SearcharxivSearch

arXiv subjects

Ariel Amar

Publications and source records attributed to Ariel Amar.

3 recordsLinked to original sources

Deep Task-Based Beamforming and Channel Data Augmentations for Enhanced Ultrasound Imaging

This paper introduces a deep learning (DL)-based framework for task-based ultrasound (US) beamforming, aiming to enhance clinical outcomes by integrating specific clinical tasks directly into the beamforming process. Task-based beamforming optimizes the beamformer not only for image quality but also for performance on a particular clinical task, such as lesion classification. The proposed framework explores two approaches: (1) a Joint Beamformer and Classifier (JBC) that classifies the US images generated by the beamformer to provide feedback for image quality improvement; and (2) a Channel Data Classifier Beamformer (CDCB) that incorporates classification directly at the channel data representation within the beamformer's bottleneck layer. Additionally, we introduce channel data augmentations to address challenges posed by noisy and limited in-vivo data. Numerical evaluations demonstrate that training with channel data augmentations significantly improves image quality. The proposed methods were evaluated against conventional Delay-and-Sum (DAS) and Minimum Variance (MV) beamforming techniques, demonstrating superior performance in terms of both image contrast and clinical relevance. Among all methods, the CDCB approach achieves the best results, outperforming others in terms of image quality and clinical relevance. These approaches exhibit significant potential for improving clinical relevance and image quality in ultrasound imaging.

eess.IV

Deep Task-Based Analog-to-Digital Conversion

Analog-to-digital converters (ADCs) allow physical signals to be processed using digital hardware. Their conversion consists of two stages: Sampling, which maps a continuous-time signal into discrete-time, and quantization, i.e., representing the continuous-amplitude quantities using a finite number of bits. ADCs typically implement generic uniform conversion mappings that are ignorant of the task for which the signal is acquired, and can be costly when operating in high rates and fine resolutions. In this work we design task-oriented ADCs which learn from data how to map an analog signal into a digital representation such that the system task can be efficiently carried out. We propose a model for sampling and quantization that facilitates the learning of non-uniform mappings from data. Based on this learnable ADC mapping, we present a mechanism for optimizing a hybrid acquisition system comprised of analog combining, tunable ADCs with fixed rates, and digital processing, by jointly learning its components end-to-end. Then, we show how one can exploit the representation of hybrid acquisition systems as deep network to optimize the sampling rate and quantization rate given the task by utilizing Bayesian meta-learning techniques. We evaluate the proposed deep task-based ADC in two case studies: the first considers symbol detection in multi-antenna digital receivers, where multiple analog signals are simultaneously acquired in order to recover a set of discrete information symbols. The second application is the beamforming of analog channel data acquired in ultrasound imaging. Our numerical results demonstrate that the proposed approach achieves performance which is comparable to operating with high sampling rates and fine resolution quantization, while operating with reduced overall bit rate.

eess.SP

Deep-Learning Based Adaptive Ultrasound Imaging from Sub-Nyquist Channel Data

Traditional beamforming of medical ultrasound images relies on sampling rates significantly higher than the actual Nyquist rate of the received signals. This results in large amounts of data to store and process, imposing hardware and software challenges on the development of ultrasound machinery and algorithms, and impacting the resulting performance. In light of the capabilities demonstrated by deep learning methods over the past years across a variety of fields, including medical imaging, it is natural to consider their ability to recover high-quality ultrasound images from partial data. Here, we propose an approach for deep-learning based reconstruction of B-mode images from temporally and spatially sub-sampled channel data. We begin by considering sub-Nyquist sampled data, time-aligned in the frequency domain and transformed back to the time domain. The data is further sampled spatially, so that only a subset of the received signals is acquired. The partial data is used to train an encoder-decoder convolutional neural network, using as targets minimum-variance (MV) beamformed signals that were generated from the original, fully-sampled data. Our approach yields high-quality B-mode images, with higher resolution than previously proposed reconstruction approaches (NESTA) from compressed data as well as delay-and-sum beamforming (DAS) of the fully-sampled data. In terms of contrast to noise ratio, our results are comparable to MV beamforming of the fully-sampled data, thus enabling better and more efficient imaging than is mostly used in clinical practice today.

eess.IV