Searcharxiv⌕ Search

arXiv subjects

Anthony J. Gonsalves

Publications and source records attributed to Anthony J. Gonsalves.

9 recordsLinked to original sources

Energy-resolved measurement of individual GeV muon tracks generated by electrons from a compact Laser-Plasma Accelerator

Recently, the possibility of LPA-produced muon beams has gained significant interest within the accelerator application community. Directional, multi-GeV muons can be produced via Bethe-Heitler interactions when multi-GeV electrons hit solid targets. They are highly penetrating and, thanks to the compactness of the LPA, offer a path toward a deployable, active muon source. At the BELLA Center of the Lawrence Berkeley National Laboratory, we previously unambiguously detected muons generated during the interaction of multi-GeV electron beams with a 4 meter-thick electron beam dump. A new campaign has now extended our diagnostic capabilities to single-muon trajectory reconstruction and energy measurements. The setup allowed us to individually reconstruct each muon trajectory, defined by us as a muon passing through three detectors used for the reconstruction. For a subset of events, we extracted the muon energy from the magnetic-field bending angle, demonstrating production of GeV-scale muons. This work provides a key demonstration of track-based active-source muography, which enables non-invasive 3D density mapping of concealed or inaccessible samples, and it will accelerate the development of active LPA-based muon sources where compactness, controlled directionality, low divergence, and deep penetration are required.

physics.acc-ph↗

Radiation damage to normal mammalian tissue in vivo with laser-driven protons at ultra-high instantaneous dose rate

The differential sparing of normal tissues relative to tumor control observed at ultra-high dose rates, referred to as the FLASH effect, has recently gained considerable attention. The therapeutic advantages of FLASH radiotherapy are expected to be further amplified through the use of protons and ions, which enable precise dose deposition at tumor depth while minimizing irradiation of healthy tissues proximal and distal to the target. Nevertheless, the mechanism underlying this sparing effect remains poorly understood. Laser-driven proton accelerators are capable of delivering uniquely high instantaneous dose rates in ultrashort bunches. Here, we report the first in vivo investigation of normal tissue response to laser-driven proton irradiation, with controlled exposures to 8 MeV protons, delivering total doses up to 50 Gy at 2 Gy per laser shot. Our findings reveal a reduction in tissue swelling following laser-driven proton treatment compared with X-ray irradiations at conventional dose rates. RNA sequencing identified differential gene expression associated with immune and epidermal programs following laser-driven proton irradiations at two different dose levels.

physics.med-ph↗

Generation and control of Doppler harmonics approaching $10^{22}\textrm{W/cm}^2$ on plasma mirrors

In this letter, we report Doppler harmonic generation with a relativistic plasma mirror at unprecedented intensities $>10^{21} ~\textrm{W/cm}^2$ using a PetaWatt-class laser. We show that beyond a few $10^{21} ~\textrm{W/cm}^2$ a precise control of the laser contrast at the sub-picosecond time scale becomes essential to drive the efficient generation of high-order harmonics. Such control is paramount for deploying plasma mirrors in high-field applications at PetaWatt-class laser facilities, including, for instance, their use as intensity boosters in the pursuit of the strong-field regime of quantum electrodynamics.

physics.plasm-ph↗

Measurement of directional muon beams generated at the Berkeley Lab Laser Accelerator

We present the detection of directional muon beams produced using a PW laser at the Lawrence Berkeley National Laboratory. The muon source is a multi-GeV electron beam generated in a 30 cm laser plasma accelerator interacting with a high-Z converter target. The GeV photons resulting from the interaction are converted into a high-flux, directional muon beam via pair production. By employing scintillators to capture delayed events, we were able to identify the produced muons and characterize the source. Using theoretical knowledge of the muon production process combined with simulations that are in excellent agreement with the experiments, we demonstrate that the multi-GeV electron beams produce GeV-scale muons in numbers far exceeding those from cosmic background. Laser-plasma-accelerator-based muon sources can therefore enhance muon imaging applications thanks to their compactness, directionality, and high yields, which reduce the exposure time by orders of magnitude compared to cosmic ray muons. Using the Geant4-based simulation code we developed to gain insight into the experimental results, we can design future experiments and applications based on LPA-generated muons.

physics.acc-ph↗

A Renewable Double Plasma Mirror For Petawatt-class Lasers

Exceptional pulse contrast can be critical for ultraintense laser experiments, particularly when using solid density targets, and their use is becoming widespread. However, current plasma mirror technology is becoming inadequate for the new generation of high repetition rate, high power lasers now available. We describe a novel double plasma mirror configuration based on renewable, free standing, ultrathin liquid crystal films tested at the BELLA Petawatt Laser Center. Although operating at a repetition rate of several shots per minute, this system can be scaled to a high repetition rate exceeding 1 Hz and represents an important step towards enabling sustained, continuous operation of plasma mirrors. We demonstrate an improvement of two to three orders of magnitude in contrast and a total throughput of 80%. We present the first measurements of a beam reflected from a single or double plasma mirror system using a wavefront sensor, showing a well preserved wavefront and spatial mode. Finally, we introduce a model that predicts the total throughput through this double plasma mirror. This is the first model that accurately predicts the peak reflectivity of a plasma mirror when given the laser temporal profile.

physics.plasm-ph↗

Control Systems and Data Management for High-Power Laser Facilities

The next generation of high-power lasers enables repetition of experiments at orders of magnitude higher frequency than was possible using the prior generation. Facilities requiring human intervention between laser repetitions need to adapt in order to keep pace with the new laser technology. A distributed networked control system can enable laboratory-wide automation and feedback control loops. These higher-repetition-rate experiments will create enormous quantities of data. A consistent approach to managing data can increase data accessibility, reduce repetitive data-software development, and mitigate poorly organized metadata. An opportunity arises to share knowledge of improvements to control and data infrastructure currently being undertaken. We compare platforms and approaches to state-of-the-art control systems and data management at high-power laser facilities, and we illustrate these topics with case studies from our community.

physics.ins-det↗

Online Charge Measurement for Petawatt Laser-Driven Ion Acceleration

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Pre-clinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultra-high instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a non-invasive diagnostic to measure the charge of the accelerated ion bunch. It enables online dose measurements in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics such as radiochromic films, a Thomson parabola spectrometer and a scintillator.

physics.acc-ph↗

Spatio-temporal structure of a Petawatt femtosecond laser beam

The development of optical metrology suited to ultrafast lasers has played a key role in the progress of these light sources in the last few decades. Measurement techniques providing the complete $E$-field of ultrashort laser beams in both time and space are now being developed. Yet, they had so far not been applied to the most powerful ultrashort lasers, which reach the PetaWatt range by pushing the Chirped Pulse Amplification scheme to its present technical limits. This situation left doubts on their actual performance, and in particular on the peak intensity they can reach at focus. In this article we present the first complete spatio-temporal characterization of a PetaWatt femtosecond laser operating at full intensity, the BELLA laser, using two recently-developed independent measurement techniques. Our results demonstrate that, with adequate optimization, the CPA technique is still suitable at these extreme scales, i.e., it is not inherently limited by spatio-temporal couplings. We also show how these measurements provide unprecedented insight into the physics and operation regime of such laser systems.

physics.optics↗

Plasma Equilibrium inside Various Cross-Section Capillary Discharges

Plasma properties inside a hydrogen-filled capillary discharge waveguide were modeled with dissipative magnetohydrodynamic simulations to enable analysis of capillaries of circular and square cross-sections implying that square capillaries can be used to guide circularly-symmetric laser beams. When the quasistationary stage of the discharge is reached, the plasma and temperature in the vicinity of the capillary axis has almost the same profile for both the circular and square capillaries. The effect of cross-section on the electron beam focusing properties were studied using the simulation-derived magnetic field map. Particle tracking simulations showed only slight effects on the electron beam symmetry in the horizontal and diagonal directions for square capillary.