Searcharxiv⌕ Search

arXiv subjects

Antonio C. Bruno

Publications and source records attributed to Antonio C. Bruno.

2 recordsLinked to original sources

New method for characterization of magnetic nanoparticles by scanning magnetic microscopy

In this paper, we present a new method for the magnetic characterization of bulk materials, microstructures, and nanostructures. We investigated the magnetic and morphological properties of two colloidal dispersions of iron oxide (Fe3O4) magnetic nanoparticles (MNPs), synthesized by chemical precipitation (co-precipitation) and pulsed laser ablation (PLA) in liquid, by scanning magnetic microscopy (SMM) applied to a small sample with mass on the order of tens of μg. We evaluated the performance of this technique by comparing magnetization curves and measurements obtained with commercial magnetometers, considered standard. The errors obtained for the saturation and remanent magnetization were approximately 0.18 Am2/kg and 0.6 Am2/kg, respectively. The average size distribution of the NPs estimated from the magnetization curve measurements is consistent with the results obtained by traditional transmission electron microscopy (TEM). The technique can be extended to measure and analyze magnetization curves (hysteresis loops), thus enabling an even more accurate estimation of overall NP sizes.

physics.app-ph↗

Versatile Hall magnetometer with variable sensitivity assembly for characterization of the magnetic properties of nanoparticles

A Hall magnetometer with variable sensitivity is constructed to measure the magnetic properties of magnetic nanoparticles manufactured by different methods. This novel magnetometer can also be used to measure bulk materials and samples in liquids. The magnetometer is constructed with two commercial Hall-effect sensors in an acrylic structure, which serves as the support for a micrometer and the circuit board with the sensors. For operation, the magnetometer it acquires a complete magnetization curve in a few minutes. If has a magnetic moment sensitivity of 1.3*10-9 Am2 to sensitivity of 493 mV/mT, the sensitivity can be adjustable in the range of 10 to 493 mV/mT. Its performance is tested with magnetic nanoparticles. As an application example, we estimate the mean diameter of the nanoparticles using the magnetic curves. The results are compared with those obtained by other techniques, such as transmission electron microscopy (TEM), X-ray diffraction (XRD) and dynamic light scattering (DLS). The magnetization results are also compared with those obtained by independent commercial magnetometers, which reveals errors of approximately 0.31 Am2/kg (i.e., 0.6%) in the saturation region.

physics.ins-det↗