SearcharxivSearch

arXiv subjects

Andrew Bear

Publications and source records attributed to Andrew Bear.

2 recordsLinked to original sources

Dark matter searches with a 13 meV threshold superconducting sensor array

Many well-motivated dark matter models predict meV-scale energy deposits in interactions with terrestrial experiments, but this regime is challenging to probe due to a lack of mature single-quantum detectors. Here we report results from QUALIPHIDE (QUAntum LImited PHotons In the Dark Experiment), a cryogenic dark matter search using a $41$-pixel array of energy-resolving microwave kinetic inductance detectors with a $13$ meV threshold, simultaneously used to look for both conversion photons from THz wavelength hidden photon dark matter and phonons from particle-like light dark matter interactions. The experimental design, with on- and off-focus pixels for the hidden photon search, allows for a data-driven background model, giving the experiment discovery potential. A blind analysis of $22$ hours of data shows no significant excess, setting the strongest constraints on the hidden photon kinetic mixing parameter $\chi$ over the mass range of $13$-$90$ meV/$c^2$, reaching $1.5\times10^{-12}$ at $50$ meV/$c^2$. These data also yield among the first terrestrial limits on dark matter scattering off nuclei and electrons, down to $5$ MeV/$c^2$ and $20$ keV/$c^2$, respectively. The low threshold also enables future study of the low-energy excess limiting cryogenic detectors and, as we project, will allow for a terahertz-scale QCD axion search with a magnetic field.

hep-ex

In Situ Interferometric Spatial Mapping Of A Microwave Kinetic Inductance Detector Array

We present a method of spatially mapping microwave kinetic inductance detector (MKID) arrays, in a dark setup. MKIDs are superconducting natively multiplexed resonators which enable kilopixel arrays, such as for the proposed Probe far-Infrared Mission for Astrophysics (PRIMA). In such telescope applications one must map the spatial location of each MKID with their individual resonance frequencies. Traditional LED arrays or beam-mapping methods become increasingly difficult as pixel spacing decreases, e.g., 900 {\mu}m separated MKIDs in the spectrometer module of PRIMA. Our new mapping technique uses a cryogenic interferometer in reflection mode. As on-resonance signals reflect from an MKID, they accrue a phase proportional to the path-length, exactly corresponding to their physical distance on the feedline. Specifically, we use a superconducting transmission line that has nonlinear kinetic inductance. The slow-wave structure of this nonlinear device is designed to have a signal speed of 0.64% the speed of light, enabling a compact system. Current biasing this line allows for varying the wave speed and ensuring that the phase measured is periodic within a nulling interferometric mode. Using this setup, we measure a length ordering that reflects the bimodal MKID distribution of a 44 pixel array of MKIDs designed for PRIMA which contains the same spacing as the final kilopixel array design.

astro-ph.IM