Searcharxiv⌕ Search

arXiv subjects

Andrei Nomerotski

Publications and source records attributed to Andrei Nomerotski.

At least 55 records · Page 3Linked to original sources

Novel imaging technique for $α$-particles using a fast optical camera

A new imaging technique for $α$-particles using a fast optical camera focused on a thin scintillator is presented. As $α$-particles interact in a thin layer of LYSO fast scintillator, they produce a localized flash of light. The light is collected with a lens to an intensified optical camera, Tpx3Cam, with single photon sensitivity and excellent spatial & temporal resolutions. The interactions of photons with the camera is reconstructed by means of a custom algorithm, capable of discriminating single photons using time and spatial information.

physics.ins-det↗

Multivariate Discrimination in Quantum Target Detection

We describe a simple multivariate technique of likelihood ratios for improved discrimination of signal and background in multi-dimensional quantum target detection. The technique combines two independent variables, time difference and summed energy, of a photon pair from the spontaneous parametric down-conversion source into an optimal discriminant. The discriminant performance was studied in experimental data and in Monte-Carlo modelling with clear improvement shown compared to previous techniques. As novel detectors become available, we expect this type of multivariate analysis to become increasingly important in multi-dimensional quantum optics.

quant-ph↗

Counting of Hong-Ou-Mandel Bunched Optical Photons Using a Fast Pixel Camera

The uses of a silicon-pixel camera with very good time resolution ($\sim$nanosecond) for detecting multiple, bunched optical photons is explored. We present characteristics of the camera and describe experiments proving its counting capabilities. We use a spontaneous parametric down-conversion source to generate correlated photon pairs, and exploit the Hong-Ou-Mandel interference effect in a fiber-coupled beam splitter to bunch the pair onto the same output fiber. It is shown that the time and spatial resolution of the camera enables independent detection of two photons emerging simultaneously from a single spatial mode.

quant-ph↗

Multidimensional quantum-enhanced target detection via spectro-temporal correlation measurements

In this work we investigate quantum-enhanced target detection in the presence of large background noise using multidimensional quantum correlations between photon pairs generated through spontaneous parametric down-conversion. Until now similar experiments have only utilized one of the photon pairs' many degrees of freedom such as temporal correlations and photon number correlations. Here, we utilized both temporal and spectral correlations of the photon pairs and achieved over an order of magnitude reduction to the background noise and in turn significant reduction to data acquisition time when compared to utilizing only temporal modes. We believe this work represents an important step in realizing a practical, real-time quantum-enhanced target detection system. The demonstrated technique will also be of importance in many other quantum sensing applications and quantum communications.

quant-ph↗

PymePix: A python library for SPIDR readout of Timepix3

PymePix is a new Python 3 library that provides control and acquisition for the Timepix3-SPIDR hardware. The rich set of data-structures and intuitive routines reduces time and coding effort to quickly configure, acquire, and visualize data from Timepix3. The highly extensible high-performance data-pipeline allows for alteration of the Timepix3 datastream into a form that is convinient for the user. This library is intended to be easily inserted into a standard scientific software stack as well as to allow for more direct interaction of Timepix3 with interactive flavors of Python. Included with the library are two example programs using PymePix: pymepix-acq is a command line control and acquisition program that can capture UDP packets and decode them into pixels and triggers. The second is PymePix-Viewer, an online control and data-acquisition program for general use, but with features geared toward mass-spectroscopy and ion imaging.

physics.ins-det↗

Research and Development for HI Intensity Mapping

Development of the hardware, data analysis, and simulation techniques for large compact radio arrays dedicated to mapping the 21 cm line of neutral hydrogen gas has proven to be more difficult than imagined twenty years ago when such telescopes were first proposed. Despite tremendous technical and methodological advances, there are several outstanding questions on how to optimally calibrate and analyze such data. On the positive side, it has become clear that the outstanding issues are purely technical in nature and can be solved with sufficient development activity. Such activity will enable science across redshifts, from early galaxy evolution in the pre-reionization era to dark energy evolution at low redshift.

astro-ph.IM↗

Quantum Networks For Open Science

The United States Department of Energy convened the Quantum Networks for Open Science (QNOS) Workshop in September 2018. The workshop was primarily focused on quantum networks optimized for scientific applications with the expectation that the resulting quantum networks could be extended to lay the groundwork for a generalized network that will evolve into a quantum internet.

quant-ph↗

The Next Generation of Cosmological Measurements with Type Ia Supernovae

While Type Ia Supernovae (SNe Ia) are one of the most mature cosmological probes, the next era promises to be extremely exciting in the number of different ways SNe Ia are used to measure various cosmological parameters. Here we review the experiments in the 2020s that will yield orders of magnitudes more SNe Ia, and the new understandings and capabilities to constrain systematic uncertainties at a level to match these statistics. We then discuss five different cosmological probes with SNe Ia: the conventional Hubble diagram for measuring dark energy properties, the distance ladder for measuring the Hubble constant, peculiar velocities and weak lensing for measuring sigma8 and strong-lens measurements of H0 and other cosmological parameters. For each of these probes, we discuss the experiments that will provide the best measurements and also the SN Ia-related systematics that affect each one.

astro-ph.CO↗

Messengers from the Early Universe: Cosmic Neutrinos and Other Light Relics

The hot dense environment of the early universe is known to have produced large numbers of baryons, photons, and neutrinos. These extreme conditions may have also produced other long-lived species, including new light particles (such as axions or sterile neutrinos) or gravitational waves. The gravitational effects of any such light relics can be observed through their unique imprint in the cosmic microwave background (CMB), the large-scale structure, and the primordial light element abundances, and are important in determining the initial conditions of the universe. We argue that future cosmological observations, in particular improved maps of the CMB on small angular scales, can be orders of magnitude more sensitive for probing the thermal history of the early universe than current experiments. These observations offer a unique and broad discovery space for new physics in the dark sector and beyond, even when its effects would not be visible in terrestrial experiments or in astrophysical environments. A detection of an excess light relic abundance would be a clear indication of new physics and would provide the first direct information about the universe between the times of reheating and neutrino decoupling one second later.

astro-ph.CO↗

Spatial characterization of photonic polarization entanglement using a Tpx3Cam intensified fast-camera

Scalable technologies to characterize the performance of quantum devices are crucial to creating large quantum networks and quantum processing units. Chief among the resources of quantum information processing is entanglement. Here we describe the full temporal and spatial characterization of polarization-entangled photons produced by Spontaneous Parametric Down Conversions using an intensified high-speed optical camera, Tpx3Cam. This novel technique allows for precise determination of Bell inequality parameters with minimal technical overhead, as well as novel characterization methods of the spatial distribution of entangled quantum information. This could lead to multiple applications in Quantum Information Science, opening new perspectives for the scalability of quantum experiments.

quant-ph↗

Quantum Sensing for High Energy Physics

Report of the first workshop to identify approaches and techniques in the domain of quantum sensing that can be utilized by future High Energy Physics applications to further the scientific goals of High Energy Physics.

hep-ex↗

Coincidence velocity map imaging using Tpx3Cam, a time stamping optical camera with 1.5 ns timing resolution

We demonstrate a coincidence velocity map imaging apparatus equipped with a novel time stamping fast optical camera, Tpx3Cam, whose high sensitivity and ns timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.

physics.ins-det↗

An automated system to measure the quantum efficiency of CCDs for astronomy

We describe a system to measure the Quantum Efficiency in the wavelength range of 300 nm to 1100 nm of 40x40 mm n-channel CCD sensors for the construction of the 3.2 gigapixel LSST focal plane. The technique uses a series of instrument to create a very uniform flux of photons of controllable intensity in the wavelength range of interest across the face the sensor. This allows the absolute Quantum Efficiency to be measured with an accuracy in the 7% range. This system will be part of a production facility at Brookhaven National Lab for the basic component of the LSST camera.

astro-ph.IM↗

High fidelity point-spread function retrieval in the presence of electrostatic, hysteretic pixel response

We employ electrostatic conversion drift calculations to match CCD pixel signal covariances observed in flat field exposures acquired using candidate sensor devices for the LSST Camera. We thus constrain pixel geometry distortions present at the end of integration, based on signal images recorded. We use available data from several operational voltage parameter settings to validate our understanding. Our primary goal is to optimize flux point-spread function (FPSF) estimation quantitatively, and thereby minimize sensor-induced errors which may limit performance in precision astronomy applications. We consider alternative compensation scenarios that will take maximum advantage of our understanding of this underlying mechanism in data processing pipelines currently under development. To quantitatively capture the pixel response in high-contrast/high dynamic range operational extrema, we propose herein some straightforward laboratory tests that involve altering the time order of source illumination on sensors, within individual test exposures. Hence the word {\it hysteretic} in the title of this paper.

astro-ph.IM↗

A framework for modeling the detailed optical response of thick, multiple segment, large format sensors for precision astronomy applications

Near-future astronomical survey experiments, such as LSST, possess system requirements of unprecedented fidelity that span photometry, astrometry and shape transfer. Some of these requirements flow directly to the array of science imaging sensors at the focal plane. Availability of high quality characterization data acquired in the course of our sensor development program has given us an opportunity to develop and test a framework for simulation and modeling that is based on a limited set of physical and geometric effects. In this paper we describe those models, provide quantitative comparisons between data and modeled response, and extrapolate the response model to predict imaging array response to astronomical exposure. The emergent picture departs from the notion of a fixed, rectilinear grid that maps photo-conversions to the potential well of the channel. In place of that, we have a situation where structures from device fabrication, local silicon bulk resistivity variations and photo-converted carrier patterns still accumulating at the channel, together influence and distort positions within the photosensitive volume that map to pixel boundaries. Strategies for efficient extraction of modeling parameters from routinely acquired characterization data are described. Methods for high fidelity illumination/image distribution parameter retrieval, in the presence of such distortions, are also discussed.

astro-ph.IM↗

The International Linear Collider Technical Design Report - Volume 2: Physics

The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.

hep-ph↗

Development of Single- and Double-sided Ladders for the ILD Vertex Detectors

We discuss two projects exploring the integration of thin CMOS pixel sensors in order to prototype ladders matching the geometry needed for the ILD vertex detector. The PLUME project has designed and fabricated full-size and fully functional double- sided layers which currently reach 0.6 % X0 and aim for 0.3 % X0 in mid-2012. Another approach, SERNWIETE, consists in wrapping the sensors in a polyimide-based micro-cable to obtain a supportless single-sided ladder with a material budget around 0.15 % X0. First promising samples have been produced and the full-size prototype is expected in spring 2012.

physics.ins-det↗