Mapping of discrete range modulated proton radiograph to water-equivalent path length using machine learning

Objective. Proton beams enable localized dose delivery. Accurate range estimation is essential, but planning still relies on X-ray CT, which introduces uncertainty in stopping power and range. Proton CT measures water equivalent thickness directly but suffers resolution loss from multiple Coulomb scattering. We develop a data driven method that reconstructs water equivalent path length (WEPL) maps from energy resolved proton radiographs, bypassing intermediate reconstructions. Approach. We present a machine learning pipeline for WEPL from high dimensional radiographs. Data were generated with the TOPAS Monte Carlo toolkit, modeling a clinical nozzle and a patient CT. Proton energies spanned 70-230 MeV across 72 projection angles. Principal component analysis reduced input dimensionality while preserving signal. A conditional GAN with gradient penalty was trained for WEPL prediction using a composite loss (adversarial, MSE, SSIM, perceptual) to balance sharpness, accuracy, and stability. Main results. The model reached a mean relative WEPL deviation of 2.5 percent, an SSIM of 0.97, and a proton radiography gamma index passing rate of 97.1 percent (2 percent delta WEPL, 3 mm distance-to-agreement) on a simulated head phantom. Results indicate high spatial fidelity and strong structural agreement. Significance. WEPL can be mapped directly from proton radiographs with deep learning while avoiding intermediate steps. The method mitigates limits of analytic techniques and may improve treatment planning. Future work will tune the number of PCA components, include detector response, explore low dose settings, and extend multi angle data toward full proton CT reconstruction; it is compatible with clinical workflows.

physics.med-ph

New approaches to particle induced prompt gamma imaging

The distribution of the prompt gamma emissions induced by proton interactions in a target material carries information concerning the proton range and target composition. In order to image prompt gamma we present different approaches. The first approach is based on knife-edge collimator utilized in tandem with a compact PET type detector in order to verify proton range by measuring the depth distribution of prompt gamma relying on Compton scattered events. A second approach aims at unambiguously identifying the presence of protons in a region of interest by introducing a bio-compatible fiducial marker in the patient and measuring the characteristic prompt gamma of the marker against background material. A third approach illustrates a novel design for position sensitive gamma imaging with a millimeter level adjustable position resolution with a high detection efficiency which is a step towards 3D prompt gamma imaging, useful to better understand the target composition. Simulations of the designs were performed using GATE/Geant4 Monte Carlo framework. Experimental tests on fiducial marker were conducted at the proton facilities in INER and Chang Gung Memorial hospital. Using the knife-edge PET approach a range verification of 0.7 mm can be achieved for shifts within 1 cm near the tumor region and up to 4 mm for shifts within a 4 cm window. For the fiducial marker approach we identify 984 keV as the dominant prompt gamma and show that for the 50% relative PG intensity, the R80 position falls within a 3 mm thick 48Ti marker. Using the position sensitive gamma imaging approach we present a feasible design to achieve spatial resolution values of 2.6 mm with a detection efficiency of 5.4E-6 at 6.1 MeV and up to eight depth positions in a single run. The relative advantage of these methods and the challenges in the implementation are discussed.

physics.ins-det