Designing a Self-Decoupled 16 Channel Transmitter for Human Brain Magnetic Resonance Imaging at 447MHz

Transmitter arrays play a critical role in ultra high field Magnetic Resonance Imaging (MRI), especially given the advantages made possible via parallel transmission (pTx) techniques. One of the challenges in design and construction of transmit arrays has traditionally been finding effective strategies for decoupling elements of the transmit array. Here, we present the design of the first self-decoupled, loop-based transmit array for human brain MRI at 10.5T / 447MHz. We demonstrate, using full-wave electromagnetic simulations, effective decoupling of the transmit elements without requiring the conventional overlap or inductive decoupling techniques.

physics.med-ph

A Self-Decoupled 32 Channel Receive Array for Human Brain Magnetic Resonance Imaging at 10.5T

Purpose: Receive array layout, noise mitigation and B0 field strength are crucial contributors to signal-to-noise ratio (SNR) and parallel imaging performance. Here, we investigate SNR and parallel imaging gains at 10.5 Tesla (T) compared to 7T using 32-channel receive arrays at both fields. Methods: A self-decoupled 32-channel receive array for human brain imaging at 10.5T (10.5T-32Rx), consisting of 31 loops and one cloverleaf element, was co-designed and built in tandem with a 16-channel dual-row loop transmitter. Novel receive array design and self-decoupling techniques were implemented. Parallel imaging performance, in terms of SNR and noise amplification (g-factor), of the 10.5T-32Rx was compared to the performance of an industry-standard 32-channel receiver at 7T (7T-32Rx) via experimental phantom measurements. Results: Compared to the 7T-32Rx, the 10.5T-32Rx provided 1.46 times the central SNR and 2.08 times the peripheral SNR. Minimum inverse g-factor value of the 10.5T-32Rx (min(1/g) = 0.56) was 51% higher than that of the 7T-32Rx (min(1/g) = 0.37) with R=4x4 2D acceleration, resulting in significantly enhanced parallel imaging performance at 10.5T compared to 7T. The g-factor values of 10.5T-32Rx were on par with those of a 64-channel receiver at 7T, e.g. 1.8 versus 1.9, respectively, with R=4x4 axial acceleration. Conclusion: Experimental measurements demonstrated effective self-decoupling of the receive array as well as substantial gains in SNR and parallel imaging performance at 10.5T compared to 7T.

physics.med-ph

Transcranial Focused Ultrasound for BOLD fMRI Signal Modulation in Humans

Transcranial focused ultrasound (tFUS) is an emerging form of non-surgical human neuromodulation that confers advantages over existing electro and electromagnetic technologies by providing a superior spatial resolution on the millimeter scale as well as the capability to target sub-cortical structures non-invasively. An examination of the pairing of tFUS and blood oxygen level dependent (BOLD) functional MRI (fMRI) in humans is presented here.

q-bio.NC