Searcharxiv⌕ Search

arXiv subjects

Andrea Giachero

Publications and source records attributed to Andrea Giachero.

33 records · Page 2Linked to original sources

Assessment of few-hits machine learning classification algorithms for low energy physics in liquid argon detectors

The physics potential of massive liquid argon TPCs in the low-energy regime is still to be fully reaped because few-hits events encode information that can hardly be exploited by conventional classification algorithms. Machine learning (ML) techniques give their best in these types of classification problems. In this paper, we evaluate their performance against conventional (deterministic) algorithms. We demonstrate that both Convolutional Neural Networks (CNN) and Transformer-Encoder methods outperform deterministic algorithms in one of the most challenging classification problems of low-energy physics (single- versus double-beta events). We discuss the advantages and pitfalls of Transformer-Encoder methods versus CNN and employ these methods to optimize the detector parameters, with an emphasis on the DUNE Phase II detectors ("Module of Opportunity").

physics.ins-det↗

Nonlinear Behavior of Josephson Traveling Wave Parametric Amplifiers

Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providing a relevant bandwidth. This research is centered on a comprehensive numerical investigation of the JTWPA, without resorting to simplifications regarding the nonlinearity of the essential components. Specifically, this study focuses on a thorough examination of the system, characterized by coupled nonlinear differential equations representing all components of the device. Proper input and output signals at the device's boundaries are considered. The analysis of the output signals undergoing the parametric amplification process involves a detailed exploration of phase-space dynamics and Fourier spectral analysis of the output voltage. This study is conducted while considering the parameters ruling the response of the device under pump and signal excitations. In addition to the expected signal amplification, the findings reveal that the nonlinear nature of the system can give rise to unforeseen phenomena, depending on the system's operational conditions, which include: the generation of pump tone harmonics, modulation of the signal gain, and incommensurate frequency generation-effects that are not easily accommodated by simplistic linearized approaches

cond-mat.supr-con↗

Broadband parametric amplification in DARTWARS

Superconducting parametric amplifiers offer the capability to amplify feeble signals with extremely low levels of added noise, potentially reaching quantum-limited amplification. This characteristic makes them essential components in the realm of high-fidelity quantum computing and serves to propel advancements in the field of quantum sensing. In particular, Traveling-Wave Parametric Amplifiers (TWPAs) may be especially suitable for practical applications due to their multi-Gigahertz amplification bandwidth, a feature lacking in Josephson Parametric Amplifiers (JPAs), despite the latter being a more established technology. This paper presents recent developments of the DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project, focusing on the latest prototypes of Kinetic Inductance TWPAs (KITWPAs). The project aims to develop a KITWPA capable of achieving $20\,$ dB of amplification. To enhance the production yield, the first prototypes were fabricated with half the length and expected gain of the final device. In this paper, we present the results of the characterization of one of the half-length prototypes. The measurements revealed an average amplification of approximately $9\,$dB across a $2\,$GHz bandwidth for a KITWPA spanning $17\,$mm in length.

quant-ph↗

Development of KI-TWPAs for the DARTWARS project

Noise at the quantum limit over a broad bandwidth is a fundamental requirement for future cryogenic experiments for neutrino mass measurements, dark matter searches and Cosmic Microwave Background (CMB) measurements as well as for fast high-fidelity read-out of superconducting qubits. In the last years, Josephson Parametric Amplifiers (JPA) have demonstrated noise levels close to the quantum limit, but due to their narrow bandwidth, only few detectors or qubits per line can be read out in parallel. An alternative and innovative solution is based on superconducting parametric amplification exploiting the travelling-wave concept. Within the DARTWARS (Detector Array Readout with Travelling Wave AmplifieRS) project, we develop Kinetic Inductance Travelling-Wave Parametric Amplifiers (KI-TWPAs) for low temperature detectors and qubit read-out. KI-TWPAs are typically operated in a threewave mixing (3WM) mode and are characterised by a high gain, a high saturation power, a large amplification bandwidth and nearly quantum limited noise performance. The goal of the DARTWARS project is to optimise the KI-TWPA design, explore new materials, and investigate alternative fabrication processes in order to enhance the overall performance of the amplifier. In this contribution we present the advancements made by the DARTWARS collaboration to produce a working prototype of a KI-TWPA, from the fabrication to the characterisation.

quant-ph↗

Characterization of a Transmon Qubit in a 3D Cavity for Quantum Machine Learning and Photon Counting

In this paper we report the use of superconducting transmon qubit in a 3D cavity for quantum machine learning and photon counting applications. We first describe the realization and characterization of a transmon qubit coupled to a 3D resonator, providing a detailed description of the simulation framework and of the experimental measurement of important parameters, like the dispersive shift and the qubit anharmonicity. We then report on a Quantum Machine Learning application implemented on the single-qubit device to fit the u-quark parton distribution function of the proton. In the final section of the manuscript we present a new microwave photon detection scheme based on two qubits coupled to the same 3D resonator. This could in principle decrease the dark count rate, favouring applications like axion dark matter searches.

quant-ph↗

Design and simulation of a transmon qubit chip for Axion detection

Quantum Sensing is a rapidly expanding research field that finds one of its applications in Fundamental Physics, as the search for Dark Matter. Devices based on superconducting qubits have already been successfully applied in detecting few-GHz single photons via Quantum Non-Demolition measurement (QND). This technique allows us to perform repeatable measurements, bringing remarkable sensitivity improvements and dark count rate suppression in experiments based on high-precision microwave photon detection, such as for Axions and Dark Photons search. In this context, the INFN Qub-IT project goal is to realize an itinerant single-photon counter based on superconducting qubits that will exploit QND for enhancing Axion search experiments. In this study, we present Qub-IT's status towards the realization of its first superconducting qubit device, illustrating design and simulation procedures and the characterization of fabricated Coplanar Waveguide Resonators (CPWs) for readout. We match target qubit parameters and assess a few-percent level agreement between lumped and distributed element simulation models. We reach a maximum internal quality factor of 9.2x10^5 for -92 dBm on-chip readout power.

quant-ph↗

High kinetic inductance NbTiN films for quantum limited travelling wave parametric amplifiers

A wide-bandwidth and low-noise amplification chain in the microwave regime is crucial for the efficient read-out of quantum systems based on superconducting detectors, such as Microwave Kinetic Inductance Detectors (MKIDs), Transition Edge Sensors (TESs), Magnetic Microcalorimeters (MMCs), and RF cavities, as well as qubits. Kinetic Inductance Travelling Wave Parametric Amplifiers (KI-TWPAs) operated in a three-wave mixing fashion have demonstrated exceptional dynamic range and low-noise performance, approaching the quantum limit. These amplifiers can be fabricated using a single layer of a high kinetic inductance film as weakly dispersive artificial transmission lines, with the ability to control the phase-matched bandwidth through dispersion engineering. In this study, we present the optimisation of the rf sputter-deposition process of NbTiN films using a Nb80%T20 target, with the goal of achieving precise control over film characteristics, resulting in high kinetic inductance while maintaining a high transition temperature. The parameter landscape related to the different sputtering conditions, such as pressure, power, and nitrogen flow, has been explored and the film thickness has been used as a fine-tuning parameter to adjust the properties of the final NbTiN films used for the fabrication of KI-TWPAs. As a final result, we have obtained a NbTiN film with a kinetic inductance of 8.5 pH/sq which we have exploited to fabricate KI-TWPA prototype devices, showing promising amplification performance.

physics.app-ph↗

Sequence of penalties method to study excited states using VQE

We propose an extension of the Variational Quantum Eigensolver (VQE) that leads to more accurate energy estimations and can be used to study excited states. The method is based on the introduction of a sequence of increasing penalties in the cost function. This approach does not require circuit modifications and thus can be applied with no additional depth cost. Through numerical simulations, we show that we are able to produce variational states with desired physical properties, such as total spin and charge. We assess its performance both on classical simulators and on currently available quantum devices, calculating the potential energy curves of small molecular systems in different physical configurations. Finally, we compare our method to the original VQE and to another extension, obtaining a better agreement with exact simulations for both energy and targeted physical quantities.

quant-ph↗

First design of a superconducting qubit for the QUB-IT experiment

Quantum sensing is a rapidly growing field of research which is already improving sensitivity in fundamental physics experiments. The ability to control quantum devices to measure physical quantities received a major boost from superconducting qubits and the improved capacity in engineering and fabricating this type of devices. The goal of the QUB-IT project is to realize an itinerant single-photon counter exploiting Quantum Non Demolition (QND) measurements and entangled qubits, in order to surpass current devices in terms of efficiency and low dark-count rates. Such a detector has direct applications in Axion dark-matter experiments (such as QUAX[1]), which require the photon to travel along a transmission line before being measured. In this contribution we present the design and simulation of the first superconducting device consisting of a transmon qubit coupled to a resonator using Qiskit-Metal (IBM). Exploiting the Energy Participation Ratio (EPR) simulation we were able to extract the circuit Hamiltonian parameters, such as resonant frequencies, anharmonicity and qubit-resonator couplings.

quant-ph↗

The matrix optimum filter for Low Temperature Detectors dead-time reduction

Experiments aiming at high sensitivities usually demand for a very high statistics in order to reach more precise measurements. However, for those exploiting Low Temperature Detectors (LTDs), a high source activity may represent a drawback, if the events rate becomes comparable with the detector characteristic temporal response. Indeed, since commonly used optimum filtering approaches can only process LTDs signals well isolated in time, a non-negligible part of the recorded experimental data-set is discarded and hence constitute the dead-time. In the presented study we demonstrate that, thanks to the matrix optimum filtering approach, the dead-time of an experiment exploiting LTDs can be strongly reduced.

physics.data-an↗

An automated system to define the optimal operating settings of cryogenic calorimeters

Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of these detectors, both in terms of energy resolution and stability. In this paper we present a set of automatic measurements and analysis procedures for the characterization and optimization of the working configuration of the NTD thermistors. The presented procedures were developed for CUORE, an array of 988 cryogenic macro-calorimeters instrumented with NTD thermistors that has been taking data since 2017. These procedures made it possible to characterize a large number of detectors in a reliable way. They are suitable enough to be used also in other large arrays of cryogenic detectors, such as CUPID.

physics.ins-det↗

Electron-phonon coupling in Ti/TiN MKIDs multilayer microresonator

Over the last few years there has been a growing interest toward the use of superconducting microwave microresonators operated in quasi-thermal equilibrium mode, especially applied to single particle detection. Indeed, previous devices designed and tested by our group with X-ray sources in the keV range evidenced that several issues arise from the attempt of detection through athermal quasiparticles produced within direct strikes of X-rays in the superconductor material of the resonator. In order to prevent issues related to quasiparticles self-recombination and to avoid exchange of athermal phonons with the substrate, our group focused on the development of thermal superconducting microresonators. In this configuration resonators composed of multilayer films of Ti/TiN sense the temperature of an absorbing material. To maximize the thermal response, low critical temperature films are preferable. By lowering the critical temperature, though, the maximum probing power bearable by the resonators decrease abruptly because of the weakening of the electron-phonon coupling. A proper compromise has to be found in order to avoid signal to noise ratio degradation. In this contribution we report the latest measurement of the electron-phonon coupling.

physics.ins-det↗

Assess the neutrino mass with micro and macro calorimeter approach

Thanks to oscillation experiments it is now an established fact that neutrinos are massive particles. Yet, the assessment of neutrinos absolute mass scale is still an outstanding challenge in particle physics and cosmology as oscillation experiments are sensitive only to the squared mass differences of the three neutrino mass eigenstates. The mass hierarchy is not the only missing piece in the puzzle. Theories of neutrino mass generation call into play Majorana neutrinos and there are experimental observations pointing toward the existence of sterile neutrinos in addition to the three weakly interacting ones. Three experimental approaches are currently pursued: an indirect neutrino mass determination via cosmological observables, the search for neutrinoless double $β$-decay, and a direct measurement based on the kinematics of single $β$ or electron capture decays. Bolometers and calorimeters are low temperature detectors used in many applications, such as astrophysics, fast spectroscopy and particle physics. In particular, sensitive calorimeters play an important role in the neutrino mass measurement and in the search for the neutrinoless double $β$-decay. There has been great technical progress on low temperature detectors since they were proposed for neutrino physics experiments in 1984. This general detector paradigm can be implemented in devices as small as a micrometer for sub eV radiation or as large as 1 kg for MeV scale particles. Today this technique offers the high energy resolution and scalability required for leading edges and competitive experiments addressing the still open questions in neutrino physics.

physics.ins-det↗

CLARO-CMOS, a very low power ASIC for fast photon counting with pixellated photodetectors

The CLARO-CMOS is an application specific integrated circuit (ASIC) designed for fast photon counting with pixellated photodetectors such as multi-anode photomultiplier tubes (Ma-PMT), micro-channel plates (MCP), and silicon photomultipliers (SiPM). The first prototype has four channels, each with a charge sensitive amplifier with settable gain and a discriminator with settable threshold, providing fast hit information for each channel independently. The design was realized in a long-established, stable and inexpensive 0.35 um CMOS technology, and provides outstanding performance in terms of speed and power dissipation. The prototype consumes less than 1 mW per channel at low rate, and less than 2 mW at an event rate of 10 MHz per channel. The recovery time after each pulse is less than 25 ns for input signals within a factor of 10 above threshold. Input referred RMS noise is about 7.7 ke^- (1.2 fC) with an input capacitance of 3.3 pF. Thanks to the low noise and high speed, a timing resolution down to 10 ps RMS was measured for typical photomultiplier signals of a few million electrons, corresponding to the single photon response for these detectors.

physics.ins-det↗

Modeling high impedance connecting links and cables below 1 Hz

High impedance connecting links and cables are modeled at low frequency in terms of their impedance to ground and to neigbouring connecting links. The impedance is usually considered to be the parallel combination of a resistance and a capacitance. While this model is adequate at moderate and low frequency, it proved to be not satisfactory at very low frequency, in the fractions of Hz range. Deep characterization was carried out on some samples down to 10 uHz, showing that an additional contribution to capacitance can emerge. A model was developed to explain and account for this additional contribution.

physics.ins-det↗