Fabrication And Characterization Of High-Quality Nb/Al-AlO$_x$/Nb Cross-Type Josephson Tunnel Junctions Utilising CMP-based Planarisation Techniques

Josephson tunnel junctions (JJs) are the fundamental building blocks of today's most advanced superconducting electronic components, such as qubits and superconducting quantum interference devices (SQUIDs). Given the ongoing demand for scalability of these devices on the wafer-scale, it is crucial to control the fabrication process as precisely as possible to ensure uniform quality and reproducibility. Today, window-type JJs are often used in the production of DC SQUIDs and while they are reliable and reproducible, they suffer from alignment inaccuracies caused by photolithography and unavoidable parasitic capacitances, thus limiting the energy sensitivity of DC SQUIDs. These problems can be circumvented by producing JJs with cross-type geometry, which allows for smaller junction areas and eliminates parasitic capacitances. Here we discuss the fabrication of Nb/Al-AlOx/Nb-based cross-type JJs, where the trilayer is embedded in sputter-deposited SiO$_2$ to allow for planarisation of the structures and to ensure the reliable insulation of the sidewalls of the bottom electrode. Instead of lift-off processes that require a lot of time and potentially leave unwanted wings along the edges of microstructures behind that might compromise subsequent layers, we use chemical-mechanical polishing (CMP) for the removal of excess SiO$_2$. This is not only much faster, but produces smooth and uniform surfaces, which in turn effectively improves the reliability of our JJ production process resulting in a high yield of over $90\,\%$ on wafer-scale. In addition, we discuss the influence of fabrication details on the quality and electrical properties of our JJs with different junction areas down to $1\,\mathrm{\mu m} \times 1\,\mathrm{\mu m}$ distributed across the wafer and extract the junction specific quality parameters from their IV-characteristics and their Fraunhofer patterns.

cond-mat.supr-con

Nuclear Charge Radius of $^9$Be from Muonic Atom Spectroscopy Using a Microcalorimeter

The $2p\to1s$ transition energy in muonic $^9$Be was measured using a metallic magnetic calorimeter, resulting in $E_{2p\to 1s}=33\,391.48(34)\,$eV. The result is 30 times more precise than the previous best measurement and enables the extraction of the corresponding nuclear charge radius $r_c($$^9$Be$)=2.5506(51)\,$fm. It is $2.4$ times more precise than the commonly used value based on electron scattering and differs from it by $2.3$ times the combined uncertainties. This measurement represents the first determination of a nuclear charge radius using muonic x-ray spectroscopy with microcalorimeters.

nucl-ex

Improved limit on the effective electron neutrino mass with the ECHo-1k experiment

The effective electron neutrino mass can be determined by analyzing the endpoint region of the $^{163}$Ho electron capture spectrum, provided a measurement with high energy resolution and high statistics using calorimetric techniques. Here, the Electron Capture in $^{163}$Ho collaboration, ECHo, presents an analysis of the most precise $^{163}$Ho spectrum currently available, obtained with the ECHo-1k experiment and comprising about 200 million events. A very low background rate of $B=9.1(1.3)\times 10^{-6}$ /eV/pixel/day was achieved allowing for a reliable analysis of the endpoint region. The derived endpoint energy $Q = 2862(4)$ eV is in excellent agreement with the one independently determined via Penning-trap mass spectrometry of $Q=2863.2(6)$ eV [1]. The upper limit of the effective electron neutrino mass is improved by almost a factor 2 compared to the lowest current value [2], reaching $m_{\nu_\mathrm{e}} < 15 $ eV/c${^2}$ (90\% credible interval).

hep-ex

Quantum Electrodynamics in Strong Electromagnetic Fields: Substate Resolved K$\alpha$ Transition Energies in Helium-like Uranium

Using novel metallic magnetic calorimeter detectors at the CRYRING@ESR, we recorded X-ray spectra of stored and electron cooled helium-like uranium (U$^{90+}$) with an unmatched spectral resolution of close to 90 eV. This allowed for an accurate determination of the energies of all four components of the K$\alpha$ transitions in U$^{90+}$. We find good agreement with state-of-the-art bound-state QED calculations for the strong-field regime. Our results do not support any systematic deviation between experiment and theory in helium-like systems, the presence of which was subject of intense debates in recent years.

physics.atom-ph

MMC Array to Study X-ray Transitions in Muonic Atoms

The QUARTET collaboration aims to significantly improve the precision of the absolute nuclear charge radii of light nuclei from Li to Ne by using an array of metallic magnetic calorimeters to perform high-precision X-ray spectroscopy of low-lying states in muonic atoms. A proof-of-principle measurement with lithium, beryllium and boron is planned for fall 2023 at the Paul Scherrer Institute. We discuss the performance achieved with the maXs-30 detector module to be used. To place the detector close to the target chamber where the muon beam will impact the material under study, we have developed a new dilution refrigerator sidearm. We further discuss the expected efficiency given the transparency of the X-ray windows and the quantum efficiency of the detector. The expected muonic X-ray rate combined with the high resolving power and detection efficiency of the detector suggest that QUARTET will be able to study the de-excitation of light muonic atoms at an unprecedented level, increasing the relative energy resolution by up to a factor of 20 compared to conventional detector techniques.

physics.ins-det

Towards Precision Muonic X-Ray Measurements of Charge Radii of Light Nuclei

We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, $Z=1,2$) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei $3 \leq Z \leq 10$ using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.

physics.atom-ph

Development and characterisation of high-resolution microcalorimeter detectors for the ECHo-100k experiment

The goal of the ECHo experiment is a direct determination of the absolute scale of the neutrino mass by the analysis of the end-point region of the Ho-163 electron capture (EC) spectrum. The results of the first phase of the experiment, ECHo-1k, have paved the way for the current phase, ECHo-100k, which aims at a sensitivity below 2 eV on the effective electron neutrino mass. In order to reach this goal, a new generation of high-resolution magnetic microcalorimeters with embedded Ho-163 have been developed and characterised. The design has been optimised to meet all the challenging requirements of the ECHo-100k experimental phase, such as excellent energy resolution, wafer scale implantation and multi-chip operation with multiplexing read-out. We present the optimisation studies, the final design of the detector array and the first characterisation studies. The results demonstrate that the detectors fully match and even surpass the requirements for the current experimental phase, ECHo-100k.

physics.ins-det

Measuring Magnetic 1/f Noise in Superconducting Microstructures and the Fluctuation-Dissipation Theorem

The performance of superconducting devices like qubits, SQUIDs, and particle detectors is often limited by finite coherence times and 1/f noise. Various types of slow fluctuators in the Josephson junctions and the passive parts of these superconducting circuits can be the cause, and devices usually suffer from a combination of different noise sources, which are hard to disentangle and therefore hard to eliminate. One contribution is magnetic 1/f noise caused by fluctuating magnetic moments of magnetic impurities or dangling bonds in superconducting inductances, surface oxides, insulating oxide layers, and adsorbates. In an effort to further analyze such sources of noise, we have developed an experimental set-up to measure both the complex impedance of superconducting microstructures, and the overall noise picked up by these structures. This allows for important sanity checks by connecting both quantities via the fluctuation-dissipation theorem. Since these two measurements are sensitive to different types of noise, we are able to identify and quantify individual noise sources. The superconducting inductances under investigation form a Wheatstone-like bridge, read out by two independent cross-correlated dc-SQUID read-out chains. The resulting noise resolution lies beneath the quantum limit of the front-end SQUIDs and lets us measure noise caused by just a few ppm of impurities in close-by materials. We present measurements of the insulating SiO2 layers of our devices, and magnetically doped noble metal layers in the vicinity of the pickup coils at T = 40 mK - 800 mK and f = 1 Hz - 100 kHz.

cond-mat.supr-con

Muonic-Atom Spectroscopy and Impact on Nuclear Structure and Precision QED Theory

Recent progress in laser and x-ray spectroscopy of muonic atoms offers promising long-term possibilities at the intersection of atomic, nuclear and particle physics. In muonic hydrogen, laser spectroscopy measurements will determine the ground-state hyperfine splitting (HFS) and additionally improve the Lamb shift by a factor of 5. Precision spectroscopy with cryogenic microcalorimeters has the potential to significantly improve the charge radii of the light nuclei in the $Z=3-8$ range. Complementary progress in precision should be achieved on the theory of nucleon- and nuclear-structure effects. The impact of this muonic-atom spectroscopy program will be amplified by the upcoming results from H and He$^+$ spectroscopy, simple molecules such as HD$^+$ and Penning trap measurements. In this broader context, one can test ab-initio nuclear theories, bound-state QED for two- or three-body systems, and determine fundamental constants, such as the Rydberg ($R_\infty$) and the fine-structure ($α$) constants.

nucl-th

Data reduction for a calorimetrically measured $^{163}\mathrm{Ho}$ spectrum of the ECHo-1k experiment

The electron capture in $^{163}\mathrm{Ho}$ experiment (ECHo) is designed to directly measure the effective electron neutrino mass by analysing the endpoint region of the $^{163}\mathrm{Ho}$ electron capture spectrum. We present a data reduction scheme for the analysis of high statistics data acquired with the first phase of the ECHo experiment, ECHo-1k, to reliably infer the energy of $^{163}\mathrm{Ho}$ events and discard triggered noise or pile-up events. On a first level, the raw data is filtered purely based on the trigger time information of the acquired signals. On a second level, the time profile of each triggered event is analysed to identify the signals corresponding to a single energy deposition in the detector. We demonstrate that events not belonging to this category are discarded with an efficiency above 99.8%, with a minimal loss of $^{163}\mathrm{Ho}$ events of about 0.7%. While the filter using the trigger time information is completely energy independent, a slight energy dependence of the filter based on the time profile is precisely characterised. This data reduction protocol will be important to minimise systematic errors in the analysis of the $^{163}\mathrm{Ho}$ spectrum for the determination of the effective electron neutrino mass.

physics.ins-det

Flux ramp modulation based MHz frequency-division dc-SQUID multiplexer

We present a MHz frequency-division dc-SQUID multiplexer that is based on flux ramp modulation and a series array of $N$ identical current-sensing dc-SQUIDs with tightly coupled input coil. By running a periodic, sawtooth-shaped current signal through an additional modulation coil being tightly, but non-uniformly coupled to the individual SQUIDs, the voltage drop across the array changes according to the superposition of the flux-to-voltage characteristics of the individual SQUIDs within each cycle of the modulation signal. In this mode of operation, an input signal injected in the input coil of one of the SQUIDs and being quasi-static within a time frame adds a constant flux offset and leads to a phase shift of the associated SQUID characteristics. The latter is inherently proportional to the input signal and can be inferred by channelizing and down-converting the sampled array output voltage. Using a prototype multiplexer as well as a self-developed high-speed readout electronics for real-time phase determination, we demonstrate the simultaneous readout of four signal sources with MHz bandwidth per channel.

physics.ins-det

Specific Heat of Holmium in Gold and Silver at Low Temperatures

The specific heat of dilute alloys of holmium in gold and in silver plays a major role in the optimization of low temperature microcalorimeters with enclosed $^{163}\textrm{Ho}$, such as the ones developed for the neutrino mass experiment ECHo. We investigate alloys with atomic concentrations of $x_\textrm{Ho}=0.01\,\% - 4\,\%$ at temperatures between $10\,\textrm{mK}$ and $800\,\textrm{mK}$. Due to the large total angular momentum $J=8$ and nuclear spin $I=7/2$ of $\textrm{Ho}^{3+}$ ions, the specific heat of $\underline{\textrm{Au}}\textrm{:Ho}$ and $\underline{\textrm{Ag}}\textrm{:Ho}$ depends on the detailed interplay of various interactions, including contributions from the localized 4f electrons and nuclear contributions via hyperfine splitting. This makes it difficult to accurately determine the specific heat of these materials numerically. Instead, we measure their specific heat by using three experimental set-ups optimized for different concentration and temperature ranges. The results from measurements on six holmium alloys demonstrate that the specific heat of these materials is dominated by a large Schottky anomaly with its maximum at $T\approx 250\,\textrm{mK}$, which we attribute to hyperfine splitting and crystal field interactions. RKKY and dipole-dipole interactions between the holmium atoms cause additional, concentration-dependent effects. With regard to ECHo, we conclude that for typical operating temperatures of $T\leq 20\,\textrm{mK}$, silver holmium alloys with $x_\textrm{Ho}\gtrsim 1\,\%$ are suited best.

cond-mat.mtrl-sci

Measurement of the $^{229}$Th isomer energy with a magnetic micro-calorimeter

We present a measurement of the low-energy (0--60$\,$keV) $γ$ ray spectrum produced in the $α$-decay of $^{233}$U using a dedicated cryogenic magnetic micro-calorimeter. The energy resolution of $\sim$$10\,$eV, together with exceptional gain linearity, allow us to measure the energy of the low-lying isomeric state in $^{229}$Th using four complementary evaluation schemes. The most accurate scheme determines the $^{229}$Th isomer energy to be $8.10(17)\,$eV, corresponding to 153.1(37)$\,$nm, superseding in precision previous values based on $γ$ spectroscopy, and agreeing with a recent measurement based on internal conversion electrons. We also measure branching ratios of the relevant excited states to be $b_{29}=9.3(6)\%$ and $b_{42}=0.3(3)\%$.

nucl-ex

Development of a novel calorimetry setup based on metallic paramagnetic temperature sensors

We have developed a new micro-fabricated platform for the measurement of the specific heat of low heat capacity mg-sized metallic samples, such as superconductors, down to temperatures of as low as $10\,\mathrm{mK}$. It addresses challenging aspects of setups of this kind such as the thermal contact between sample and platform, the thermometer resolution, and an addenda heat capacity exceeding that of the samples of interest (typically $\mbox{nJ/K at }20\,\mbox{mK}$). The setup allows us to use the relaxation method, where the thermal relaxation following a well defined heat pulse is monitored to extract the specific heat. The sample platform ($5 \times 5\, \mathrm{mm^2}$) includes a micro-structured paramagnetic \underline{Ag}:Er temperature sensor, which is read out by a dc-SQUID via a superconducting flux transformer. In this way, a relative temperature precision of $30\,\mathrm{nK/\sqrt{Hz}}$ can be reached, while the addenda heat capacity falls well below $0.5\,\mathrm{nJ/K}$ for $T < 300\,\mathrm{mK}$. A gold-coated mounting area ($4.4 \times 3 \, \mathrm{mm^2}$) is included to improve the thermal contact between sample and platform.

physics.ins-det

Dephasing of Atomic Tunneling by Nuclear Quadrupoles

Recent experiments revealed a most surprising magnetic-field dependence of coherent echoes in amorphous solids. We show that a novel dephasing mechanism involving nuclear quadrupole moments is the origin of the observed magnetic-field dependence.

cond-mat.dis-nn

Low temperature dipolar echo in amorphous dielectrics: Significance of relaxation and decoherence free two level systems

The nature of dielectric echoes in amorphous solids at low temperatures is investigated. It is shown that at long delay times the echo amplitude is determined by a small subset of two level systems (TLS) having negligible relaxation and decoherence because of their weak coupling to phonons. The echo decay can then be described approximately by power law time dependencies with different powers at times longer and shorter than the typical TLS relaxation time. The theory is applied to recent measurements of two and three pulse dipolar echo in borosilicate glass BK7 and provides a perfect data fit in the broad time and temperature ranges under the assumption that there exist two TLS relaxation mechanisms due to TLS-phonons and TLS-TLS interaction. This interpretation is consistent with the previous experimental and theoretical investigations. Further experiments verifying the theory predictions are suggested.