SearcharxivSearch

arXiv subjects

Ashish Singla

Publications and source records attributed to Ashish Singla.

3 recordsLinked to original sources

Deep RL- Tuned Mo del-Free Adaptive Control for Lower-Limb Exoskeletons During Sit-to-Stand Transitions

Sit-to-stand (STS) transitions impose significant joint-loading demands on elderly individuals, making them a primary target for lower-limb exoskeleton assistance. However, accurate trajectory tracking during STS is challenging due to complex, time-varying human exoskeleton interaction dynamics and inter-subject variability that render model-based control approaches difficult to apply in practice. This paper presents an intelligent model free adaptive backstepping control strategy for a bilateral lower-limb exoskeleton during STS motion. The proposed controller design uses an ultra-local second-order model to avoid explicit system identification, while a Gaussian radial basis function (RBF) neural network estimates the unknown lumped dynamics online. To further improve phase-aware tracking performance, a Twin Delayed Deep Deterministic Policy Gradient (TD3) reinforcement learning agent is integrated as a supervisory gain scheduler that adaptively adjusts controller gains across the distinct phases of STS motion. The proposed controller is evaluated through co-simulation in MATLAB/Simulink and Simscape Multibody using OpenSim-derived reference trajectories and benchmarked against state-of-the-art controllers. Results demonstrate that the proposed controller achieves the lowest average RMSE of 0.078 degree across all joints, representing improvements of 60.2%, 54.4%, 48.7%, and 42.6% over proportional integral derivative (PID), model-free adaptive control (MFAC), linear quadratic regulator (LQR), and sliding-mode control (SMC), respectively. TD3 integration further reduces tracking error by 35%, 33%, and 79% at the hip, knee, and ankle joints compared to the standalone RBF-MFAC baseline. These results demonstrate the effectiveness and robustness of the proposed controller design for assistive exoskeleton control during STS transitions.

cs.RO

A Novel Hybrid PID-LQR Controller for Sit-To-Stand Assistance Using a CAD-Integrated Simscape Multibody Lower Limb Exoskeleton

Precise control of lower limb exoskeletons during sit-to-stand (STS) transitions remains a central challenge in rehabilitation robotics owing to the highly nonlinear, time-varying dynamics of the human-exoskeleton system and the stringent trajectory tracking requirements imposed by clinical safety. This paper presents the systematic design, simulation, and comparative evaluation of three control strategies: a classical Proportional-Integral-Derivative (PID) controller, a Linear Quadratic Regulator (LQR), and a novel Hybrid PID-LQR controller applied to a bilateral lower limb exoskeleton performing the sit-to-stand transition. A high-fidelity, physics-based dynamic model of the exoskeleton is constructed by importing a SolidWorks CAD assembly directly into the MATLAB/Simulink Simscape Multibody environment, preserving accurate geometric and inertial properties of all links. Physiologically representative reference joint trajectories for the hip, knee, and ankle joints are generated using OpenSim musculoskeletal simulation and decomposed into three biomechanical phases: flexion-momentum (0-33%), momentum-transfer (34-66%), and extension (67-100%). The proposed Hybrid PID-LQR controller combines the optimal transient response of LQR with the integral disturbance rejection of PID through a tuned blending coefficient alpha = 0.65. Simulation results demonstrate that the Hybrid PID-LQR achieves RMSE reductions of 72.3% and 70.4% over PID at the hip and knee joints, respectively, reduces settling time by over 90% relative to PID across all joints, and limits overshoot to 2.39%-6.10%, confirming its superiority over both baseline strategies across all evaluated performance metrics and demonstrating strong translational potential for clinical assistive exoskeleton deployment.

cs.RO

Optimal Kinematic Synthesis and Prototype Development of Knee Exoskeleton

The range of rotation (RoR) in a knee exoskeleton is a critical factor in rehabilitation, as it directly influences joint mobility, muscle activation, and recovery outcomes. A well-designed RoR ensures that patients achieve near-natural knee kinematics, which is essential for restoring gait patterns and preventing compensatory movements. This paper presents optimal design of one degree of freedom knee exoskeleton. In kinematic analysis, the existing design being represented by nonlinear and nonconvex mathematical functions. To obtain feasible and optimum measurement of the links of knee exoskeleton, an optimization problem is formulated based on the kinematic analysis and average human's leg measurement. The optimized solution increases the range of motion of knee exoskeleton during sit to stand motion by $24 \%$ as compared with inspired design. Furthermore, misalignment study is conducted by comparing the trajectory of human's knee and exoskeleton's knee during sit to stand motion. The joint movement is calculated using marker and camera system. Finally, a prototype of the knee joint exoskeleton is being developed based on optimal dimensions which validate the maximum range of motion achieved during simulation.

cs.RO