SearcharxivSearch

arXiv subjects

Anna Schweingruber

Publications and source records attributed to Anna Schweingruber.

3 recordsLinked to original sources

Fast, low noise, megapixel detector and readout systems for future X-ray astronomy missions

Next-generation strategic X-ray astronomy missions will require the simultaneous achievement of high angular resolution, large effective collecting area, and wide-field imaging with large-format focal plane detectors. Realizing the associated science objectives--ranging from precision measurements of bright point sources to the detection and characterization of faint diffuse emission-places stringent and, in some cases, competing requirements on detector performance. In particular, high frame rates are necessary to mitigate photon pile-up in observations of bright sources and to reduce contamination from particle-induced background in measurements of low surface brightness structures. At the same time, these instruments must preserve excellent soft X-ray response, which places tight constraints on read noise and on the fidelity of event characterization. State-of-the-art X-ray charge-coupled devices (CCDs) approach many of the key performance metrics required for these missions, but readout speed remains a primary limitation. Addressing this gap requires readout architectures that scale to high channel count, sustain high pixel throughput, and preserve the low-noise characteristics needed for soft X-ray sensitivity.

astro-ph.IM

Characterisation of the NewAthena WFI's DEPFET Flight Production's Operational Parameters

NewAthena's Wide Field Imager (WFI) uses detectors made up from Depleted P-Channel Field Effect Transistor (DEPFET) pixels operated in rolling shutter mode. The Large Detector Array (LDA) contains a 2 $\times$ 2 array of 512 $\times$ 512 pixels Large Detectors (LDs) allowing for a field of view of 40' $\times$ 40' with a frame time of 2 ms while the 64 $\times$ 64 pixels Fast Detector (FD) can observe very bright X-ray sources due to a faster frame time of 0.08 ms. Prototype sensors (64 $\times$ 64 pixels) were used to analyse the sensor's operational range and to optimise the ASIC and DEPFET parameters i.e. current and voltage settings, as well as the DEPFET read-out timing parameters, resulting in an improved energy resolution, reduced noise and otherwise improved sensor characteristics.

astro-ph.IM

Spectroscopic Performance of Detectors for Athena's WFI: Measurements and Simulation

The depleted p-channel field effect transistor is the chosen sensor type for the Wide Field Imager of the Athena mission. It will be used in two types of cameras. One will enable observations of a field of view of 40' x 40' by using an array of four 512 x 512 pixel sensors in a 2 x 2 configuration. A second, small one is designed to investigate bright, point-like sources with a time resolution of up to 40 microseconds. Sensors of final size, layout, and technology were fabricated, assembled and characterised. Also, first results from the flight production are available and confirm the excellent performance. In order to be able to estimate the future performance of degraded detectors, a simulation was developed that takes into account the non-analytical threshold effects on the basis of measurement results. We present the measurement analysis and the comparison of simulated and measured values as well as first attempts to use the Monte Carlo simulation to predict performance results based on noise measurements.

astro-ph.IM