SearcharxivSearch

arXiv subjects

Andrew K. Yi

Publications and source records attributed to Andrew K. Yi.

8 recordsLinked to original sources

Extended Haloscope Search and Exclusion of a Candidate Signal near 1.036 GHz

We report a follow-up axion haloscope search near 1.036 GHz that completes and extends our previous work [Phys. Rev. X 14, 031023 (2024)], in which a portion of the HEMT-based data could not be analyzed due to unrecorded experimental information. While recovering this dataset, we identified an excess near 1.036 GHz that satisfied our candidate-selection criteria, motivating dedicated validation studies, including independent cross-checks and re-examination with the original apparatus. The excess did not persist under these investigations and was not confirmed as an axion dark-matter signal. We subsequently extended the search over a 20-MHz band surrounding the candidate using a quantum-noise-limited amplifier, achieving sensitivity close to the Dine-Fischler-Srednicki-Zhitnitsky benchmark. In the absence of a confirmed signal, we set improved 90% confidence-level upper limits on the axion-photon coupling over the frequency range 1.026-1.045 GHz. This work highlights the importance of robust candidate-validation strategies as haloscope searches approach discovery-level sensitivity.

hep-ex

A Non-Foster Superconducting Broadband Matching Network

The nonlinear inductance of the Josephson junction has enabled the development of a wide range of continuous-variable amplifiers and qubit-based devices with unprecedented sensitivity. We present an alternative use of the Josephson junction in the context of broadband impedance matching. The idea poses a potential solution to a longstanding problem in the field of high energy particle physics. The axion, a compelling candidate for the dark matter, converts to a weak electromagnetic signal at an as-yet unknown frequency. As such, the ideal axion detector does not compromise bandwidth for sensitivity, a trade-off intrinsic to all linear, time-invariant and passive circuits. We propose a circuit that uses a Josephson junction in an impedance matching network to overcome these gain-bandwidth constraints and increase the scan rate of axion searches. The Josephson junction can be biased to exhibit negative inductance capable of canceling geometric inductance similar to a capacitor but across a wider frequency range.

physics.ins-det

Axion dark matter searches from the standard halo over the tidal stream to the big flow

The sensitivity of axion dark matter searches depends on the signal window that results from the velocity dispersion of axion dark matter. Since the ratio of signal windows is about 6500 between the standard halo and the big flow axion dark matter, each axion dark matter search usually uses a separate data acquisition (DAQ) channel with a different frequency resolution bandwidth (RBW). In this work, we demonstrate axion dark matter searches covering the standard halo, the tidal stream, and the big flow employing a DAQ channel starting with a single high resolution RBW, without sacrificing the DAQ efficiency, where the DAQ process includes online fast Fourier transforms and writing the outputs to disk. Assuming the total amount of data is sensitive to Dine-Fischler-Srednicki-Zhitnitskii (DFSZ) axion dark matter that follows the standard halo model and makes up 100\% of the local dark matter density, the same data can also be used for the tidal stream and the big flow axion dark matter searches that would be sensitive to DFSZ axion dark matter that constitute 19.2\% and 12.4\% of the local dark matter densities, respectively, at a 90\% confidence level. We also report that the filtering of the individual power spectra acquired with a relatively high resolution RBW e.g., for the big flow search can prevent a possible significant degradation in the signal to noise ratio from the searches in the lower resolution RBW's, i.e., the standard halo and tidal stream searches.

astro-ph.CO

Asymmetrical cavity design that bypasses mode mixings in axion haloscope experiments

Microwave cavities used in axion haloscope experiments typically employ a tuning rod as a means to widen the range of resonance frequencies at which it is sensitive to axion-to-photon conversion. A realistic tuning mechanism requires a gap between the cavity end caps and the tuning rod to ensure movement, and causes some modes to hybridize with the resonant mode that is being tracked for the experiment. These so-called mode mixings lead to gaps in the frequency range that practically lose sensitivity to axions. In order to solve this problem, we present a cavity design which, for two tuning rod configurations corresponding to a lower and higher frequency range, have a dielectric rod inserted at a specific location that makes the cavity asymmetrical. Moving the tuning rod closer to the dielectric insert changes the location and frequency of the mode mixing compared to when it is farther away from it. This design is easily realizable in practical experiments and makes possible an axion dark matter search with minimal loss in sensitivity due to mode mixings. We also show that the same design has the same desired effect when cavity dimensions are scaled down to be smaller and are at higher resonance frequencies.

hep-ex

Maximizing Quantum Enhancement in Axion Dark Matter Experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon-counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1--30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies ($ν>$ 5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the over-coupling regime, up to $β\sim 10$; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

hep-ex

Extensive search for axion dark matter over 1\,GHz with CAPP's Main Axion eXperiment

We report an extensive high-sensitivity search for axion dark matter above 1\,GHz at the Center for Axion and Precision Physics Research (CAPP). The cavity resonant search, exploiting the coupling between axions and photons, explored the frequency (mass) range of 1.025\,GHz (4.24\,$μ$eV) to 1.185\,GHz (4.91\,$μ$eV). We have introduced a number of innovations in this field, demonstrating the practical approach of optimizing all the relevant parameters of axion haloscopes, extending presently available technology. The CAPP 12\,T magnet with an aperture of 320\,mm made of Nb$_3$Sn and NbTi superconductors surrounding a 37-liter ultralight-weight copper cavity is expected to convert DFSZ axions into approximately $10^2$ microwave photons per second. A powerful dilution refrigerator, capable of keeping the core system below 40\,mK, combined with quantum-noise limited readout electronics, achieved a total system noise of about 200\,mK or below, which corresponds to a background of roughly $4\times 10^3$ photons per second within the axion bandwidth. The combination of all those improvements provides unprecedented search performance, imposing the most stringent exclusion limits on axion--photon coupling in this frequency range to date. These results also suggest an experimental capability suitable for highly-sensitive searches for axion dark matter above 1\,GHz.

hep-ex

Search for the Sagittarius Tidal Stream of Axion Dark Matter around 4.55 $μ$eV

We report the first search for the Sagittarius tidal stream of axion dark matter around 4.55 $μ$eV using CAPP-12TB haloscope data acquired in March of 2022. Our result excluded the Sagittarius tidal stream of Dine-Fischler-Srednicki-Zhitnitskii and Kim-Shifman-Vainshtein-Zakharov axion dark matter densities of $ρ_a\gtrsim0.184$ and $\gtrsim0.025$ GeV/cm$^{3}$, respectively, over a mass range from 4.51 to 4.59 $μ$eV at a 90% confidence level.

hep-ex

Axion Dark Matter Search around 4.55 $μ$eV with Dine-Fischler-Srednicki-Zhitnitskii Sensitivity

We report an axion dark matter search at Dine-Fischler-Srednicki-Zhitnitskii sensitivity with the CAPP-12TB haloscope, assuming axions contribute 100\% of the local dark matter density. The search excluded the axion--photon coupling $g_{aγγ}$ down to about $6.2\times10^{-16}$ GeV$^{-1}$ over the axion mass range between 4.51 and 4.59 $μ$eV at a 90\% confidence level. The achieved experimental sensitivity can also exclude Kim-Shifman-Vainshtein-Zakharov axion dark matter that makes up just 13\% of the local dark matter density. The CAPP-12TB haloscope will continue the search over a wide range of axion masses.

hep-ex