SearcharxivSearch

arXiv subjects

Andrew J. Berger

Publications and source records attributed to Andrew J. Berger.

8 recordsLinked to original sources

Machine learning reconstruction of digit bone Raman spectra enables noninvasive transcutaneous detection of systemic osteoporosis

Osteoporosis, a major global epidemic, often goes undetected until a fracture occurs, largely due to poor access to screening using gold standard methods, such as dual-energy X-ray absorptiometry (DXA). As a potential nonionizing radiation alternative, we present a transcutaneous spatially offset Raman spectroscopy (SORS) approach combined with machine learning (ML) to recover bone spectra through overlying soft tissue and extract diagnostic information. In a human cadaveric study spanning normal, osteopenic, and osteoporotic donors, we acquired paired Raman measurements from transcutaneous fingers at multiple spatial offsets (0, 3, and 6 mm) and from the corresponding exposed finger bones. Using this paired dataset, supervised machine-learning models were trained to reconstruct exposed-bone Raman spectra from transcutaneous measurements, enabling direct recovery of bone biochemical signatures from transcutaneous tissue. The ML predicted bone spectra preserved physiologically meaningful Raman features and demonstrated statistically significant differences between normal and osteoporotic groups across four key Raman-derived metrics (p < 0.05), representing, to our knowledge, the first demonstration of transcutaneous Raman discrimination between clinically established bone-health categories in a human cadaveric study. The ML-predicted spectra further correlated with distal-radius DXA T-scores (r = 0.73, RMSECV = 1.4), approaching the performance achieved using exposed-bone measurements (r = 0.9, RMSECV = 0.8). Finally, preliminary in vivo measurements from two volunteers revealed clear bone-related transcutaneous spectral features consistent with cadaveric data, supporting translational feasibility. Together, these results establish a foundation for nonionizing radiation, transcutaneous Raman assessment of bone health using supervised spectral extraction from accessible measurement sites

physics.med-ph

Predicting Wrist Osteoporosis from excised human finger bones using spatially offset Raman spectroscopy, A Cadaveric Study

Osteoporosis and osteopenia remain vastly underdiagnosed. Current clinical screening relies almost exclusively on dual-energy X-ray absorptiometry (DXA), which measures bone mineral density (BMD) but fails to capture the compositional changes that lead to BMD loss. We investigated whether Spatially Offset Raman Spectroscopy (SORS) applied to excised finger bones can assess subsurface biochemical markers capable of diagnosing osteoporosis and osteopenia and predicting wrist DXA T-scores. Raman spectra were acquired ex vivo on the mid-shaft of the proximal phalanx of the second digit from 25 female cadavers spanning the three T-score categories (n=8 normal, n=6 osteopenic, and n=11 osteoporotic) at spatial offsets of 0, 3, and 6 mm from a laser irradiation spot. After normalizing spectra to the PO43- peak, group-averaged spectra of the three categories, measured at 3-mm offset, showed clear differences in the CO32-, Amide III, CH2, and Amide I bands. Quantitatively, four out of five mineral-to-matrix ratios differed significantly (p < 0.05) between normal and osteopenic bone, and between osteopenic and osteoporotic bone, and all five ratios showed significant differences between normal and osteoporotic bone. In contrast, the 0-mm offset suffered diminished contrast, and the 6-mm offset did not enhance discrimination between different groups, compared with the 3-mm offset. A leave-one-out, partial-least-squares regression model built from the 3-mm spectra predicted distal radius DXA T-score with a Pearson correlation of r = 0.85 and a root-mean-square error of cross-validation of 1 T-score units, correctly classifying 92% of specimens.

physics.med-ph

Calibration technique for suppressing residual etalon artifacts in slit-averaged Raman spectroscopy

Back-illuminated charged-coupled device (BI-CCD) arrays increase quantum efficiency but also amplify etaloning, a multiplicative, wavelength-dependent fixed-pattern effect. When spectral data from hundreds of BI-CCD rows are combined, the averaged spectrum will generally appear etalon-free. This can mask substantial etaloning at the row level, even if the BI-CCD has been treated to suppress the effect. This Note compares two methods of etalon correction, one with simple averaging and one with row-by-row calibration using a fluorescence standard. Two BI-CCD arrays, both roughened by the supplier to reduce etaloning, were used to acquire Raman spectra of murine bone specimens. For one array, etaloning was the dominant source of noise under the exposure conditions chosen, even for the averaged spectrum across all rows; near-infrared-excited Raman peaks were noticeably affected. In this case, row-by-row calibration improved the spectral quality of the average spectrum. The other CCD's performance was shot-noise limited and therefore received no benefit from the extra calibration. The different results highlight the importance of checking for and correcting row-level fixed pattern when measuring weak Raman signals in the presence of a large fluorescence background.

physics.optics

Determination of spin Hall effect and spin diffusion length of Pt from self-consistent fitting of damping enhancement and inverse spin-orbit torque measurements

Understanding the evolution of spin-orbit torque (SOT) with increasing heavy-metal thickness in ferromagnet/normal metal (FM/NM) bilayers is critical for the development of magnetic memory based on SOT. However, several experiments have revealed an apparent discrepancy between damping enhancement and damping-like SOT regarding their dependence on NM thickness. Here, using linewidth and phase-resolved amplitude analysis of vector network analyzer ferromagnetic resonance (VNA-FMR) measurements, we simultaneously extract damping enhancement and both field-like and damping-like inverse SOT in Ni$_{80}$Fe$_{20}$/Pt bilayers as a function of Pt thickness. By enforcing an interpretation of the data which satisfies Onsager reciprocity, we find that both the damping enhancement and damping-like inverse SOT can be described by a single spin diffusion length ($\approx$ 4 nm), and that we can separate the spin pumping and spin memory loss (SML) contributions to the total damping. This analysis indicates that less than 40% of the angular momentum pumped by FMR through the Ni$_{80}$Fe$_{20}$/Pt interface is transported as spin current into the Pt. On account of the SML and corresponding reduction in total spin current available for spin-charge transduction in the Pt, we determine the Pt spin Hall conductivity ($σ_\mathrm{SH} = (2.36 \pm 0.04)\times10^6 Ω^{-1} \mathrm{m}^{-1}$) and bulk spin Hall angle ($θ_\mathrm{SH}=0.387 \pm0.008$) to be larger than commonly-cited values. These results suggest that Pt can be an extremely useful source of SOT if the FM/NM interface can be engineered to minimize SML. Lastly, we find that self-consistent fitting of the damping and SOT data is best achieved by a model with Elliott-Yafet spin relaxation and extrinsic inverse spin Hall effect, such that both the spin diffusion length and spin Hall conductivity are proportional to the Pt charge conductivity.

cond-mat.mes-hall

Inductive detection of field-like and damping-like AC inverse spin-orbit torques in ferromagnet/normal metal bilayers

Functional spintronic devices rely on spin-charge interconversion effects, such as the reciprocal processes of electric field-driven spin torque and magnetization dynamics-driven spin and charge flow. Both damping-like and field-like spin-orbit torques have been observed in the forward process of current-driven spin torque and damping-like inverse spin-orbit torque has been well-studied via spin pumping into heavy metal layers. Here we demonstrate that established microwave transmission spectroscopy of ferromagnet/normal metal bilayers under ferromagnetic resonance can be used to inductively detect the AC charge currents driven by the inverse spin-charge conversion processes. This technique relies on vector network analyzer ferromagnetic resonance (VNA-FMR) measurements. We show that in addition to the commonly-extracted spectroscopic information, VNA-FMR measurements can be used to quantify the magnitude and phase of all AC charge currents in the sample, including those due to spin pumping and spin-charge conversion. Our findings reveal that Ni$_{80}$Fe$_{20}$/Pt bilayers exhibit both damping-like and field-like inverse spin-orbit torques. While the magnitudes of both the damping-like and field-like inverse spin-orbit torque are of comparable scale to prior reported values for similar material systems, we observed a significant dependence of the damping-like magnitude on the order of deposition. This suggests interface quality plays an important role in the overall strength of the damping-like spin-to-charge conversion.

cond-mat.mtrl-sci

Correlating spin transport and electrode magnetization in a graphene spin valve: simultaneous magnetic microscopy and non-local measurements

Using simultaneous magnetic force microscopy (MFM) and transport measurements of a graphene spin valve, we correlate the non-local spin signal with the magnetization of the device electrodes. The imaged magnetization states corroborate the influence of each electrode within a one-dimensional spin transport model and provide evidence linking domain wall pinning to additional features in the transport signal.

cond-mat.mes-hall

A versatile LabVIEW and FPGA-based scanned probe microscope for in-operando electronic device characterization

Understanding the complex properties of electronic and spintronic devices at the micro- and nano-scale is a topic of intense current interest as it becomes increasingly important for scientific progress and technological applications. In-operando characterization of such devices by scanned probe techniques is particularly well-suited for the microscopic study of these properties. We have developed a scanned probe microscope (SPM) which is capable of both standard force imaging (atomic, magnetic, electrostatic) and simultaneous electrical transport measurements. We utilize flexible and inexpensive FPGA (field programmable gate array) hardware and a custom software framework developed in National Instrument's LabVIEW environment to perform the various aspects of microscope operation and device measurement. The FPGA-based approach enables sensitive, real-time cantilever frequency-shift detection. Using this system, we demonstrate electrostatic force microscopy of an electrically-biased graphene FET device. The combination of SPM and electrical transport also enables imaging of the transport response to a localized perturbation provided by the scanned cantilever tip. Facilitated by the broad presence of LabVIEW in the experimental sciences and the openness of our software solution, our system permits a wide variety of combined scanning and transport measurements by providing standardized interfaces and flexible access to all aspects of a measurement (input and output signals, and processed data). Our system also enables precise control of timing (synchronization of scanning and transport operations) and implementation of sophisticated feedback protocols, and thus should be broadly interesting and useful to practitioners in the field.

physics.ins-det

Off-Resonant Manipulation of Spins in Diamond via Precessing Magnetization of a Proximal Ferromagnet

We report the manipulation of nitrogen vacancy (NV) spins in diamond when nearby ferrimagnetic insulator, yttrium iron garnet, is driven into precession. The change in NV spin polarization, as measured by changes in photoluminescence, is comparable in magnitude to that from conventional optically detected magnetic resonance, but relies on a distinct mechanism as it occurs at a microwave frequency far removed from the magnetic resonance frequency of the NV spin. This observation presents a new approach to transferring ferromagnetic spin information into a paramagnet and then transducing the response into a robust optical signal. It also opens new avenues for studying ferromagnetism and spin transport at the nanoscale.

cond-mat.mes-hall