SearcharxivSearch

arXiv subjects

Antonino Chiummo

Publications and source records attributed to Antonino Chiummo.

3 recordsLinked to original sources

Mechanical Long Baseline Differential Gradiometers as Low Frequency Gravitational Wave Detectors

We present a new differential mechanical gradiometer for the detection of low-frequency Gravitational Waves. The frequency range is 0.05 to 1 Hz, a frequency gap not covered either by future space-based detectors such as LISA or by ground-based observatories such as Einstein Telescope or Cosmic Explorer. The proposed detection principle is similar to antennas based on torsion pendulums but solves the problem of physical confinement of these antennas by operating vertically and by having a counterweight at one end of each bar and a mass suspended from a long wire at the other. With this configuration, we enlarge the gravitational force acting on the system \textit{without} changing the moment of inertia of the system, so that we move from a signal $Δθ$ of the order of $Δθ= h$, where h is the amplitude of the gravitational wave, to a signal of the order $Δθ= h\frac{L}{D}$, where D is the length of the arm and L is the length of the wire suspending the test mass. This configuration is a further evolution of the recent development of tiltmeters and balances with double suspended arms and interferometric read-out, where the main working principles are already tested. The expected sensitivity will be discussed with respect to the proposed parameters and the present technology.

gr-qc

Scattered light noise characterisation at the Virgo interferometer with tvf-EMD adaptive algorithm

A methodology of adaptive time series analysis, based on Empirical Mode Decomposition (EMD), and on its time varying version tvf-EMD has been applied to strain data from the gravitational wave interferometer (IFO) Virgo in order to characterise scattered light noise affecting the sensitivity of the IFO in the detection frequency band. Data taken both during hardware injections, when a part of the IFO is put in oscillation for detector characterisation purposes, and during periods of science mode, when the IFO is fully locked and data are used for the detection of gravitational waves, were analysed. The adaptive nature of the EMD and tvf-EMD algorithms allows them to deal with nonlinear non-stationary data and hence they are particularly suited to characterise scattered light noise which is an intrinsically nonlinear and non-stationary noise. Obtained results show that tvf-EMD algorithm allows to obtain more precise results compared to the EMD algorithm, yielding higher cross-correlation values with the auxiliary channels that are the culprits of scattered light noise.

astro-ph.IM

Vacuum squeezed light for atomic memories at the D2 cesium line

We report the experimental generation of squeezed light at 852 nm, locked on the Cesium D2 line. 50% of noise reduction down to 50 kHz has been obtained with a doubly resonant optical parametric oscillator operating below threshold, using a periodically-polled KTP crystal. This light is directly utilizable with Cesium atomic ensembles for quantum networking applications

physics.optics