Searcharxiv⌕ Search

arXiv subjects

Andy Zhou

Publications and source records attributed to Andy Zhou.

24 records · Page 2Linked to original sources

A Sentence Speaks a Thousand Images: Domain Generalization through Distilling CLIP with Language Guidance

Domain generalization studies the problem of training a model with samples from several domains (or distributions) and then testing the model with samples from a new, unseen domain. In this paper, we propose a novel approach for domain generalization that leverages recent advances in large vision-language models, specifically a CLIP teacher model, to train a smaller model that generalizes to unseen domains. The key technical contribution is a new type of regularization that requires the student's learned image representations to be close to the teacher's learned text representations obtained from encoding the corresponding text descriptions of images. We introduce two designs of the loss function, absolute and relative distance, which provide specific guidance on how the training process of the student model should be regularized. We evaluate our proposed method, dubbed RISE (Regularized Invariance with Semantic Embeddings), on various benchmark datasets and show that it outperforms several state-of-the-art domain generalization methods. To our knowledge, our work is the first to leverage knowledge distillation using a large vision-language model for domain generalization. By incorporating text-based information, RISE improves the generalization capability of machine learning models.

cs.CV↗

Memory-Efficient, Limb Position-Aware Hand Gesture Recognition using Hyperdimensional Computing

Electromyogram (EMG) pattern recognition can be used to classify hand gestures and movements for human-machine interface and prosthetics applications, but it often faces reliability issues resulting from limb position change. One method to address this is dual-stage classification, in which the limb position is first determined using additional sensors to select between multiple position-specific gesture classifiers. While improving performance, this also increases model complexity and memory footprint, making a dual-stage classifier difficult to implement in a wearable device with limited resources. In this paper, we present sensor fusion of accelerometer and EMG signals using a hyperdimensional computing model to emulate dual-stage classification in a memory-efficient way. We demonstrate two methods of encoding accelerometer features to act as keys for retrieval of position-specific parameters from multiple models stored in superposition. Through validation on a dataset of 13 gestures in 8 limb positions, we obtain a classification accuracy of up to 93.34%, an improvement of 17.79% over using a model trained solely on EMG. We achieve this while only marginally increasing memory footprint over a single limb position model, requiring $8\times$ less memory than a traditional dual-stage classification architecture.

cs.LG↗

Wireless User-Generic Ear EEG

In the past few years it has been demonstrated that electroencephalography (EEG) can be recorded from inside the ear (in-ear EEG). To open the door to low-profile earpieces as wearable brain-computer interfaces (BCIs), this work presents a practical in-ear EEG device based on multiple dry electrodes, a user-generic design, and a lightweight wireless interface for streaming data and device programming. The earpiece is designed for improved ear canal contact across a wide population of users and is fabricated in a low-cost and scalable manufacturing process based on standard techniques such as vacuum forming,plasma-treatment, and spray coating. A 2.5x2.5 cm^2 wireless recording module is designed to record and stream data wirelessly to a host computer. Performance was evaluated on three human subjects over three months and compared with clinical-grade wet scalp EEG recordings. Recordings of spontaneous and evoked physiological signals, eye-blinks, alpha rhythm, and the auditory steady-state response (ASSR), are presented. This is the first wireless in-ear EEG to our knowledge to incorporate a dry multielectrode, user-generic design. The user-generic ear EEG recorded a mean alpha modulation of 2.17, outperforming the state-of-the-art in dry electrode in-ear EEG systems.

q-bio.QM↗

Analysis of Contraction Effort Level in EMG-Based Gesture Recognition Using Hyperdimensional Computing

Varying contraction levels of muscles is a big challenge in electromyography-based gesture recognition. Some use cases require the classifier to be robust against varying force changes, while others demand to distinguish between different effort levels of performing the same gesture. We use brain-inspired hyperdimensional computing paradigm to build classification models that are both robust to these variations and able to recognize multiple contraction levels. Experimental results on 5 subjects performing 9 gestures with 3 effort levels show up to 39.17% accuracy drop when training and testing across different effort levels, with up to 30.35% recovery after applying our algorithm.

cs.HC↗

WAND: A 128-channel, closed-loop, wireless artifact-free neuromodulation device

Closed-loop neuromodulation systems aim to treat a variety of neurological conditions by dynamically delivering and adjusting therapeutic electrical stimulation in response to a patient's neural state, recorded in real-time. Existing systems are limited by low channel counts, lack of algorithmic flexibility, and distortion of recorded signals from large, persistent stimulation artifacts. Here, we describe a device that enables new research applications requiring high-throughput data streaming, low-latency biosignal processing, and truly simultaneous sensing and stimulation. The Wireless Artifact-free Neuromodulation Device (WAND) is a miniaturized, wireless neural interface capable of recording and stimulating on 128 channels with on-board processing to fully cancel stimulation artifacts, detect neural biomarkers, and automatically adjust stimulation parameters in a closed-loop fashion. It combines custom application specific integrated circuits (ASICs), an on-board FPGA, and a low-power bidirectional radio. We validate wireless, long-term recordings of local field potentials (LFP) and real-time cancellation of stimulation artifacts in a behaving nonhuman primate (NHP). We use WAND to demonstrate a closed-loop stimulation paradigm to disrupt movement preparatory activity during a delayed-reach task in a NHP in vivo. This wireless device, leveraging custom ASICs for both neural recording and electrical stimulation modalities, makes possible a neural interface platform technology to significantly advance both neuroscientific discovery and preclinical investigations of stimulation-based therapeutic interventions.

q-bio.NC↗

An EMG Gesture Recognition System with Flexible High-Density Sensors and Brain-Inspired High-Dimensional Classifier

EMG-based gesture recognition shows promise for human-machine interaction. Systems are often afflicted by signal and electrode variability which degrades performance over time. We present an end-to-end system combating this variability using a large-area, high-density sensor array and a robust classification algorithm. EMG electrodes are fabricated on a flexible substrate and interfaced to a custom wireless device for 64-channel signal acquisition and streaming. We use brain-inspired high-dimensional (HD) computing for processing EMG features in one-shot learning. The HD algorithm is tolerant to noise and electrode misplacement and can quickly learn from few gestures without gradient descent or back-propagation. We achieve an average classification accuracy of 96.64% for five gestures, with only 7% degradation when training and testing across different days. Our system maintains this accuracy when trained with only three trials of gestures; it also demonstrates comparable accuracy with the state-of-the-art when trained with one trial.

cs.HC↗