SearcharxivSearch

arXiv subjects

Antoine Cavagna

Publications and source records attributed to Antoine Cavagna.

6 recordsLinked to original sources

Sub-2-Cycle, Terawatt Pulses via Double-Stage Multi-Pass Cell Compression of an Yb Laser

We report a terawatt-class, sub-2-cycle post-compressed Yb-based laser system operating at kHz repetition rate. 18 mJ, 400 fs pulses delivered at 1 kHz by a commercial Yb:YAG laser are spectrally broadened and temporally compressed in a double-stage multi-pass cell setup featuring an argon-filled Herriott-type cell followed by a helium-filled array-type cell, achieving an overall compression factor of 65. The resulting compressed pulses are measured to have 6.2 fs duration (1.8 optical cycles at 1030 nm) and 12.5 mJ energy, corresponding to 1.4 TW effective peak power. To the best of our knowledge, this constitutes the highest peak power reported to date for a few-cycle, kHz-repetition-rate, post-compressed Yb laser system. Focused intensity measurements yield a normalized vector potential of a0 = 3.0, confirming the applicability of this light source for laser wakefield acceleration.

physics.optics

Differential pumping for kHz operation of a Laser Wakefield accelerator based on a continuously flowing Hydrogen gas jet

Laser-Wakefield Accelerators (LWFA) running at kHz repetition rates hold great potential for applications. They typically operate with low-energy, highly compressed laser pulses focused in high-pressure gas targets. Experiments have shown that the best-quality electron beams are achieved using Hydrogen gas targets. However, continuous operation with Hydrogen requires a dedicated pumping system. In this work, we present a method for designing a differential pumping system, which we successfully implemented in our experiments. This enabled the first demonstration of continuous operation of a kHz LWFA using a high-pressure Hydrogen gas jet. The system effectively maintained a pressure below 3e-4 mbar, even with a free-flowing gas jet operating at 140 bar backing pressure. Numerical fluid dynamics and optical simulations were used to guide and validate the system's design.

physics.plasm-ph

Continuous relativistic high-harmonic generation from a kHz liquid-sheet plasma mirror

We report on continuous high-harmonic generation at 1 kHz repetition rate from a liquid-sheet plasma mirror driven by relativistic-intensity near-single-cycle light transients. Through precise control of both the surface plasma density gradient and the driving light waveform, we can produce highly stable and reproducible extreme ultraviolet spectral quasi-continua, corresponding to the generation of stable kHz-trains of isolated attosecond pulses in the time domain. This confirms the exciting potential of liquid sheet targets as one of the building blocks of future high-power attosecond lasers.

physics.plasm-ph

Beam Pointing of Relativistic High-order Harmonics Genrated on a Nonuniform Pre-plasma

The use of tunable pre-pulse is a common technique to enhance the high-order harmonic generation from surface plasma. The shape and dynamic of the electron density, the degree of ionization and its rate, and the plasma heating are influenced by the pre-pulse properties. Non-uniform pre-pulse could cause a spatially varying density map to the pre-plasma region, which serves as the spectrally up-conversion and reflection surface. The corresponding geometrical feature and plasma nature under laser field will affect the harmonic emission properties. In this study, the variation in harmonic beam pointing due to the electron density shape was investigated. Particle-in-cell simulations demonstrated that both plasma hydrodynamics and geometrical optical effect induce the deviation of harmonic beam from specular reflection. This research contributes to the understanding of the surface plasma dynamics during high harmonic generation process.

physics.plasm-ph

Optical ionization effects in kHz laser wakefield acceleration with few-cycle pulses

We present significant advances in Laser Wakefield Acceleration (LWFA) operating at a 1 kHz repetition rate, employing a sub-TW, few-femtosecond laser and a continuously flowing hydrogen gas target. We conducted the first comprehensive study assessing how the nature of the gas within the target influences accelerator performance. This work confirms and elucidates the superior performance of hydrogen in kHz LWFA. Our system generates quasi-monoenergetic electron bunches with energies up to 10 MeV, bunch charges of 2 pC, and angular divergences of 15 mrad. Notably, our novel scheme relying on differential pumping enables continuous operation at kHz repetition rates, contrasting with previous systems that operated in burst mode to achieve similar beam properties. Particle-in-cell simulations explain hydrogen's superior performances: the ionization effects in nitrogen and helium distort the laser pulse, negatively impacting accelerator performance. These effects are strongly mitigated in hydrogen plasma, thereby enhancing beam quality. This analysis represents a significant step forward in optimizing and understanding kHz LWFA. It underscores the critical role of hydrogen and the imperative need to develop hydrogen-compatible target systems capable of managing high repetition rates, as exemplified by our differential pumping system. These advances lay the groundwork for further developments in high-repetition-rate LWFA technology.

physics.plasm-ph

Simple few-shot method for spectrally resolving the wavefront of an ultrashort laser pulse

We present a novel and straightforward approach for the spatio-spectral characterization of ultrashort pulses. This minimally intrusive method relies on placing a mask with specially arranged pinholes in the beam path before the focusing optic and retrieving the spectrally-resolved laser wavefront from the speckle pattern produced at focus. We test the efficacy of this new method by accurately retrieving chromatic aberrations, such as pulse front tilt, pulse front curvature, and higher-order aberrations introduced by a spherical lens. The simplicity and scalability of this method, combined with its compatibility with single-shot operation, make it a promising candidate to become a new standard diagnostic tool in high-intensity laser facilities.

physics.optics