SearcharxivSearch

arXiv subjects

Andrew Webb

Publications and source records attributed to Andrew Webb.

At least 19 recordsLinked to original sources

Conditional Flow Matching for Cross-Field MRI Harmonisation

Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data across sites. We address cross-field brain-MRI translation for the MRIxFields2026 challenge, and in particular its Task~3: a single model that translates between any directed pair of the five field strengths and across three contrasts. We phrase the problem as a conditional flow matching path: because the source and target volumes are spatially registered, we learn a velocity field that carries the source slice directly to the target slice, rather than starting from noise. To learn this mapping from only three paired subjects, the unified model is trained in three stages: a degradation-bridge pretraining that distills a restoration prior from the abundant unpaired retrospective cohort, a cross-field finetuning over all directed pairs on the paired cohort, and an adversarial refinement that sharpens the output. At inference, we integrate the learned velocity with a second-order Heun solver in a handful of steps. A restoration prior learned without any paired data already reaches a mean SSIM of 0.837, and each subsequent training stage improves on it. A single 6.3M-parameter model thereby covers all 60 field-pair and contrast combinations, with inference in five solver steps per slice. On the challenge evaluation set the model reaches a mean SSIM of 0.909, averaged over the three contrasts, outperforming regression and diffusion baselines built on the identical network on all three challenge metrics.

cs.CV

Deep Unrolled Networks in Representation Space Applied to MRI Reconstruction

Deep unrolled networks (DUNs) integrate physical forward models with learned regularization in cascaded network architectures, achieving exceptional performance in inverse problems while maintaining interpretability. While most DUNs operate in the object domain (e.g., image space), recent variants explored representation spaces for improved information flow. However, these methods rely on heuristic methods for data consistency (DC), sacrificing fidelity with measurements. In this work, we introduce DUNE (Deep Unrolled Networks in rEpresentation space), a framework that maintains exact adherence to physical measurements while operating in learned representation spaces. By deriving the DC gradient via the chain rule and implementing it through the Vector-Jacobian Product (VJP), we enable exact backpropagation of measurement residuals into the representation space. This formulation supports diverse architectural backbones, including pre-trained encoders to guide the iterative process. We assess DUNE against state-of-the-art baselines on accelerated MRI reconstruction tasks, demonstrating that exact VJP-based gradients yield superior reconstruction quality and structural fidelity across both single-channel portable low-field and multi-channel clinical high-field MRI acquisitions. The code will be available upon publication at https://github.com/EfeIlicak/DUNE.

eess.IV

Physics-Guided Dual-Domain Network with Attention-Based Fusion for Portable MRI Reconstruction

Portable low-field magnetic resonance imaging (MRI) systems have gained renewed interest owing to their cost effectiveness and point-of-care imaging capabilities. Yet, portable MRI systems suffer from relatively low signal-to-noise ratio and limited hardware capabilities. While previous works have proposed the use of deep learning based reconstruction methods to improve low-field image quality, these operated only in the image-domain. Unlike other imaging modalities, MRI directly acquires data in the Fourier-domain (k-space), and exploiting both k-space and image-domain information can improve reconstruction quality. Here, we introduce DUN-DD, a novel physics-guided 3D network for portable MRI reconstruction, with parallel dual-domain branches whose outputs are combined together via an attention-based fusion network. To demonstrate the performance of the proposed method, we present \textit{in vivo} reconstructions obtained from both emulated datasets as well as images acquired with a 47mT Halbach-based portable MRI system. Our results show that DUN-DD outperforms state-of-the-art classical, data-driven, and physics-guided methods on both emulated and real portable MRI acquisitions.

physics.med-ph

In-vivo imaging with a low-cost MRI scanner and cloud data processing in low-resource settings

Purpose: To demonstrate in-vivo imaging with a low-cost, low-field MRI scanner built and operated in Africa, and to show how systematic hardware and software improvements can mitigate the main operational limitations encountered in low-resource environments. Methods: A 46 mT Halbach scanner located at the Mbarara University of Science and Technology (Uganda) was upgraded through a complete reorganization of grounding and shielding, installation of new control electronics and open-source user-interface software. Noise performance was quantified using a standardized protocol and in-vivo brain images were acquired with three-dimensional RARE sequences. Distortion correction was implemented using cloud-based reconstructions incorporating magnetic field maps. Results: The revamped system reached noise levels routinely below three times the thermal limit and demonstrated stable operation over multi-day measurements. Three-dimensional T1- and T2-weighted brain images were successfully acquired and distortion-corrected with remote GPU-based reconstructions and near real-time visualization through the user interface. Conclusions: The results show that low-cost MRI systems can achieve clinically relevant image quality when electromagnetic noise and power-grid instabilities are properly addressed. This work highlights the feasibility of sustainable MRI development in low-resource settings and identifies stable power delivery and local capacity building as the key next steps toward clinical translation.

physics.med-ph

Physics-Informed Deep Unrolled Network for Portable MR Image Reconstruction

Magnetic resonance imaging (MRI) is the gold standard imaging modality for numerous diagnostic tasks, yet its usefulness is tempered due to its high cost and infrastructural requirements. Low-cost very-low-field portable scanners offer new opportunities, while enabling imaging outside conventional MRI suites. However, achieving diagnostic-quality images in clinically acceptable scan times remains challenging with these systems. Therefore methods for improving the image quality while reducing the scan duration are highly desirable. Here, we investigate a physics-informed 3D deep unrolled network for the reconstruction of portable MR acquisitions. Our approach includes a novel network architecture that utilizes momentum-based acceleration and leverages complex conjugate symmetry of k-space for improved reconstruction performance. Comprehensive evaluations on emulated datasets as well as 47mT portable MRI acquisitions demonstrate the improved reconstruction quality of the proposed method compared to existing methods.

physics.med-ph

Subject grounding to reduce electromagnetic interference for MRI scanners operating in unshielded environments

Purpose. Portable low-field (< 0.1 T) MRI is increasingly used for point-of-care imaging, but electromagnetic interference (EMI) presents a significant challenge, especially in unshielded environments. EMI can degrade image quality and compromise diagnostic utility. This study investigates whether subject grounding can effectively reduce EMI and improve image quality, comparing different grounding strategies. Methods. Experiments were conducted using a 47 mT Halbach-based MRI scanner with a single receive channel. Reproducibility was evaluated at a second site using a 72 mT scanner with similar geometry. Turbo spin echo sequences were used to image the hand and brain. Subject grounding was implemented using conductive cloth sleeves or ECG electrodes, each connected between the subject's skin and scanner ground. Three EMI conditions were tested: ambient, added single-frequency EMI, and broadband EMI. Signal-to-noise ratios (SNR) were calculated under each configuration. Results. Subject grounding significantly reduced EMI in both hand and brain scans. In hand imaging, conductive sleeves reduced noise from 85x to 1.25x the 50-ohm noise floor. In brain imaging, grounding alone reduced noise from 55x to 25x baseline; when combined with arc RF shields, noise was further reduced to 1.2x baseline, even under added EMI. These results were reproducible across different scanners and locations. Conclusion. Subject grounding is a simple, effective, and reproducible strategy for mitigating EMI in portable low-field MRI. It is especially effective for hand imaging, while brain imaging benefits from additional RF shielding. The approach is robust under various EMI conditions and may complement other denoising techniques.

physics.med-ph

Design and performance of a Toroidal RF Volume Coil with Intrinsic Electromagnetic Interference Rejection for low-field Portable Halbach-Based MRI Systems

Purpose: One of the intrinsic limitations of low-field MRI is low signal-to-noise ratio (SNR), which can be further reduced by electromagnetic interference (EMI) due to the lack of a Faraday shielded room. To address this issue, we propose a novel RF coil design that is inherently less sensitive to EMI while maintaining high receive sensitivity. Methods: The proposed coil structure is based on an anapole (toroidal) design and consists of six rings, each containing four continuous wires wound around an elliptical 3D-printed former. The wire in the entire structure is uninterrupted. This coil is designed for use in systems with an axial B0 field direction. The performance of the proposed RF coil was evaluated on a Halbach array system designed for neuroimaging and operating at 47mT and compared with a widely used spiral head coil. Results: The noise level achieved by the proposed toroidal coil in combination with a belt wrapped around the subjects and grounded to the scanner was comparable to that of the widely used spiral head coil when combined with a grounding belt and passive aluminum shielding. The coil transmit and receive efficiency was comparable to the efficiency of the spiral head coil. Conclusion: The proposed RF coil inherently reduces the effect of EMI, potentially removing or reducing the need for passive shielding or external/internal sensors for EMI reduction in post-processing.

physics.med-ph

An imageless magnetic resonance framework for fast and cost-effective decision-making

Magnetic Resonance Imaging (MRI) is the gold standard in countless diagnostic procedures, yet hardware complexity, long scans, and cost preclude rapid screening and point-of-care use. We introduce Imageless Magnetic Resonance Diagnosis (IMRD), a framework that bypasses k-space sampling and image reconstruction by analyzing raw one-dimensional MR signals. We identify potentially impactful embodiments where IMRD requires only optimized pulse sequences for time-domain contrast, minimal low-field hardware, and pattern recognition algorithms to answer clinical closed queries and quantify lesion burden. As a proof of concept, we simulate multiple sclerosis lesions in silico within brain phantoms and deploy two extremely fast protocols (approximately 3 s), with and without spatial information. A 1D convolutional neural network achieves AUC close to 0.95 for lesion detection and R2 close to 0.99 for volume estimation. We also perform robustness tests under reduced signal-to-noise ratio, partial signal omission, and relaxation-time variability. By reframing MR signals as direct diagnostic metrics, IMRD paves the way for fast, low-cost MR screening and monitoring in resource-limited environments.

physics.med-ph

Deep learning of personalized priors from past MRI scans enables fast, quality-enhanced point-of-care MRI with low-cost systems

Magnetic resonance imaging (MRI) offers superb-quality images, but its accessibility is limited by high costs, posing challenges for patients requiring longitudinal care. Low-field MRI provides affordable imaging with low-cost devices but is hindered by long scans and degraded image quality, including low signal-to-noise ratio (SNR) and tissue contrast. We propose a novel healthcare paradigm: using deep learning to extract personalized features from past standard high-field MRI scans and harnessing them to enable accelerated, enhanced-quality follow-up scans with low-cost systems. To overcome the SNR and contrast differences, we introduce ViT-Fuser, a feature-fusion vision transformer that learns features from past scans, e.g. those stored in standard DICOM CDs. We show that \textit{a single prior scan is sufficient}, and this scan can come from various MRI vendors, field strengths, and pulse sequences. Experiments with four datasets, including glioblastoma data, low-field ($50mT$), and ultra-low-field ($6.5mT$) data, demonstrate that ViT-Fuser outperforms state-of-the-art methods, providing enhanced-quality images from accelerated low-field scans, with robustness to out-of-distribution data. Our freely available framework thus enables rapid, diagnostic-quality, low-cost imaging for wide healthcare applications.

eess.IV

ezyMRI: How to build an MRI machine from scratch -- Experience from a four-day hackathon

Nuclear magnetic resonance instruments are becoming available to the do-it-yourself community. The challenges encountered in the endeavor to build a magnetic resonance imaging instrument from scratch were confronted in a four-day hackathon at Singapore University of Technology and Design in spring 2024. One day was devoted to educational lectures and three days to system construction and testing. Seventy young researchers from all parts of the world formed six teams focusing on magnet, gradient coil, RF coil, console, system integration, and design, which together produced a working MRI instrument in three days. The different steps, encountered challenges, and their solutions are reported.

physics.med-ph

Flexible metasurface for improving brain imaging at 7T

Ultra-high field MRI offers unprecedented detail for non-invasive visualization of the human brain. However, brain imaging is challenging at 7T due to the B$_1^+$ field inhomogeneity, which results in signal intensity drops in temporal lobes and a bright region in the brain center. This study aims to evaluate using a metasurface to improve brain imaging at 7T and simplify the investigative workflow. Two flexible metasurfaces, each comprising a periodic structure of copper strips and parallel-plate capacitive elements printed on an ultra-thin substrate, were optimized for brain imaging and implemented via PCB. We considered two setups: (1) two metasurfaces located near the temporal lobes; and (2) one metasurface placed near the occipital lobe The effect of metasurface placement on the transmit efficiency and specific absorption rate was evaluated via electromagnetic simulation studies with voxelized models. In addition, their impact on SNR and diagnostic image quality was evaluated in vivo for male and female volunteers. Placement of metasurfaces near the regions of interest led to an increase in homogeneity of the transmit field by 5$\%$ and 10.5$\%$ in the right temporal lobe and occipital lobe for a male subject, respectively. SAR values changed insignificantly and were under recommended limits. In vivo studies also confirmed the numerically predicted improvement in field distribution and receive sensitivity in the desired ROI. Optimized metasurfaces enable homogenizing transmit field distribution in the brain at 7T. The proposed lightweight and flexible structure has the potential to provide MR examination with higher diagnostic value images.

physics.med-ph

Twisted Pair Transmission Line Coil -- A Flexible, Self-Decoupled and Extremely Robust Element for 7T MRI

This study evaluates the performance of a twisted pair transmission line coil as a transceive element for 7T MRI in terms of physical flexibility, robustness to shape deformations, and interelement decoupling. Each coil element was created by shaping a twisted pair of wires into a circle. One wire was interrupted at the top, while the other was interrupted at the bottom, and connected to the matching circuit. Electromagnetic simulations were conducted to determine the optimal number of twists per length (in terms of B$_1^+$ field efficiency, SAR efficiency, sensitivity to elongation and interelement decoupling properties) and for investigating the fundamental operational principle of the coil through fields streamline visualization. A comparison between the twisted pair coil and a conventional loop coil in terms of B$_1^+$ fields, maxSAR10g, and stability of $S_{11}$ when the coil was deformed, was performed. Experimentally measured interelement coupling between individual elements of multichannel arrays was also investigated. Increasing the number of twists per length resulted in a more physically robust coil. Poynting vector streamline visualization showed that the twisted pair coil concentrated most of the energy in the near field. The twisted pair coil exhibited comparable B$_1^+$ fields and improved maxSAR10g to the conventional coil but demonstrated exceptional stability with respect to coil deformation and a strong self-decoupling nature when placed in an array configuration. The findings highlight the robustness of the twisted pair coil, showcasing its stability under shape variations. This coil holds great potential as a flexible RF coil for various imaging applications using multiple-element arrays, benefiting from its inherent decoupling.

physics.med-ph

A Unified Theory of Diversity in Ensemble Learning

We present a theory of ensemble diversity, explaining the nature of diversity for a wide range of supervised learning scenarios. This challenge has been referred to as the holy grail of ensemble learning, an open research issue for over 30 years. Our framework reveals that diversity is in fact a hidden dimension in the bias-variance decomposition of the ensemble loss. We prove a family of exact bias-variance-diversity decompositions, for a wide range of losses in both regression and classification, e.g., squared, cross-entropy, and Poisson losses. For losses where an additive bias-variance decomposition is not available (e.g., 0/1 loss) we present an alternative approach: quantifying the effects of diversity, which turn out to be dependent on the label distribution. Overall, we argue that diversity is a measure of model fit, in precisely the same sense as bias and variance, but accounting for statistical dependencies between ensemble members. Thus, we should not be maximising diversity as so many works aim to do -- instead, we have a bias/variance/diversity trade-off to manage.

cs.LG

MaRCoS, an open-source electronic control system for low-field MRI

Every magnetic resonance imaging (MRI) device requires an electronic control system that handles pulse sequences and signal detection and processing. Here we provide details on the architecture and performance of MaRCoS, a MAgnetic Resonance COntrol System developed by an open international community of low-field MRI researchers. MaRCoS is inexpensive and can handle cycle-accurate sequences without hard length limitations, rapid bursts of events, and arbitrary waveforms. It can also be easily adapted to meet further specifications required by the various academic and private institutions participating in its development. We describe the MaRCoS hardware, firmware and software that enable all of the above, including a Python-based graphical user interface for pulse sequence implementation, data processing and image reconstruction.

physics.med-ph

HAWKS: Evolving Challenging Benchmark Sets for Cluster Analysis

Comprehensive benchmarking of clustering algorithms is rendered difficult by two key factors: (i)~the elusiveness of a unique mathematical definition of this unsupervised learning approach and (ii)~dependencies between the generating models or clustering criteria adopted by some clustering algorithms and indices for internal cluster validation. Consequently, there is no consensus regarding the best practice for rigorous benchmarking, and whether this is possible at all outside the context of a given application. Here, we argue that synthetic datasets must continue to play an important role in the evaluation of clustering algorithms, but that this necessitates constructing benchmarks that appropriately cover the diverse set of properties that impact clustering algorithm performance. Through our framework, HAWKS, we demonstrate the important role evolutionary algorithms play to support flexible generation of such benchmarks, allowing simple modification and extension. We illustrate two possible uses of our framework: (i)~the evolution of benchmark data consistent with a set of hand-derived properties and (ii)~the generation of datasets that tease out performance differences between a given pair of algorithms. Our work has implications for the design of clustering benchmarks that sufficiently challenge a broad range of algorithms, and for furthering insight into the strengths and weaknesses of specific approaches.

cs.NE

Gradient Coil Design and Realization for a Halbach-Based MRI System

In this paper we design and construct gradient coils for a Halbach permanent magnet array magnetic resonance (MR) scanner. The target field method, which is widely applied for the case of axial static magnetic fields, has been developed for a transverse static magnetic field as produced by a Halbach permanent magnet array. Using this method, current densities for three gradient directions are obtained and subsequently verified using a commercial magneto-static solver. Stream functions are used to turn the surface current densities into wire patterns for constructing the gradient coils. The measured fields are in good agreement with simulations and their prescribed target fields. Three dimensional images have been acquired using the constructed gradient coils with very low degree of geometric distortion.

physics.med-ph

Hierarchical stochastic neighbor embedding as a tool for visualizing the encoding capability of magnetic resonance fingerprinting dictionaries

In Magnetic Resonance Fingerprinting (MRF) the quality of the estimated parameter maps depends on the encoding capability of the variable flip angle train. In this work we show how the dimensionality reduction technique Hierarchical Stochastic Neighbor Embedding (HSNE) can be used to obtain insight into the encoding capability of different MRF sequences. Embedding high-dimensional MRF dictionaries into a lower-dimensional space and visualizing them with colors, being a surrogate for location in low-dimensional space, provides a comprehensive overview of particular dictionaries and, in addition, enables comparison of different sequences. Dictionaries for various sequences and sequence lengths were compared to each other, and the effect of transmit field variations on the encoding capability was assessed. Clear differences in encoding capability were observed between different sequences, and HSNE results accurately reflect those obtained from an MRF matching simulation.

eess.IV

The environment of HI-bearing ultra diffuse galaxies in the ALFALFA survey

We explore the environment of 252 HI-bearing Ultra Diffuse Galaxies (HUDs) from the 100% ALFALFA survey catalog in an attempt to constrain their formation mechanism. We select sources from ALFALFA with surface brightnesses, magnitudes, and radii consistent with other samples of Ultra Diffuse Galaxies (UDGs), without restrictions on their isolation or environment, more than doubling the previously reported ALFALFA sample. We quantify the galactic environment of HUDs using several metrics, including n-th nearest neighbour, tidal influence, membership in a group/cluster, and distance from nearest group/cluster or filament. We find that that HUDs inhabit the same environments as other samples of HI-selected galaxies and that they show no environmental preference in any metric. We suggest that these results are consistent with a picture of the extreme properties of HUDs being driven by internal mechanisms and that they are largely unperturbed by environmental impacts. While environmental effects may be necessary to convert HUDs into gas-poor cluster UDGs, these effects are not required for diffuse galaxies to exist in the first place.

astro-ph.GA