Searcharxiv⌕ Search

arXiv subjects

Anton S. Tremsin

Publications and source records attributed to Anton S. Tremsin.

5 recordsLinked to original sources

Single-exposure elemental differentiation and texture-sensitive phase-retrieval imaging with a neutron counting micro-channel plate detector

Micro-channel plate (MCP) detectors, when used at pulsed-neutron-source instruments, offer the possibility of high spatial resolution and high contrast imaging with pixel-level spectroscopic information. Here we demonstrate the possibility of multimodal analysis including total neutron cross-section spectra measurements, quantitative material differentiation imaging and texture-sensitive in-line phase imaging, from a single exposure using an MCP detector. This multimodal approach operates in full-field imaging mode, with the neutron transmission spectra acquired at each individual detector pixel. Due to the polychromatic nature of the beam and spectroscopic resolving capability of the detector, no energy scanning is required. Good agreement with the library reference data is demonstrated for neutron cross-section spectra measurements. Two different images corresponding to two selected energy bandwidths are used for elemental differentiation imaging. Moreover, the presence of changes in texture, i.e., preferred grain orientation, in the sample is identified from our phase-retrieval imaging results.

cond-mat.mtrl-sci↗

Antiferromagnetic real-space configuration probed by dichroism in scattered x-ray beams with orbital angular momentum

X-ray beams with orbital angular momentum (OAM) are a promising tool for x-ray characterization techniques. Beams with OAM have a helicity--an azimuthally varying phase--which leads to a gradient of the light field. New material properties can be probed by utilizing the helicity of an OAM beam. Here, we demonstrate a novel dichroic effect in resonant diffraction from an artificial antiferromagnet with a topological defect. We found that the scattered OAM beam has circular dichroism at the antiferromagnetic Bragg peak whose sign is coupled to its helicity, which reveals the real-space configuration of the antiferromagnetic ground state. Thermal cycling of the artificial antiferromagnet can change the ground state, as indicated by reversal of the sign of circular dichroism. This result is one of the first demonstrations of a soft x-ray spectroscopy characterization technique utilizing the OAM of x-rays. This helicity-dependent circular dichroism exemplifies the potential to utilize OAM beams to probe matter in a way that is inaccessible using currently available x-ray techniques.

cond-mat.mtrl-sci↗

Needs, trends, and advances in scintillators for radiographic imaging and tomography

Scintillators are important materials for radiographic imaging and tomography (RadIT), when ionizing radiations are used to reveal internal structures of materials. Since its invention by Röntgen, RadIT now come in many modalities such as absorption-based X-ray radiography, phase contrast X-ray imaging, coherent X-ray diffractive imaging, high-energy X- and $γ-$ray radiography at above 1 MeV, X-ray computed tomography (CT), proton imaging and tomography (IT), neutron IT, positron emission tomography (PET), high-energy electron radiography, muon tomography, etc. Spatial, temporal resolution, sensitivity, and radiation hardness, among others, are common metrics for RadIT performance, which are enabled by, in addition to scintillators, advances in high-luminosity accelerators and high-power lasers, photodetectors especially CMOS pixelated sensor arrays, and lately data science. Medical imaging, nondestructive testing, nuclear safety and safeguards are traditional RadIT applications. Examples of growing or emerging applications include space, additive manufacturing, machine vision, and virtual reality or `metaverse'. Scintillator metrics such as light yield and decay time are correlated to RadIT metrics. More than 160 kinds of scintillators and applications are presented during the SCINT22 conference. New trends include inorganic and organic scintillator heterostructures, liquid phase synthesis of perovskites and $μ$m-thick films, use of multiphysics models and data science to guide scintillator development, structural innovations such as photonic crystals, nanoscintillators enhanced by the Purcell effect, novel scintillator fibers, and multilayer configurations. Opportunities exist through optimization of RadIT with reduced radiation dose, data-driven measurements, photon/particle counting and tracking methods supplementing time-integrated measurements, and multimodal RadIT.

physics.ins-det↗

A multimodal operando neutron study of the phase evolution in a graphite electrode

Obtaining a complete picture of local processes still poses a significant challenge in battery research. Here we demonstrate an in-situ combination of multimodal neutron imaging with neutron diffraction for spatially resolved operando observations of the lithiation-delithiation of a graphite electrode in a Li-ion battery cell. Throughout the lithiation-delithiation process we image the Li distribution based on the local beam attenuation. Simultaneously, we observe the development of the lithiated graphite phases as a function of cycling time and electrode thickness and integral throughout its volume by diffraction contrast imaging and diffraction, respectively. While the conventional imaging data allows to observe the Li uptake in graphite already during the formation of the solid electrolyte interphase, diffraction indicates the onset and development of the Li insertion/extraction globally, which supports the local structural transformation observations by diffraction contrast imaging.

cond-mat.mtrl-sci↗

Synchrotron Microtomography and Neutron Radiography Characterization of the Microstruture and Water Absorption of Concrete from Pompeii

There is renewed interest in using advanced techniques to characterize ancient Roman concrete. In the present work, samples were drilled from the "Hospitium" in Pompeii and were analyzed by synchrotron microtomography (uCT) and neutron radiography to study how the microstructure, including the presence of induced cracks, affects their water adsorption. The water distribution and absorptivity were quantified by neutron radiography. The 3D crack propagation, pore size distribution and orientation, tortuosity, and connectivity were analyzed from uCT results using advanced imaging methods. The concrete characterization also included classical methods (e.g., differential thermal-thermogravimetric, X-ray diffractometry, and scanning electron microscopy). Ductile fracture patterns were observed once cracks were introduced. When compared to Portland cement mortar/concrete, Pompeii samples had relatively high porosity, low connectivity, and similar coefficient of capillary penetration. In addition, the permeability was predicted from models based on percolation theory and the pore structure data to evaluate the fluid transport properties.

physics.app-ph↗