Searcharxiv⌕ Search

arXiv subjects

Andrei Azhakin

Publications and source records attributed to Andrei Azhakin.

2 recordsLinked to original sources

CCGeant4: charge-state-resolved transport and energy-loss fluctuations of relativistic heavy ions in Geant4

CCGeant4 models energy-loss fluctuations of heavy ions in Geant4, accounting for both charge exchange and relativistic corrections to electron scattering beyond the first Born approximation. We use GLOBAL cross sections for electron capture and loss, ATIMA equilibrium stopping powers and charge-dependent delta-electron spectra calculated from the Dirac equation in a frozen-shell potential. The package also supports tabulated elastic ion-nucleus scattering. The silicon example includes interference between Coulomb and nuclear scattering amplitudes. We compare charge evolution with GLOBAL and energy-loss spectra with MOCADI for matched beams and targets. Experimental comparisons cover published energy-loss measurements and several measurements of energy deposited by xenon ions in silicon. For uranium at 800 MeV/u, the energy-loss variances from our Dirac configuration agree with published screened-ion calculations to within 4% in Be, Al and Pb. Both calculations lie within the reported experimental uncertainties for all three targets, while calculated bismuth spectra in silver are narrower than measured. Calculations in thin silicon layers show that delta-electron escape can make deposited-energy distributions substantially narrower than primary-ion energy-loss distributions, highlighting the importance of secondary-electron transport for detector-response modelling. The distribution includes the Geant4 source patch, the transport tables and their converters, and a runnable example.

physics.ins-det↗

Xenon energy-deposition widths in silicon: measurements and Geant4 comparisons

Energy-deposition fluctuations determine the isotope-separation capability of multilayer silicon detectors. We measure the central peak widths of $^{124}$Xe signals in 300- and 675-micrometre silicon layers at incident energies of approximately 152-274 MeV per nucleon and compare them with Geant4 11.4.0 electromagnetic option 4 (emopt4) and a calculation with explicit charge exchange. In the 300-micrometre detector, the emopt4 relative width of 1.844% exceeds the unselected experimental width of 1.407% by 31% and the selected width of 1.060% by 74%. For the 675-micrometre detector, selection windows around the downstream-signal peak, each approximately ten fitted first-plane standard deviations wide, give experimental upper estimates of 0.66-0.74%, compared with emopt4 predictions of 1.01-1.24%. Explicit charge-state transport gives widths of 0.889-0.932% for the thinner layer, depending on the incident charge distribution, and 0.59-0.63% for the thicker layer. These predictions are consistent with the experimental upper estimates, while emopt4 overestimates the widths for both thicknesses throughout the studied energy interval.

physics.ins-det↗