Radial distribution gain at 633 nm in a He-Ne RF-excited small bore discharge

Devices as Large Ring Laser Gyroscopes (RLG) for fundamental physics and geophysics investigation are currently run by means of RF power supply systems. This is not the standard method to supply a gas laser, that typically is powered with a DC system. In literature RF power supply lasers have been studied several years ago, and to correctly understand the behaviour of devices as RLG a more detailed study has been pursued. Detailed study of the radial distribution of the optical gain of an He-Ne discharge cell in function of gas pressure and RF power supply will be illustrated, discussed and compared with existing literature. The presented analysis demonstrates that it is possible to optimize the RLG operation with a proper choice of gas pressure and power level of the RF power supply. Accordingly we have been able to establish transversal and longitudinal single-mode operation our prototype GP2.

physics.optics↗

Testing general relativity by means of ringlasers

The paper discusses the optimal conguration of one or more ring lasers to be used for measuring the general relativistic effects of the rotation of the earth, as manifested on the surface of the planet. The analysis is focused on devices having their normal vector lying in the meridian plane. The crucial role of the evaluation of the angles is evidenced. Special attention is paid to the orientation at the maximum signal, minimizing the sensitivity to the orientation uncertainty. The use of rings at different latitudes is mentioned and the problem of the non-sfericity of the earth is commented.

gr-qc↗

First Results of GINGERino, a deep underground ringlaser

Large ring-laser gyroscopes are capable of measuring angular rotations with a precision well below fractions of $prad/s$, not far from $10^{-14}$ $rad/s$, the accuracy required for General Relativity tests, this is what the GINGER (Gyroscope-IN-GEneral-Relativity) experiment is aiming for. These features do not guarantee the possibility of measuring the General Relativity Lense--Thirring effect, that manifests itself as a tiny ($\approx 10^{-9} \times Ω_E$) perturbation of the Earth rotation rate. An underground location being in principle less affected by external local disturbances represents a good candidate for housing such a challenging experiment. GINGERino is a test apparatus to investigate the residual local disturbances in the most inner part of the underground international laboratory of the GranSasso (LNGS). It consists of a square ring laser with a $3.6$ m side. The instrument has been tailored to be the larger allowed by the particular location inside the laboratory. Its main objective is to measure the very low frequency rotational motions, in order to prove that LNGS is a suitable location for very low noise measurements and, possibly, General Relativity tests. Aside this main goal, GINGERino will provide unique data for geodesy and geophysics. Its installation has been completed during 2015. Since then, several long set of data have been collected, and the apparatus has been continuously running unattended for more than one week. The typical power spectrum sensitivity was a few $ 10^{-10} rad/s/\sqrt(Hz)$, with integration time not longer than tens of seconds. Improvements of the apparatus are ongoing in order to improve the integration time.

physics.ins-det↗

First deep underground observation of rotational signals from an earthquake at teleseismic distance using a large ring laser gyroscope

Recent advances in large ring laser gyroscopes (RLG) technologies opened the possibility to observe rotations of the ground with sensitivities up to $10^{-11}$ $\frac{rad}{s}$ over the frequency band of seismological interest (0.01-1Hz), thus opening the way to a new geophysical discipline, i.e. rotational seismology. A measure of rotations in seismology is of fundamental interest for (a) the determination of all the six degrees of freedom that characterize a rigid body motion, and (b) the quantitative estimate of the rotational motions contaminating ground translation measurements obtained from standard seismometers. Within this framework, this paper presents and describes GINGERino, a new large observatory-class RLG located in Gran Sasso underground laboratory (LNGS), one national laboratories of the INFN (Istituto Nazionale di Fisica Nucleare). We also report unprecedented observations and analyses of the roto-translational signals from a tele-seismic event observed in such a deep underground environment.

physics.geo-ph↗

Controlling the nonlinear intracavity dynamics of large He-Ne laser gyroscopes

A model based on Lamb's theory of gas lasers is applied to a He-Ne ring laser gyroscope in order to estimate and remove the laser dynamics contribution from the rotation measurements. The intensities of the counter-propagating laser beams exiting one cavity mirror are continuously observed together with a monitor of the laser population inversion. These observables, once properly calibrated with a dedicated procedure, allow us to estimate cold cavity and active medium parameters driving the main part of the nonlinearities of the system. The parameters identification and noise subtraction procedure has been verified by means of a Monte Carlo study of the system, and experimentally tested on the G-Pisa ring laser oriented with the normal to the ring plane almost parallel to the Earth rotation axis. In this configuration the Earth rotation-rate provides the maximum Sagnac effect while the contribution of the orientation error is reduced at minimum. After the subtraction of laser dynamics by a Kalman filter, the relative systematic errors of G-PISA reduce from 50 to 5 part in 10^3 and can be attributed to the residual uncertainties on geometrical scale factor and orientation of the ring.

physics.optics↗

Compensation of the laser parameters fluctuations in large ring laser gyros: a Kalman filter approach

He-Ne ring laser gyroscopes are, at present, the most precise devices for absolute angular velocity measurements. Limitations to their performance come from the non--linear dynamics of the laser. Following the Lamb semi-classical theory, we find a set of critical parameters affecting the time stability of the system. We propose a method for estimating the long term drift of the laser parameters and for filtering out the laser dynamics effects from the rotation measurement. The parameter estimation procedure, based on the perturbative solutions of the laser dynamics, allow us to apply Kalman Filter theory for the estimation of the angular velocity. Results of a comprehensive Monte Carlo simulation and results of a preliminary analysis on experimental data from the ring laser prototype G-Pisa are shown and discussed.

physics.ins-det↗

Measuring the Virgo area tilt noise with a laser gyroscope

We report on the measurements of tilt noise performed at the Virgo site with a ring laser gyroscope. The apparatus is a He-Ne laser operating in a square cavity mounted on a vertical plane perpendicular to the north-south arm of the inteferometer. We discuss the possibility of using the ring laser signal to improve the performances of the control system of the Virgo seismic suspensions. The comparison between the ring laser signal and the control signals for the longitudinal translations of the inverted pendulum (IP) shows remarkable coherence in the frequency range 20-200 mHz.

physics.ins-det↗

A 1.82 m^2 ring laser gyroscope for nano-rotational motion sensing

We present a fully active-controlled He-Ne ring laser gyroscope, operating in square cavity 1.35 m in side. The apparatus is designed to provide a very low mechanical and thermal drift of the ring cavity geometry and is conceived to be operative in two different orientations of the laser plane, in order to detect rotations around the vertical or the horizontal direction. Since June 2010 the system is active inside the Virgo interferometer central area with the aim of performing high sensitivity measurements of environmental rotational noise. So far, continuous not attempted operation of the gyroscope has been longer than 30 days. The main characteristics of the laser, the active remote-controlled stabilization systems and the data acquisition techniques are presented. An off-line data processing, supported by a simple model of the sensor, is shown to improve the effective long term stability. A rotational sensitivity at the level of ten nanoradiants per squareroot of Hz below 1 Hz, very close to the required specification for the improvement of the Virgo suspension control system, is demonstrated for the configuration where the laser plane is horizontal.

physics.ins-det↗

Rotational sensitivity of the "G-Pisa" gyrolaser

G-Pisa is an experiment investigating the possibility to operate a high sensitivity laser gyroscope with area less than $1 \rm m^2$ for improving the performances of the mirrors suspensions of the gravitational wave antenna Virgo. The experimental set-up consists in a He-Ne ring laser with a 4 mirrors square cavity. The laser is pumped by an RF discharge where the RF oscillator includes the laser plasma in order to reach a better stability. The contrast of the Sagnac fringes is typically above 50% and a stable regime has been reached with the laser operating both single mode or multimode. The effect of hydrogen contamination on the laser was also checked. A low-frequency sensitivity, below $1 \rm Hz$, in the range of $10^{-8} \rm {(rad / s)/ \sqrt{Hz}}$ has been measured.

physics.optics↗

Prospects for Stochastic Background Searches Using Virgo and LSC Interferometers

We consider the question of cross-correlation measurements using Virgo and the LSC Interferometers (LIGO Livingston, LIGO Hanford, and GEO600) to search for a stochastic gravitational-wave background. We find that inclusion of Virgo into the network will substantially improve the sensitivity to correlations above 200 Hz if all detectors are operating at their design sensitivity. This is illustrated using a simulated isotropic stochastic background signal, generated with an astrophysically-motivated spectrum, injected into 24 hours of simulated noise for the LIGO and Virgo interferometers.