SearcharxivSearch

arXiv subjects

Antoine Klauser

Publications and source records attributed to Antoine Klauser.

13 recordsLinked to original sources

HyperFitS -- Hypernetwork Fitting Spectra for metabolic quantification of ${}^1$H MR spectroscopic imaging

Purpose: Proton magnetic resonance spectroscopic imaging ($^1$H MRSI) enables the mapping of whole-brain metabolites concentrations in-vivo. However, a long-standing problem for its clinical applicability is the metabolic quantification, which can require extensive time for spectral fitting. Recently, deep learning methods have been able to provide whole-brain metabolic quantification in only a few seconds. However, neural network implementations often lack configurability and require retraining to change predefined parameter settings. Methods: We introduce HyperFitS, a hypernetwork for spectral fitting for metabolite quantification in whole-brain $^1$H MRSI that flexibly adapts to a broad range of baseline corrections and water suppression factors. Metabolite maps of human subjects acquired at 3T and 7T with isotropic resolutions of 10 mm, 3.4 mm and 2 mm by water-suppressed and water-unsuppressed MRSI were quantified with HyperFitS and compared to conventional LCModel fitting. Results: Metabolic maps show a substantial agreement between the new and gold-standard methods, with significantly faster fitting times by HyperFitS. Quantitative results further highlight the impact of baseline parametrization on metabolic quantification, which can alter results by up to 30%. Conclusion: HyperFitS shows strong agreement with state-of-the-art conventional methods, while reducing processing times from hours to a few seconds. Compared to prior deep learning based spectral fitting methods, HyperFitS enables a wide range of configurability and can adapt to data quality acquired with multiple protocols and field strengths without retraining.

cs.LG

Deep learning water-unsuppressed MRSI at ultra-high field for simultaneous quantitative metabolic, susceptibility and myelin water imaging

Purpose: Magnetic Resonance Spectroscopic Imaging (MRSI) maps endogenous brain metabolism while suppressing the overwhelming water signal. Water-unsuppressed MRSI (wu-MRSI) allows simultaneous imaging of water and metabolites, but large water sidebands cause challenges for metabolic fitting. We developed an end-to-end deep-learning pipeline to overcome these challenges at ultra-high field. Methods:Fast high-resolution wu-MRSI was acquired at 7T with non-cartesian ECCENTRIC sampling and ultra-short echo time. A water and lipid removal network (WALINET+) was developed to remove lipids, water signal, and sidebands. MRSI reconstruction was performed by DeepER and a physics-informed network for metabolite fitting. Water signal was used for absolute metabolite quantification, quantitative susceptibility mapping (QSM), and myelin water fraction imaging (MWF). Results: WALINET+ provided the lowest NRMSE (< 2%) in simulations and in vivo the smallest bias (< 20%) and limits-of-agreement (+-63%) between wu-MRSI and ws-MRSI scans. Several metabolites such as creatine and glutamate showed higher SNR in wu-MRSI. QSM and MWF obtained from wu-MRSI and GRE showed good agreement with 0 ppm/5.5% bias and +-0.05 ppm/ +- 12.75% limits-of-agreement. Conclusion: High-quality metabolic, QSM, and MWF mapping of the human brain can be obtained simultaneously by ECCENTRIC wu-MRSI at 7T with 2 mm isotropic resolution in 12 min. WALINET+ robustly removes water sidebands while preserving metabolite signal, eliminating the need for water suppression and separate water acquisitions.

eess.IV

Optimization and application of ultra-high field preclinical high-resolution and 3D 1H-MRSI using compressed sensing

Proton magnetic resonance spectroscopic imaging (1H-MRSI) at ultra-high field has seen an increase in usage in the preclinical field. Challenges related to long acquisition time and low concentration of brain metabolites in the rodent brain have led to the development and application of acceleration schemes for 3D-1H-MRSI, such the undersampling technique Compressed Sensing (CS). This present study aims to explore the CS tool in the context of preclinical in vivo application in order to achieve high-resolution MRSI acquisition in both 2D with an in-plane increase and 3D/multi-slice acquisition with through-plane. The parameters are explored to achieve the highest acceleration possible as a way to make 3D as time efficient as possible. Results of the parameter study showed that an acceleration factor (AF) of 4 was possible with the right sampling size of the core at the center of the k-space. With this specific set, higher matrix size resulting in sub 1 {\mu}L nominal voxel size was explored with 2D-FID-MRSI and 9 supplementary phase-encoding/slices were added to achieve 3D-FID-MRSI. The spectral quality and the metabolic maps were accurate enough in the comparison with the non-accelerated 2D-FID-MRSI, within the slice of interest. Issues related with the point spread function (PSF) were noted throughout the different usage of CS. Our work presents a robust and effective protocol to achieve 3D-1H-MRSI using CS in order to reach an acquisition time below the 30 minutes bar, with minimal technical limitations and high-quality acquisition.

physics.med-ph

Rosette spectroscopic imaging for whole-brain metabolite mapping at 7T: acceleration potential and reproducibility

Whole-brain proton magnetic resonance spectroscopic imaging (1H-MRSI) is a non-invasive technique for assessing neurochemical distribution in the brain, offering valuable insights into brain functions and neural diseases. It greatly benefits from the improved SNR at ultrahigh field strengths ($\geq$7T). However, 1H-MRSI still faces several challenges, such as long acquisition time and severe signal contaminations from water and lipids. In this study, 2D and 3D short TR/TE 1H-FID-MRSI sequences using rosette trajectories were developed with spatial resolutions of 4.48$\times$4.48 mm$^2$ and 4.48$\times$4.48$\times$4.50 mm$^3$, respectively. Water signals were suppressed using an optimized Five-variable-Angle-gaussian-pulses-with-ShorT-total-duration of 76 ms (FAST) water suppression scheme, and lipid signals were removed using the L2 regularization method. Metabolic maps of major 1H metabolites were obtained within 5:40 min with 16 averages and 1 average for the 2D and 3D acquisitions, respectively. Excellent inter-session reproducibility was shown, with the coefficients of variance (CV) being lower than 6% for N-Acetyle-L-aspartic acid (NAA), Glutamate (Glu), Choline Chloride and glycerophosphocholine (tCho), Creatine and Phosphocreatine (tCr), and Glycine and Myo-inositol (Gly+Ins). To explore the potential of further accelerating the acquisition, compressed sensing was applied retrospectively to the 3D datasets. The structural similarity index (SSIM) remained above 0.85 and 0.8 until $R = 2$ and $R = 3$ for the metabolite maps of Glu, NAA, tCr, and tCho, indicating the possibility for further reduction of acquisition time to around 2min.

physics.med-ph

WALINET: A water and lipid identification convolutional Neural Network for nuisance signal removal in 1H MR Spectroscopic Imaging

Purpose. Proton Magnetic Resonance Spectroscopic Imaging (1H-MRSI) provides non-invasive spectral-spatial mapping of metabolism. However, long-standing problems in whole-brain 1H-MRSI are spectral overlap of metabolite peaks with large lipid signal from scalp, and overwhelming water signal that distorts spectra. Fast and effective methods are needed for high-resolution 1H-MRSI to accurately remove lipid and water signals while preserving the metabolite signal. The potential of supervised neural networks for this task remains unexplored, despite their success for other MRSI processing. Methods. We introduce a deep-learning method based on a modified Y-NET network for water and lipid removal in whole-brain 1H-MRSI. The WALINET (WAter and LIpid neural NETwork) was compared to conventional methods such as the state-of-the-art lipid L2 regularization and Hankel-Lanczos singular value decomposition (HLSVD) water suppression. Methods were evaluated on simulated and in-vivo whole-brain MRSI using NMRSE, SNR, CRLB, and FWHM metrics. Results. WALINET is significantly faster and needs 8s for high-resolution whole-brain MRSI, compared to 42 minutes for conventional HLSVD+L2. Quantitative analysis shows WALINET has better performance than HLSVD+L2: 1) more lipid removal with 41% lower NRMSE, 2) better metabolite signal preservation with 71% lower NRMSE in simulated data, 155% higher SNR and 50% lower CRLB in in-vivo data. Metabolic maps obtained by WALINET in healthy subjects and patients show better gray/white-matter contrast with more visible structural details. Conclusions. WALINET has superior performance for nuisance signal removal and metabolite quantification on whole-brain 1H-MRSI compared to conventional state-of-the-art techniques. This represents a new application of deep-learning for MRSI processing, with potential for automated high-throughput workflow.

eess.IV

Deep-ER: Deep Learning ECCENTRIC Reconstruction for fast high-resolution neurometabolic imaging

Introduction: Altered neurometabolism is an important pathological mechanism in many neurological diseases and brain cancer, which can be mapped non-invasively by Magnetic Resonance Spectroscopic Imaging (MRSI). Advanced MRSI using non-cartesian compressed-sense acquisition enables fast high-resolution metabolic imaging but has lengthy reconstruction times that limits throughput and needs expert user interaction. Here, we present a robust and efficient Deep Learning reconstruction to obtain high-quality metabolic maps. Methods: Fast high-resolution whole-brain metabolic imaging was performed at 3.4 mm$^3$ isotropic resolution with acquisition times between 4:11-9:21 min:s using ECCENTRIC pulse sequence on a 7T MRI scanner. Data were acquired in a high-resolution phantom and 27 human participants, including 22 healthy volunteers and 5 glioma patients. A deep neural network using recurring interlaced convolutional layers with joint dual-space feature representation was developed for deep learning ECCENTRIC reconstruction (Deep-ER). 21 subjects were used for training and 6 subjects for testing. Deep-ER performance was compared to conventional iterative Total Generalized Variation reconstruction using image and spectral quality metrics. Results: Deep-ER demonstrated 600-fold faster reconstruction than conventional methods, providing improved spatial-spectral quality and metabolite quantification with 12%-45% (P<0.05) higher signal-to-noise and 8%-50% (P<0.05) smaller Cramer-Rao lower bounds. Metabolic images clearly visualize glioma tumor heterogeneity and boundary. Conclusion: Deep-ER provides efficient and robust reconstruction for sparse-sampled MRSI. The accelerated acquisition-reconstruction MRSI is compatible with high-throughput imaging workflow. It is expected that such improved performance will facilitate basic and clinical MRSI applications.

eess.IV

SISMIK for brain MRI: Deep-learning-based motion estimation and model-based motion correction in k-space

MRI, a widespread non-invasive medical imaging modality, is highly sensitive to patient motion. Despite many attempts over the years, motion correction remains a difficult problem and there is no general method applicable to all situations. We propose a retrospective method for motion estimation and correction to tackle the problem of in-plane rigid-body motion, apt for classical 2D Spin-Echo scans of the brain, which are regularly used in clinical practice. Due to the sequential acquisition of k-space, motion artifacts are well localized. The method leverages the power of deep neural networks to estimate motion parameters in k-space and uses a model-based approach to restore degraded images to avoid ''hallucinations''. Notable advantages are its ability to estimate motion occurring in high spatial frequencies without the need of a motion-free reference. The proposed method operates on the whole k-space dynamic range and is moderately affected by the lower SNR of higher harmonics. As a proof of concept, we provide models trained using supervised learning on 600k motion simulations based on motion-free scans of 43 different subjects. Generalization performance was tested with simulations as well as in-vivo. Qualitative and quantitative evaluations are presented for motion parameter estimations and image reconstruction. Experimental results show that our approach is able to obtain good generalization performance on simulated data and in-vivo acquisitions. We provide a Python implementation at https://gitlab.unige.ch/Oscar.Dabrowski/sismik_mri/.

eess.IV

Noise-reduction techniques for 1H-FID-MRSI at 14.1T: Monte-Carlo validation & in vivo application

Proton magnetic resonance spectroscopic imaging (1H-MRSI) is a powerful tool that enables the multidimensional non-invasive mapping of the neurochemical profile at high-resolution over the entire brain. The constant demand for higher spatial resolution in 1H-MRSI led to increased interest in post-processing-based denoising methods aimed at reducing noise variance. The aim of the present study was to implement two noise-reduction techniques, the Marchenko-Pastur principal component analysis (MP-PCA) based denoising and the low-rank total generalized variation (LR-TGV) reconstruction, and to test their potential and impact on preclinical 14.1T fast in vivo 1H-FID-MRSI datasets. Since there is no known ground truth for in vivo metabolite maps, additional evaluations of the performance of both noise-reduction strategies were conducted using Monte-Carlo simulations. Results showed that both denoising techniques increased the apparent signal-to-noise ratio SNR while preserving noise properties in each spectrum for both in vivo and Monte-Carlo datasets. Relative metabolite concentrations were not significantly altered by either methods and brain regional differences were preserved in both synthetic and in vivo datasets. Increased precision of metabolite estimates was observed for the two methods, with inconsistencies noted on lower concentrated metabolites. Our study provided a framework on how to evaluate the performance of MP-PCA and LR-TGV methods for preclinical 1H-FID MRSI data at 14.1T. While gains in apparent SNR and precision were observed, concentration estimations ought to be treated with care especially for low-concentrated metabolites.

physics.med-ph

Fast high-resolution metabolite mapping in the rat brain using 1H-FID-MRSI at 14.1T

Magnetic resonance spectroscopic imaging (MRSI) enables the simultaneous non-invasive acquisition of MR spectra from multiple spatial locations inside the brain. While 1H-MRSI is increasingly used in the human brain, it is not yet widely applied in the preclinical settings, mostly because of difficulties specifically related to very small nominal voxel size in the rodent brain and low concentration of brain metabolites, resulting in low signal-to-noise ratio SNR. In this context, we implemented a free induction decay 1H-MRSI sequence (1H-FID-MRSI) in the rat brain at 14.1T. We combined the advantages of 1H-FID-MRSI with the ultra-high magnetic field to achieve higher SNR, coverage and spatial resolution in the rodent brain, and developed a custom dedicated processing pipeline with a graphical user interface: MRS4Brain toolbox. LCModel fit, using the simulated metabolite basis-set and in-vivo measured MM, provided reliable fits for the data at acquisition delays of 1.3 and 0.94 ms. The resulting Cram\'er-Rao lower bounds were sufficiently low (<30%) for eight metabolites of interest, leading to highly reproducible metabolic maps. Similar spectral quality and metabolic maps were obtained between 1 and 2 averages, with slightly better contrast and brain coverage due to increased SNR in the latter case. Furthermore, the obtained metabolic maps were accurate enough to confirm the previously known brain regional distribution of some metabolites. The acquisitions proved high reproducibility over time. We demonstrated that the increased SNR and spectral resolution at 14.1T can be translated into high spatial resolution in 1H-FID-MRSI of the rat brain in 13 minutes, using the sequence and processing pipeline described herein. High-resolution 1H-FID-MRSI at 14.1T provided reproducible and high-quality metabolic mapping of brain metabolites with significantly reduced technical limitations.

physics.med-ph

ECCENTRIC: a fast and unrestrained approach for high-resolution in vivo metabolic imaging at ultra-high field MR

A novel method for fast and high-resolution metabolic imaging, called ECcentric Circle ENcoding TRajectorIes for Compressed sensing (ECCENTRIC), has been developed and implemented at 7 Tesla MRI. ECCENTRIC is a non-Cartesian spatial-spectral encoding method optimized to accelerate magnetic resonance spectroscopic imaging (MRSI) with high signal-to-noise at ultra-high field. The approach provides flexible and random ($k,t$) sampling without temporal interleaving to improve spatial response function and spectral quality. ECCENTRIC needs low gradient amplitudes and slew-rates that reduces electrical, mechanical and thermal stress of the scanner hardware, and is robust to timing imperfection and eddy-current delays. Combined with a model-based low-rank reconstruction, this approach enables simultaneous imaging of up to 14 metabolites over the whole-brain at 2-3mm isotropic resolution in 4-10 minutes. In healthy volunteers ECCENTRIC demonstrated unprecedented spatial mapping of fine structural details of human brain neurochemistry. This innovative tool introduces a novel approach to neuroscience, providing new insights into the exploration of brain activity and physiology.

physics.med-ph

Adjacent Spin Operator Dynamical Structure Factor of the S=1/2 Heisenberg Chain

Considering the adjacent spin operators $S^z_jS^z_{j+1}$ and $S^-_jS^-_{j+1}$ in the S=1/2 Heisenberg chain, we give a determinant representation of their form factors. The dynamical structure factors of the respective operators are computed over the whole Brillouin zone in several magnetic fields and the resulting signal is analyzed in terms of excitation types. Among other results, we find that the $S^z_jS^z_{j+1}$ dynamical structure factor carries a large weight of the 4-spinon excitations which are distinguishable from the 2-spinon signal because they are located outside the 2-spinon spectrum.

cond-mat.str-el

Equilibrium thermodynamic properties of interacting two-component bosons in one dimension

The interplay of quantum statistics, interactions and temperature is studied within the framework of the bosonic two-component theory with repulsive delta-function interaction in one dimension. We numerically solve the thermodynamic Bethe Ansatz and obtain the equation of state as a function of temperature and of the interaction strength, the relative chemical potential and either the total chemical potential or a fixed number of particles, allowing to quantify the full crossover behaviour of the system between its low-temperature ferromagnetic and high-temperature unpolarized regime, and from the low coupling decoherent regime to the fermionization regime at high interaction.

cond-mat.quant-gas

The Spin-Exchange Dynamical Structure Factor of the S=1/2 Heisenberg Chain

We determine the spin-exchange dynamical structure factor of the Heisenberg spin chain, as is measured by indirect Resonant Inelastic X-ray Scattering (RIXS). We find that two-spin RIXS excitations nearly entirely fractionalize into *two spinon* states. These share the same continuum lower bound as single-spin neutron scattering excitations, even if the relevant final states belong to orthogonal symmetry sectors. The RIXS spectral weight is mainly carried by higher-energy excitations, and is beyond the reach of the low-energy effective theories of Luttinger liquid type.

cond-mat.str-el