SearcharxivSearch

arXiv subjects

Antonio Amorim

Publications and source records attributed to Antonio Amorim.

11 recordsLinked to original sources

Improving constraints on the extended mass distribution in the Galactic Center with stellar orbits

Studying the orbital motion of stars around Sagittarius A* in the Galactic Center provides a unique opportunity to probe the gravitational potential near the supermassive black hole at the heart of our Galaxy. Interferometric data obtained with the GRAVITY instrument at the Very Large Telescope Interferometer (VLTI) since 2016 has allowed us to achieve unprecedented precision in tracking the orbits of these stars. GRAVITY data have been key to detecting the in-plane, prograde Schwarzschild precession of the orbit of the star S2, as predicted by General Relativity. By combining astrometric and spectroscopic data from multiple stars, including S2, S29, S38, and S55 - for which we have data around their time of pericenter passage with GRAVITY - we can now strengthen the significance of this detection to an approximately $10 σ$ confidence level. The prograde precession of S2's orbit provides valuable insights into the potential presence of an extended mass distribution surrounding Sagittarius A*, which could consist of a dynamically relaxed stellar cusp comprised of old stars and stellar remnants, along with a possible dark matter spike. Our analysis, based on two plausible density profiles - a power-law and a Plummer profile - constrains the enclosed mass within the orbit of S2 to be consistent with zero, establishing an upper limit of approximately $1200 \, M_\odot$ with a $1 σ$ confidence level. This significantly improves our constraints on the mass distribution in the Galactic Center. Our upper limit is very close to the expected value from numerical simulations for a stellar cusp in the Galactic Center, leaving little room for a significant enhancement of dark matter density near Sagittarius A*.

astro-ph.GA

The GRAVITY+ Project: Towards All-sky, Faint-Science, High-Contrast Near-Infrared Interferometry at the VLTI

The GRAVITY instrument has been revolutionary for near-infrared interferometry by pushing sensitivity and precision to previously unknown limits. With the upgrade of GRAVITY and the Very Large Telescope Interferometer (VLTI) in GRAVITY+, these limits will be pushed even further, with vastly improved sky coverage, as well as faint-science and high-contrast capabilities. This upgrade includes the implementation of wide-field off-axis fringe-tracking, new adaptive optics systems on all Unit Telescopes, and laser guide stars in an upgraded facility. GRAVITY+ will open up the sky to the measurement of black hole masses across cosmic time in hundreds of active galactic nuclei, use the faint stars in the Galactic centre to probe General Relativity, and enable the characterisation of dozens of young exoplanets to study their formation, bearing the promise of another scientific revolution to come at the VLTI.

astro-ph.IM

Faint objects in motion: the new frontier of high precision astrometry

Sky survey telescopes and powerful targeted telescopes play complementary roles in astronomy. In order to investigate the nature and characteristics of the motions of very faint objects, a flexibly-pointed instrument capable of high astrometric accuracy is an ideal complement to current astrometric surveys and a unique tool for precision astrophysics. Such a space-based mission will push the frontier of precision astrometry from evidence of Earth-mass habitable worlds around the nearest stars, to distant Milky Way objects, and out to the Local Group of galaxies. As we enter the era of the James Webb Space Telescope and the new ground-based, adaptive-optics-enabled giant telescopes, by obtaining these high precision measurements on key objects that Gaia could not reach, a mission that focuses on high precision astrometry science can consolidate our theoretical understanding of the local Universe, enable extrapolation of physical processes to remote redshifts, and derive a much more consistent picture of cosmological evolution and the likely fate of our cosmos. Already several missions have been proposed to address the science case of faint objects in motion using high precision astrometry missions: NEAT proposed for the ESA M3 opportunity, micro-NEAT for the S1 opportunity, and Theia for the M4 and M5 opportunities. Additional new mission configurations adapted with technological innovations could be envisioned to pursue accurate measurements of these extremely small motions. The goal of this White Paper is to address the fundamental science questions that are at stake when we focus on the motions of faint sky objects and to briefly review instrumentation and mission profiles.

astro-ph.IM

GRAVITY acquisition camera: characterization results

GRAVITY acquisition camera implements four optical functions to track multiple beams of Very Large Telescope Interferometer (VLTI): a) pupil tracker: a $2 \times 2$ lenslet images four pupil reference lasers mounted on the spiders of telescope secondary mirror; b) field tracker: images science object; c) pupil imager: reimages telescope pupil; d) aberration tracker: images a Shack-Hartmann. The estimation of beam stabilization parameters from the acquisition camera detector image is carried out, for every 0.7 s, with a dedicated data reduction software. The measured parameters are used in: a) alignment of GRAVITY with the VLTI; b) active pupil and field stabilization; c) defocus correction and engineering purposes. The instrument is now successfully operational on-sky in closed loop. The relevant data reduction and on-sky characterization results are reported.

astro-ph.IM

Theia: Faint objects in motion or the new astrometry frontier

In the context of the ESA M5 (medium mission) call we proposed a new satellite mission, Theia, based on relative astrometry and extreme precision to study the motion of very faint objects in the Universe. Theia is primarily designed to study the local dark matter properties, the existence of Earth-like exoplanets in our nearest star systems and the physics of compact objects. Furthermore, about 15 $\%$ of the mission time was dedicated to an open observatory for the wider community to propose complementary science cases. With its unique metrology system and "point and stare" strategy, Theia's precision would have reached the sub micro-arcsecond level. This is about 1000 times better than ESA/Gaia's accuracy for the brightest objects and represents a factor 10-30 improvement for the faintest stars (depending on the exact observational program). In the version submitted to ESA, we proposed an optical (350-1000nm) on-axis TMA telescope. Due to ESA Technology readiness level, the camera's focal plane would have been made of CCD detectors but we anticipated an upgrade with CMOS detectors. Photometric measurements would have been performed during slew time and stabilisation phases needed for reaching the required astrometric precision.

astro-ph.IM

The metrology system of the VLTI instrument GRAVITY

The VLTI instrument GRAVITY combines the beams from four telescopes and provides phase-referenced imaging as well as precision-astrometry of order 10 microarcseconds by observing two celestial objects in dual-field mode. Their angular separation can be determined from their differential OPD (dOPD) when the internal dOPDs in the interferometer are known. Here, we present the general overview of the novel metrology system which performs these measurements. The metrology consists of a three-beam laser system and a homodyne detection scheme for three-beam interference using phase-shifting interferometry in combination with lock-in amplifiers. Via this approach the metrology system measures dOPDs on a nanometer-level.

astro-ph.IM

Neutral molecular cluster formation of sulfuric acid dimethylamine observed in real time under atmospheric conditions

For atmospheric sulfuric acid (SA) concentrations the presence of dimethylamine (DMA) at mixing ratios of several parts per trillion by volume can explain observed boundary layer new particle formation rates. However, the concentration and molecular composition of the neutral (uncharged) clusters have not been reported so far due to the lack of suitable instrumentation. Here we report on experiments from the Cosmics Leaving Outdoor Droplets chamber at the European Organization for Nuclear Research revealing the formation of neutral particles containing up to 14 SA and 16 DMA molecules, corresponding to a mobility diameter of about 2 nm, under atmospherically relevant conditions. These measurements bridge the gap between the molecular and particle perspectives of nucleation, revealing the fundamental processes involved in particle formation and growth. The neutral clusters are found to form at or close to the kinetic limit where particle formation is limited only by the collision rate of SA molecules. Even though the neutral particles are stable against evaporation from the SA dimer onward, the formation rates of particles at 1.7-nm size, which contain about 10 SA molecules, are up to 4 orders of magnitude smaller comparedwith those of the dimer due to coagulation and wall loss of particles before they reach 1.7 nm in diameter. This demonstrates that neither the atmospheric particle formation rate nor its dependence on SA can simply be interpreted in terms of cluster evaporation or the molecular composition of a critical nucleus.

physics.ao-ph

The GRAVITY instrument software / High-level software

GRAVITY is the four-beam, near- infrared, AO-assisted, fringe tracking, astrometric and imaging instrument for the Very Large Telescope Interferometer (VLTI). It is requiring the development of one of the most complex instrument software systems ever built for an ESO instrument. Apart from its many interfaces and interdependencies, one of the most challenging aspects is the overall performance and stability of this complex system. The three infrared detectors and the fast reflective memory network (RMN) recorder contribute a total data rate of up to 20 MiB/s accumulating to a maximum of 250 GiB of data per night. The detectors, the two instrument Local Control Units (LCUs) as well as the five LCUs running applications under TAC (Tools for Advanced Control) architecture, are interconnected with fast Ethernet, RMN fibers and dedicated fiber connections as well as signals for the time synchronization. Here we give a simplified overview of all subsystems of GRAVITY and their interfaces and discuss two examples of high-level applications during observations: the acquisition procedure and the gathering and merging of data to the final FITS file.

astro-ph.IM

The GRAVITY Coudé Infrared Adaptive Optics (CIAO) system for the VLT Interferometer

GRAVITY is a second generation instrument for the VLT Interferometer, designed to enhance the near-infrared astrometric and spectro-imaging capabilities of VLTI. Combining beams from four telescopes, GRAVITY will provide an astrometric precision of order 10 micro-arcseconds, imaging resolution of 4 milli-arcseconds, and low and medium resolution spectro-interferometry, pushing its performance far beyond current infrared interfero- metric capabilities. To maximise the performance of GRAVITY, adaptive optics correction will be implemented at each of the VLT Unit Telescopes to correct for the effects of atmospheric turbulence. To achieve this, the GRAVITY project includes a development programme for four new wavefront sensors (WFS) and NIR-optimized real time control system. These devices will enable closed-loop adaptive correction at the four Unit Telescopes in the range 1.4-2.4 μm. This is crucially important for an efficient adaptive optics implementation in regions where optically bright references sources are scarce, such as the Galactic Centre. We present here the design of the GRAVITY wavefront sensors and give an overview of the expected adaptive optics performance under typical observing conditions. Benefiting from newly developed SELEX/ESO SAPHIRA electron avalanche photodiode (eAPD) detectors providing fast readout with low noise in the near-infrared, the AO systems are expected to achieve residual wavefront errors of \leq400 nm at an operating frequency of 500 Hz.

astro-ph.IM

HEP@Home - A distributed computing system based on BOINC

Project SETI@HOME has proven to be one of the biggest successes of distributed computing during the last years. With a quite simple approach SETI manages to process large volumes of data using a vast amount of distributed computer power. To extend the generic usage of this kind of distributed computing tools, BOINC is being developed. In this paper we propose HEP@HOME, a BOINC version tailored to the specific requirements of the High Energy Physics (HEP) community. The HEP@HOME will be able to process large amounts of data using virtually unlimited computing power, as BOINC does, and it should be able to work according to HEP specifications. In HEP the amounts of data to be analyzed or reconstructed are of central importance. Therefore, one of the design principles of this tool is to avoid data transfer. This will allow scientists to run their analysis applications and taking advantage of a large number of CPUs. This tool also satisfies other important requirements in HEP, namely, security, fault-tolerance and monitoring.

cs.DC

Grid-Brick Event Processing Framework in GEPS

Experiments like ATLAS at LHC involve a scale of computing and data management that greatly exceeds the capability of existing systems, making it necessary to resort to Grid-based Parallel Event Processing Systems (GEPS). Traditional Grid systems concentrate the data in central data servers which have to be accessed by many nodes each time an analysis or processing job starts. These systems require very powerful central data servers and make little use of the distributed disk space that is available in commodity computers. The Grid-Brick system, which is described in this paper, follows a different approach. The data storage is split among all grid nodes having each one a piece of the whole information. Users submit queries and the system will distribute the tasks through all the nodes and retrieve the result, merging them together in the Job Submit Server. The main advantage of using this system is the huge scalability it provides, while its biggest disadvantage appears in the case of failure of one of the nodes. A workaround for this problem involves data replication or backup.

cs.DC