grain sizes cause larger departures from the radiative cooling (i.e. with no dust) model.

astro-ph