SearcharxivSearch

arXiv subjects

Anthony Fleury

Publications and source records attributed to Anthony Fleury.

8 recordsLinked to original sources

DAStatFormer: A Hybrid Multibranch Transformer with Statistical Feature Integration for DAS-Based Pattern Recognitions

Distributed Acoustic Sensing (DAS) enables large-scale monitoring through optical fibers, but its high dimensionality and complex spatio-temporal patterns make event classification demanding. Existing deep learning approaches-CNNs, recurrent models, and Transformer variants-either fail to capture long-range dependencies or require processing raw DAS matrices at prohibitive cost. We propose DAStatFormer, a hybrid multibranch Transformer that combines compact multidomain statistical features with Gated Transformer Networks. Instead of raw signals, we extract 24 ANOVA-selected attributes per channel from the temporal, waveform, and spectral domains, reducing data size by orders of magnitude while preserving discriminative information. Each domain is processed via dedicated step-wise and channel-wise attention branches, fused by an adaptive gating mechanism. Experiments on the open $\Phi$-OTDR benchmark and a real-scenario DAS dataset show that DAS-tatFormer achieves up to 99.4% accuracy and near-perfect real-world performance, while using significantly fewer parameters and lower inference cost than models such as DASFormer and DeepViT. These results demonstrate its suitability for scalable, real-time DAS-based monitoring. We release our code at https://github.com/MichelD-git/DAStatFormer

cs.LG

Can a Plantar Pressure-Based Tongue-Placed Electrotactile Biofeedback Improve Postural Control Under Altered Vestibular and Neck Proprioceptive Conditions?

We investigated the effects of a plantar pressure-based tongue-placed electrotactile biofeedback on postural control during quiet standing under normal and altered vestibular and neck proprioceptive conditions. To achieve this goal, fourteen young healthy adults were asked to stand upright as immobile as possible with their eyes closed in two Neutral and Extended head postures and two conditions of No-biofeedback and Biofeedback. The underlying principle of the biofeedback consisted of providing supplementary information related to foot sole pressure distribution through a wireless embedded tongue-placed tactile output device. Centre of foot pressure (CoP) displacements were recorded using a plantar pressure data acquisition system. Results showed that (1) the Extended head posture yielded increased CoP displacements relative to the Neutral head posture in the No-biofeedback condition, with a greater effect along the anteroposterior than mediolateral axis, whereas (2) no significant difference between the two Neutral and Extended head postures was observed in the Biofeedback condition. The present findings suggested that the availability of the plantar pressure-based tongue-placed electrotactile biofeedback allowed the subjects to suppress the destabilizing effect induced by the disruption of vestibular and neck proprioceptive inputs associated with the head extended posture. These results are discussed according to the sensory re-weighting hypothesis, whereby the central nervous system would dynamically and selectively adjust the relative contributions of sensory inputs (i.e., the sensory weights) to maintain upright stance depending on the sensory contexts and the neuromuscular constraints acting on the subject.

q-bio.NC

Postural destabilization induced by trunk extensor muscles fatigue is suppressed by use of a plantar pressure-based electro-tactile biofeedback

Separate studies have reported that postural control during quiet standing could be (1) impaired with muscle fatigue localized at the lower back, and (2) improved through the use of plantar pressure-based electro-tactile biofeedback, under normal neuromuscular state. The aim of this experiment was to investigate whether this biofeedback could reduce postural destabilization induced by trunk extensor muscles. Ten healthy adults were asked to stand as immobile as possible in four experimental conditions: (1) no fatigue/no biofeedback, (2) no fatigue/biofeedback, (3) fatigue/no biofeedback and (4) fatigue/biofeedback. Muscular fatigue was achieved by performing trunk repetitive extensions until maximal exhaustion. The underlying principle of the biofeedback consisted of providing supplementary information related to foot sole pressure distribution through electro-tactile stimulation of the tongue. Centre of foot pressure (CoP) displacements were recorded using a force platform. Results showed (1) increased CoP displacements along the antero-posterior axis in the fatigue than no fatigue condition in the absence of biofeedback and (2) no significant difference between the no fatigue and fatigue conditions in the presence of biofeedback. This suggests that subjects were able to efficiently integrate an artificial plantar pressure information delivered through electro-tactile stimulation of the tongue that allowed them to suppress the destabilizing effect induced by trunk extensor muscles fatigue.

q-bio.NC

A Wireless Embedded Tongue Tactile Biofeedback System for Balance Control

We describe the architecture of an original biofeedback system for balance improvement for fall prevention and present results of a feasibility study. The underlying principle of this biofeedback consists of providing supplementary information related to foot sole pressure distribution through a wireless embedded tongue-placed tactile output device. Twelve young healthy adults voluntarily participated in this experiment. They were asked to stand as immobile as possible with their eyes closed in two conditions of nobiofeedback and biofeedback. Centre of foot pressure (CoP) displacements were recorded using a force platform. Results showed reduced CoP displacements in the biofeedback relative to the no-biofeedback condition. On the whole, the present findings evidence the effectiveness of this system in improving postural control on young healthy adults. Further investigations are needed to strengthen the potential clinical value of this device.

q-bio.NC

Suppléance perceptive par électro-stimulation linguale embarquée : perspectives pour la prévention des escarres chez le blessé médullaire

We introduce the innovative technologies, based on the concept of "sensory substitution", we are developing in the fields of biomedical engineering and human disability. Precisely, our goal is to design, develop and validate practical assistive biomedical and/or technical devices and/or rehabilitating procedures for persons with disabilities, using artificial tongue-placed tactile biofeedback systems. This paper proposes an application for pressure sores prevention in case of spinal cord injuries (persons with paraplegia, or tetraplegia).

physics.med-ph

Pressure sensor-based tongue-placed electrotactile biofeedback for balance improvement - Biomedical application to prevent pressure sores formation and falls

We introduce the innovative technologies, based on the concept of "sensory substitution", we are developing in the fields of biomedical engineering and human disability. Precisely, our goal is to design, develop and validate practical assistive biomedical and/or technical devices and/or rehabilitating procedures for persons with disabilities, using artificial tongue-placed tactile biofeedback systems. Proposed applications are dealing with: (1) pressure sores prevention in case of spinal cord injuries (persons with paraplegia, or tetraplegia); and (2) balance control improvement to prevent fall in older and/or disabled adults. This paper describes the architecture and the functioning principle of these biofeedback systems and presents preliminary results of two feasibility studies performed on young healthy adults.

physics.med-ph

A Plantar-pressure Based Tongue-placed Tactile Biofeedback System for Balance Improvement

Maintaining an upright stance represents a complex task, which is achieved by integrating sensory information from the visual, vestibular and somatosensory systems. When one of these sensory inputs becomes unavailable and/or inaccurate and/or unreliable, postural control generally is degraded. One way to solve this problem is to supplement and/or substitute limited/altered/missing sensory information by providing additional sensory information to the central nervous system via an alternative sensory modality. Along these lines, we developed an original biofeedback system [1] whose underlying principle consists in supplying the user with supplementary sensory information related to foot sole pressure distribution through a tongue-placed output device (Tongue Display Unit, "TDU" [2]). The purpose of the present experiment was to assess its effectiveness in improving balance in young healthy adults.

physics.med-ph

Optimizing the Use of an Artificial Tongue-Placed Tactile Biofeedback for Improving Ankle Joint Position Sense in Humans

The performance of an artificial tongue-placed tactile biofeedback device for improving ankle joint position sense was assessed in 12 young healthy adults using an active matching task. The underlying principle of this system consists of supplying individuals with supplementary information about the position of the matching ankle relative to the reference ankle position through a tongue-placed tactile output device generating electrotactile stimulation on a 36-point (6 X 6) matrix held against the surface of the tongue dorsum. Precisely, (1) no electrodes were activated when both ankles were in a similar angular position within a predetermined "angular dead zone" (ADZ); (2) 12 electrodes (2 X 6) of the anterior and posterior zones of the matrix were activated (corresponding to the stimulation of the front and rear portion of the tongue) when the matching ankle was in a too plantarflexed and dorsiflexed position relative to the reference ankle, respectively. Two ADZ values of 0.5 degrees and 1.5 degrees were evaluated. Results showed (1) more accurate and more consistent matching performances with than without biofeedback and (2) more accurate and more consistent ankle joint matching performances when using the biofeedback device with the smaller ADZ value

physics.med-ph