SearcharxivSearch

arXiv subjects

Armin Reichold

Publications and source records attributed to Armin Reichold.

4 recordsLinked to original sources

Data-Driven Calibration of Large Liquid Detectors with Unsupervised Learning

This paper demonstrates a novel method to extract photomultiplier tube (PMT) calibration timing constants in large liquid scintillation detectors from physics data using the machinery of unsupervised deep learning. The approach uses a simplified physical model of optical photon transport in the loss function, with PMT calibration constants treated as free parameters, and the simple assumption that individual events represent point-like emission. The problem is, thus, effectively reduced to that of regression on a very large scale, made tractable by deep learning architectures and automatic differentiation frameworks. Using data from the 9,300 PMTs in the SNO+ detector, the method has been shown to reliably extract 3 calibration constants for each of the over 7,500 online PMTs using radioactive background events. We believe that this basic approach can be straightforwardly generalised for a wide range of applications.

physics.ins-det

Resolution of Longitudinal Profile Measures using Coherent Smith-Purcell Radiation with the Number of Gratings and the Number of Pulses Used

The E-203 collaboration is testing a device on FACET at SLAC to measure the longitudinal profile of electron bunches using Smith-Purcell radiation. At FACET the electron bunches have an energy of 20~GeV and a duration of a few hundred femtoseconds. Smith-Purcell radiation is emitted when a charged particle passes close to the surface of a metallic grating. We have studied the stability of the measurement from pulse to pulse and the resolution of the measure depending on the number of gratings used.

physics.acc-ph

Longitudinal bunch profile diagnostics in the 50fs range using coherent Smith-Purcell radiation

We have considered the possibility of using coherent Smith-Purcell radiation for the single-shot determination of the longitudinal profile of 50 fs (FWHM) long electron bunches. This length is typical for the bunches currently produced by Laser Wakefield Acceleration and is at the limit of what is achievable by alternative techniques, such as Electro-Optic sampling. It is concluded that there are no obstacles, either theoretical or experimental, in the implementation of this technique. A set of three gratings, with periods of 15, 85 and 500 micrometres, will produce detectable energy in the wavelength region 10-1000 micrometres, which should be adequate for the reconstruction of the bunch shape by the Kramers-Kronig technique. For bunch charges of 109 electrons, or more, the radiated energy can be detected by room temperature pyroelectric detectors. The limits of possible extension of the technique to even shorter lengths are also considered.

physics.acc-ph

ILC Main Linac Alignment Simulations using Conventional Techniques and the Rapid Tunnel Reference Survey Model (RTRSM)

Alignment of the ILC main linac will be more critical than for any currently existing accelerators due to its long length and the ultra low emittance required. There are several techniques for measuring the ILC reference network; in this report conventional methods for measuring the network and aligning the main linac are simulated. Dispersion Matched Steering (DMS) is applied to the simulated accelerators to determine their final emittance. Simulations and reconstructions of the ILC reference network usually require very resource intensive programs, the RTRSM has been developed to rapidly generate networks with the required statistical properties. The RTRSM is discussed in this report and some problems are demonstrated.

physics.ins-det