Prompt Gamma Timing for range verification with carbon ion irradiation: first experimental measurements and comparison with Geant4 Monte Carlo simulations

Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays emitted by nuclear interactions. PGT distribution is highly sensitive to beam energy and target density, which, under controlled detector positioning, enables real-time monitoring of particle range, detection of morphological changes, and support for adaptive treatment strategies. This study investigates for the first time the application of PGT in carbon ion therapy. Measurements were performed using a dedicated detection system composed of a silicon strip sensor for primary ion timing and a LaBr3(Ce) read out by a SiPM for secondary radiation. Carbon ion beams with energies of 166.41, 268.86, and 398.84 MeV/u irradiated a homogeneous 30.0 cm PMMA target at CNAO. The secondary radiation detector was positioned at four off-beam positions to assess the robustness of the PGT technique. Simulations based on Geant4 were conducted for all configurations to evaluate agreement and predictive capability. A bin-by-bin comparison of experimental and simulated PGT intensities demonstrated strong agreement within the 95% confidence interval, with no incompatible bins at 166.41 MeV/u, at most 1% at 268.86 MeV/u, and up to 8% at 398.84 MeV/u, depending on detector position. Photons were identified as the dominant contribution to the detected signals, particularly for detector positions upstream with respect to the primary particle beam, minimizing signal contamination from neutrons and charged fragments. The validated experimental-simulation framework confirms the capability of the proposed PGT system to resolve energy-dependent differences and highlights its potential for detecting clinically relevant changes in the particle beam range, supporting further development toward real-time monitoring in carbon ion therapy.

physics.med-ph

Stopping power monitoring during proton therapy by means of prompt gamma timing: first experimental results with a homogeneous phantom

Proton therapy's full potential is limited by uncertainties that prevent optimal dose distribution. Monitoring techniques can reduce these uncertainties and enable adaptive treatment planning. Spatiotemporal Emission Reconstruction from Prompt-Gamma Timing (SER-PGT) is a promising method that provides insights into both particle range and stopping power, whose calculation would normally require knowledge about patient tissue properties that cannot be directly measured. We present the first experimental results using a 226.9 MeV synchrotron-proton beam impinging on a homogeneous phantom at a sub-clinical intensity (2 - 4 x 10^7 pps). SER-PGT uses data from a multi-detector setup: a thin and segmented Low Gain Avalanche Diode for proton detection and Lanthanum Bromide-based crystals for photon detection. The estimated stopping power profile showed an 8% +- 3% average error compared to NIST PSTAR values, and 2% +- 2% deviation relative to water at 100 MeV. Range assessment in a phantom with a 4 cm air-gap successfully identified the range shift with a 3 mm standard deviation. These results demonstrate the feasibility of using SER-PGT to recover both range and stopping power information through particle kinematics and PGT measurements.

physics.med-ph

Characterization of a modified clinical linear accelerator for ultra-high dose rate electron beam delivery

Irradiations at Ultra High Dose Rate (UHDR) regimes, exceeding 40 Gy/s in single fractions lasting less than 200 ms, have shown an equivalent antitumor effect compared to conventional radio-therapy with reduced harm to normal tissues. This work details the hardware and software modi-fications implemented to deliver 10 MeV UHDR electron beams with a Linear Accelerator Elekta SL 18 MV and the beam characteristics obtained. GafChromic EBT XD films and an Advanced Markus chamber were used for the dosimetry characterization, while a silicon sensor assessed the machine's beam pulses stability and repeatability. Dose per pulse, average dose rate and instantaneous dose rate in the pulse were evaluated for four experimental settings, varying the source-to-surface dis-tance and the beam collimation, i.e. with and without the use of a cylindrical applicator. Results showed dose per pulse from 0.6 Gy to a few tens of Gy and average dose rate up to 300 Gy/s. The obtained results demonstrate the possibility to perform in-vitro radiobiology experiments and test of new technologies for beam monitoring and dosimetry at the upgraded LINAC, thus contributing to the electron UHDR research field.

physics.med-ph