SearcharxivSearch

arXiv subjects

Arzoo Sharma

Publications and source records attributed to Arzoo Sharma.

3 recordsLinked to original sources

Performance Evaluation of a High-Granularity LYSO-SiPM-Based Position-Sensitive Detector for a One-Shot Gamma-Scanning System with Sub-Millimeter Spatial Resolution

A compact position-sensitive {\gamma}-detector based on a thin monolithic LYSO crystal and a 96-channel SiPM array is developed for the spatial characterization and calibration of segmented {\gamma}-ray detector systems used in nuclear-physics experiments. The detector is designed to provide localized irradiation and rapid two-dimensional response mapping. A 7 cm diameter and 3 mm thick LYSO crystal is optically coupled to the SiPM array, and the position of the incident {\gamma}-ray interaction is reconstructed from the relative scintillation-light signals collected by neighboring SiPM channels. An asymmetry-based charge-sharing method is employed to determine the interaction position from the spatial distribution of the detected scintillation light. Detailed GEANT4 simulations, including optical photon transport, were performed to investigate the detector response and estimate its intrinsic spatial resolution. The simulations predict a spatial resolution of approximately 0.5 mm for 60 keV and 511 keV {\gamma}-rays under idealized conditions. A prototype detector was developed and experimentally characterized using coincidence measurements with the {\gamma}-scanning facility at GSI, Germany. The experimental measurements demonstrate a spatial resolution better than 1 mm in the central detector region, while the position-dependent response and degradation near the detector boundaries are investigated. The experimental results are compared with GEANT4 predictions to identify the contributions of optical photon transport, charge sharing, and detector geometry to the measured spatial resolution. The developed detector provides a compact solution for the three-dimensional characterization of highly segmented {\gamma}-ray detector arrays in nuclear physics experiments.

physics.ins-det

Investigating radioactivity in soil samples from neutral and vegetation land of Punjab/India

In this work, radioactivity investigations of soil samples from neutral and agricultural sites in Punjab/India have been carried out to study the impact of land use patterns. The analysis of radiological, mineralogical, physicochemical, and morphological attributes of soil samples has been performed employing state-of-the-art techniques. The mean activity concentration of 238U, 232Th, 40K, 235U, and 137Cs, measured using a carbon-loaded p-type HPGe detector, in neutral land was observed as 58.03, 83.95, 445.18, 2.83, and 1.16Bq kg-1, respectively. However, in vegetation land, it was found to be 40.07, 64.68, 596.74, 2.26 and 2.11Bq kg-1, respectively. In the detailed activity analysis, radium equivalent (Raeq) radioactivity is found to be in the safe prescribed limit of 370Bq kg-1 for all investigated soil samples. However, the dosimetric investigations revealed that the outdoor absorbed gamma dose rate (96.08nGy h-1) and consequent annual effective dose rate (0.12mSv y-1) for neutral land, and the gamma dose rate (82.46nGy h-1) and subsequent annual effective dose rate (0.10mSv y-1) for vegetation land marginally exceeded the global average. The surface morphology of neutral land favored more compactness, while agricultural land favored high porosity. Various heavy metals of health concern, namely As, Cd, Co, Cr, Cu, Hg, Pb, Se, and Zn, were also evaluated in all soil samples using Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS). Pollution Load Index (PLI) and Ecological Risk Index (RI) revealed that vegetation land was more anthropogenically contaminated than neutral land, with maximum contamination from Hg and As.

physics.geo-ph

Role of Neutron Transfer in Sub-Barrier Fusion

Fusion excitation function of $^{35}$Cl + $^{130}$Te system is measured in the energy range around the Coulomb barrier and analyzed in the framework of the coupled-channels approach. The role of projectile deformation, nuclear structure, and the couplings of inelastic excitations and positive Q$-$value neutron transfer channels in sub-barrier fusion are investigated through the comparison of reduced fusion excitation functions of $^{35,37}$Cl +$^{130}$Te systems. The reduced fusion excitation function of $^{35}$Cl + $^{130}$Te system shows substantial enhancement over $^{37}$Cl + $^{130}$Te system in sub-barrier energy region which is attributed to the presence of positive Q-value neutron transfer channels in $^{35}$Cl + $^{130}$Te system. Findings of this work strongly suggest the importance of +2$n$ - transfer coupling in sub-barrier fusion apart from the simple inclusion of inelastic excitations of interacting partners, and are in stark contrast with the results presented by Kohley \textit{et al.}, [Phys. Rev. Lett. 107, 202701 (2011)].

nucl-ex