SearcharxivSearch

arXiv subjects

Annika Behrens

Publications and source records attributed to Annika Behrens.

3 recordsLinked to original sources

Radiation effects and noise evolution in NewAthena WFI flight-production sensors

The Wide Field Imager (WFI), one of the two instruments on ESA's next large X-ray observatory NewAthena, is designed for imaging spectroscopy in the 0.2-15 keV range, combining a large field of view with high count-rate capability. Its focal plane is equipped with back-illuminated DEPFET (Depleted p-channel field-effect transistor) sensors that offer high radiation tolerance and provide near Fano-limited energy resolution. Achieving this performance requires an exceptionally low readout noise, with about 3 electrons ENC expected at beginning of life. Consequently, the devices are highly sensitive to radiation-induced changes in noise behavior. In this work, we investigate the impact of both total non-ionizing dose (TNID) and total ionizing dose (TID) on the relevant noise components, including their temperature dependence. A detector module containing a 64x64-pixel sensor from a flight-production wafer was irradiated with 62.4 MeV protons at the MedAustron accelerator facility in Wiener Neustadt to a total dose equivalent to 2.6 $\cdot$ 10$^9$ 10-MeV-protons/cm$^2$. The detector was fully biased and operated throughout the irradiation and subsequent measurements, maintaining the nominal operating temperature of 213 K. To study short-term annealing behavior at low temperature, a second, identical module was exposed to a comparable proton dose within a much shorter timescale by exploiting the available high beam flux. TID effects were investigated separately by irradiating another device with 17.4 keV Mo-K_alpha X-rays to a total dose of 15 Gy. We report the resulting changes in readout noise, dark current, and threshold voltage, and compare them with results from an earlier irradiation campaign using pre-flight sensors. Implications for the instrument's required operating temperature and its expected end-of-life performance are discussed.

astro-ph.IM

Characterisation of the NewAthena WFI's DEPFET Flight Production's Operational Parameters

NewAthena's Wide Field Imager (WFI) uses detectors made up from Depleted P-Channel Field Effect Transistor (DEPFET) pixels operated in rolling shutter mode. The Large Detector Array (LDA) contains a 2 $\times$ 2 array of 512 $\times$ 512 pixels Large Detectors (LDs) allowing for a field of view of 40' $\times$ 40' with a frame time of 2 ms while the 64 $\times$ 64 pixels Fast Detector (FD) can observe very bright X-ray sources due to a faster frame time of 0.08 ms. Prototype sensors (64 $\times$ 64 pixels) were used to analyse the sensor's operational range and to optimise the ASIC and DEPFET parameters i.e. current and voltage settings, as well as the DEPFET read-out timing parameters, resulting in an improved energy resolution, reduced noise and otherwise improved sensor characteristics.

astro-ph.IM

Performance of the Hamamatsu R11410 Photomultiplier Tube in cryogenic Xenon Environments

The Hamamatsu R11410 photomultiplier, a tube of 3" diameter and with a very low intrinsic radioactivity, is an interesting light sensor candidate for future experiments using liquid xenon (LXe) as target for direct dark matter searches. We have performed several experiments with the R11410 with the goal of testing its performance in environments similar to a dark matter detector setup. In particular, we examined its long-term behavior and stability in LXe and its response in various electric field configurations.

astro-ph.IM