SearcharxivSearch

arXiv subjects

Arathi Suraj

Publications and source records attributed to Arathi Suraj.

2 recordsLinked to original sources

Low-Noise SiPM Light Readout and ASIC-Based Charge Readout of a Liquid Argon Time Projection Chamber for MeV Gamma-Ray Measurements

We have developed a compact liquid argon time projection chamber (LArTPC), NanoGRAMS, as a technology demonstrator for the Gamma-Ray and AntiMatter Survey (GRAMS). LArTPCs have the potential to enable Compton cameras with unprecedented effective area in the MeV gamma-ray band. NanoGRAMS has an active volume of $5.12 \times 5.12 \times 10~\mathrm{cm^3}$ and is equipped with a low-noise scintillation and charge readout system. The scintillation light is detected by an array of 16 SiPMs ($6 \times 6~\mathrm{mm^2}$ each), whose signals are summed and amplified by a low-noise transimpedance amplifier operable at liquid argon temperature. Ionization electrons are read out with $3.2\,\mathrm{mm}$-pitch pixels and processed by VATA-SGD ASICs, with synchronization provided by an FPGA-based data acquisition system. We irradiated the detector with a $^{60}\mathrm{Co}$ source (1173 and $1332\,\mathrm{keV}$) and successfully detected both 1-hit and 2-hit events. The collected charge was converted to deposited energy using a phenomenological recombination model, and the detector response was evaluated with a Geant4-based Monte Carlo simulation. The reconstructed energy spectrum shows Compton edges at 963 and $1118\,keV$, consistent with the expected values. For 2-hit events, the sequence of interactions was identified, and the reconstructed back-projection image agrees with the source position. These results demonstrate the feasibility of NanoGRAMS as a Compton camera for MeV gamma-ray imaging spectroscopy.

astro-ph.IM

The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload

The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (<0.25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and then detecting the de-excitation X-rays and the nuclear annihilation products. This measurement is realized using a Tracker composed of more than 1000 custom silicon strip detectors and a plastic scintillator time-of-flight (TOF) system instrumenting more than 40m$^2$. Together, these subsystems provide the velocity and energy resolution, stopping power, particle tracking, and X-ray identification necessary to distinguish rare antinucleus signals from the abundant positive-nucleus backgrounds, all within the constraints of a high-altitude mission. A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign. We detail the design, integration, and commissioning of the payload prior to flight.

astro-ph.IM