SearcharxivSearch

arXiv subjects

Atsushi Shimono

Publications and source records attributed to Atsushi Shimono.

At least 19 recordsLinked to original sources

Multiple MgII Absorption Systems in the Lines of Sight to Quadruply Lensed Quasar H1413+1143

We find multiple Mg II absorption systems at redshift z=1.66, 2.069, and 2.097 in the spatially resolved spectra of the quadruply gravitationally lensed quasar H1413+1143 utilizing the Kyoto tridimensional spectrograph II (Kyoto 3DII) spectrograph on board the Subaru telescope. Here we present the first measurement of differences in Mg II absorption strength of the multiple intervening absorbers, which include ones identified as damped Lyman alpha (DLA) absorption systems. Our detection of the significant Mg II absorptions in the spatially resolved spectra reveals the inhomogeneous chemical enrichment on scales of about 12 kpc within the separation of the four sightlines. For the DLA system at z=1.66, the rest equivalent widths of the Mg II absorption lines between the four spatially resolved lines of sight change by factors of up to about 6, which trace the variations in the H I absorption strength. This suggests that inhomogeneous cold absorbers that give rise to the strong H I/Mg II absorptions dwell on a scale of about 6-12 kpc between the four lines of sight. We also investigate the degree of variation in the equivalent width of the absorption lines between the lines of sight. We find that the systems giving rise to strong absorptions in the spectra of the quadruply lensed quasars tend to have a high degree of variation in absorption strength between the lines of sight toward the lensed quasars.

astro-ph.GA

A 100-pc Scale, Fast and Dense Outflow in Narrow-Line Seyfert 1 Galaxy IRAS04576+0912

We report the initial result of an adaptive-optics assisted, optical integral-field-unit observation on IRAS04576+0912, the nearest (z=0.039) active galactic nucleus with a prominent blueshift/tail in [O III] emission from a sample of such objects that we have collected from the literature. We aim at addressing the putative quasar-mode feedback process with Subaru/Kyoto 3D II+AO188. The optical waveband (6400--7500 AA) enables us to measure the gas density via the [S II] doublets, in contrast to earlier Near-IR studies. Since the fast [O III] outflow happens only around rapidly growing central black holes, this object is suitable for investigating the black hole-galaxy coevolution. The obtained data cube exhibits blue tail in the [S II] emission at many lenslets. By fitting the spectrum with the high excess flux at the [S II] blue tail, we find the fast (~ 860 km/s), dense (>3000/cc), wide-angle and offset outflow in central 100-pc scales. Although the large opening angle and the high gas outflow-to-accretion ratio may favour the feedback hypothesis, the inferred kinetic power injection rate of this ionized gas outflow seems insufficient to influence the whole host galaxy. A conventional assumption of a low density must have overestimated the feedback process.

astro-ph.GA

H$α$ intensity map of the repeating fast radio burst FRB 121102 host galaxy from Subaru/Kyoto 3DII AO-assisted optical integral-field spectroscopy

We present the H$α$ intensity map of the host galaxy of the repeating fast radio burst FRB 121102 at a redshift of z=0.193 obtained with the AO-assisted Kyoto 3DII optical integral-field unit mounted on the 8.2-m Subaru Telescope. We detected a compact H$α$-emitting (i.e., star-forming) region in the galaxy, which has a much smaller angular size [$< 0".57$ (1.9 kpc) at full width at half maximum (FWHM)] than the extended stellar continuum emission region determined by the Gemini/GMOS z'-band image [$\simeq 1".4$ (4.6 kpc) at FWHM with ellipticity b/a=0.45]. The spatial offset between the centroid of the H$α$ emission region and the position of the radio bursts is $0".08 \pm 0".02$ ($0.26 \pm 0.07$ kpc), indicating that FRB 121102 is located within the star-forming region. This close spatial association of FRB 121102 with the star-forming region is consistent with expectations from young pulsar/magnetar models for FRB 121102, and it also suggests that the observed H$α$ emission region can make a major dispersion measure (DM) contribution to the host galaxy DM component of FRB 121102. Nevertheless, the largest possible value of the DM contribution from the H$α$ emission region inferred from our observations still requires a significant amount of ionized baryons in intergalactic medium (the so-called `missing' baryons) as the DM source of FRB 121102, and we obtain a 90\% confidence level lower limit on the cosmic baryon density in the intergalactic medium in the low-redshift universe as $Ω_{IGM} > 0.012$.

astro-ph.GA

Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview, recent progress, and future perspectives

PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6-2.7A. An international collaboration is developing this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.

astro-ph.IM

The survey operation software system development for Prime Focus Spectrograph (PFS) on Subaru Telescope

The Prime Focus Spectrograph (PFS) is a wide-field, multi-object spectrograph accommodating 2394 fibers to observe the sky at the prime focus of the Subaru telescope. The software system to operate a spectroscopic survey is structured by the four packages: Instrument control software, exposure targeting software, data reduction pipeline, and survey planning and tracking software. In addition, we operate a database system where various information such as properties of target objects, instrument configurations, and observation conditions is stored and is organized via a standardized data model for future references to update survey plans and to scientific researches. In this article, we present an overview of the software system and describe the workflows that need to be performed in the PFS operation, with some highlights on the database that organizes various information from sub-processes in the survey operation, and on the process of fiber configuration from the software perspectives.

astro-ph.IM

Visible camera cryostat design and performance for the SuMIRe Prime Focus Spectrograph (PFS)

We describe the design and performance of the SuMIRe Prime Focus Spectrograph (PFS) visible camera cryostats. SuMIRe PFS is a massively multi-plexed ground-based spectrograph consisting of four identical spectrograph modules, each receiving roughly 600 fibers from a 2394 fiber robotic positioner at the prime focus. Each spectrograph module has three channels covering wavelength ranges 380~nm -- 640~nm, 640~nm -- 955~nm, and 955~nm -- 1.26~um, with the dispersed light being imaged in each channel by a f/1.07 vacuum Schmidt camera. The cameras are very large, having a clear aperture of 300~mm at the entrance window, and a mass of $\sim$280~kg. In this paper we describe the design of the visible camera cryostats and discuss various aspects of cryostat performance.

astro-ph.IM

Metrology Camera System of Prime Focus Spectrograph for Subaru Telescope

The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph designed for the prime focus of the 8.2m Subaru telescope. PFS will cover a 1.3 degree diameter field with 2394 fibers to complement the imaging capabilities of Hyper SuprimeCam. To retain high throughput, the final positioning accuracy between the fibers and observing targets of PFS is required to be less than 10um. The metrology camera system (MCS) serves as the optical encoder of the fiber motors for the configuring of fibers. MCS provides the fiber positions within a 5um error over the 45 cm focal plane. The information from MCS will be fed into the fiber positioner control system for the closed loop control. MCS will be located at the Cassegrain focus of Subaru telescope in order to to cover the whole focal plane with one 50M pixel Canon CMOS camera. It is a 380mm Schmidt type telescope which generates a uniform spot size with a 10 micron FWHM across the field for reasonable sampling of PSF. Carbon fiber tubes are used to provide a stable structure over the operating conditions without focus adjustments. The CMOS sensor can be read in 0.8s to reduce the overhead for the fiber configuration. The positions of all fibers can be obtained within 0.5s after the readout of the frame. This enables the overall fiber configuration to be less than 2 minutes. MCS will be installed inside a standard Subaru Cassgrain Box. All components that generate heat are located inside a glycol cooled cabinet to reduce the possible image motion due to heat. The optics and camera for MCS have been delivered and tested. The mechanical parts and supporting structure are ready as of spring 2016. The integration of MCS will start in the summer of 2016.

astro-ph.IM

The Current Status of Prime Focus Instrument of Subaru Prime Focus Spectrograph

The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will cover 1.3 degree diameter field with 2394 fibers to complement the imaging capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime Focus Instrument (PFI) provides the interface with the top structure of Subaru telescope and also accommodates the optical bench in which Cobra fiber positioners are located. In addition, the acquisition and guiding cameras (AGCs), the optical fiber positioner system, the cable wrapper, the fiducial fibers, illuminator, and viewer, the field element, and the telemetry system are located inside the PFI. The mechanical structure of the PFI was designed with special care such that its deflections sufficiently match those of the HSC's Wide Field Corrector (WFC) so the fibers will stay on targets over the course of the observations within the required accuracy. In this report, the latest status of PFI development will be given including the performance of PFI components, the setup and performance of the integration and testing equipment.

astro-ph.IM

Prime Focus Spectrograph for the Subaru telescope: massively multiplexed optical and near-infrared fiber spectrograph

The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber spectrograph with 2394 science fibers distributed across a 1.3-deg diameter field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from 0.38 μm to 1.26 μm, with a resolving power of 3000, simultaneously strengthens its ability to target three main survey programs: cosmology, galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a resolving power of 5000 for 0.71 μm to 0.89 μm will also be available by simply exchanging dispersers. We highlight some of the technological aspects of the design. To transform the telescope focal ratio, a broad-band coated microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of the cable system, optimizing overall throughput; a fiber with low focal ratio degradation is selected for the fiber-positioner and fiber-slit components, minimizing the effects of fiber movements and fiber bending. Fiber positioning will be performed by a positioner consisting of two stages of piezo-electric rotary motors. The positions of these motors are measured by taking an image of artificially back-illuminated fibers with the metrology camera located in the Cassegrain container; the fibers are placed in the proper location by iteratively measuring and then adjusting the positions of the motors. Target light reaches one of the four identical fast-Schmidt spectrograph modules, each with three arms. The PFS project has passed several project-wide design reviews and is now in the construction phase.

astro-ph.IM

Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph

The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam works on the imaging part. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. Fiber positioning will be performed iteratively by taking an image of artificially back-illuminated fibers with the Metrology camera located in the Cassegrain container. The camera is carefully designed so that fiber position measurements are unaffected by small amounts of high special-frequency inaccuracies in WFC lens surface shapes. Target light carried through the fiber system reaches one of four identical fast-Schmidt spectrograph modules, each with three arms. Prototype VPH gratings have been optically tested. CCD production is complete, with standard fully-depleted CCDs for red arms and more-challenging thinner fully-depleted CCDs with blue-optimized coating for blue arms.

astro-ph.IM

Design and performance of a F/#-conversion microlens for Prime Focus Spectrograph at Subaru Telescope

The PFS is a multi-object spectrograph fed by 2394 fibers at the prime focus of Subaru telescope. Since the F/# at the prime focus is too fast for the spectrograph, we designed a small concave-plano negative lens to be attached to the tip of each fiber that converts the telescope beam (F/2.2) to F/2.8. We optimized the lens to maximize the number of rays that can be confined inside F/2.8 while maintaining a 1.28 magnification. The microlenses are manufactured by glass molding, and an ultra-broadband AR coating (<1.5% for lambda=0.38-1.26 um) will be applied to the front surface.

astro-ph.IM

Metrology Camera System of Prime Focus Spectrograph for Subaru Telescope

The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph designed for the prime focus of the 8.2m Subaru telescope. The metrology camera system of PFS serves as the optical encoder of the COBRA fiber motors for the configuring of fibers. The 380mm diameter aperture metrology camera will locate at the Cassegrain focus of Subaru telescope to cover the whole focal plane with one 50M pixel Canon CMOS sensor. The metrology camera is designed to provide the fiber position information within 5μm error over the 45cm focal plane. The positions of all fibers can be obtained within 1s after the exposure is finished. This enables the overall fiber configuration to be less than 2 minutes.

astro-ph.IM

Fiber Optical Cable and Connector System (FOCCoS) for PFS/Subaru

FOCCoS, Fiber Optical Cable and Connector System, has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this assembly allows each fiber to be placed anywhere within its patrol region, which is 9.5mm diameter.. Each positioner uses a fiber arm to support the ferrule, the microlens, and the optical fiber. 2400 of these assemblies are arranged on a motor bench plate in a hexagonal-closed-packed disposition.

astro-ph.IM

The near infrared camera for the Subaru Prime Focus Spectrograph

We present the detailed design of the near infrared camera for the SuMIRe (Subaru Measurement of Images and Redshifts) Prime Focus Spectrograph (PFS) being developed for the Subaru Telescope. The PFS spectrograph is designed to collect spectra from 2394 objects simultaneously, covering wavelengths that extend from 380 nm - 1.26 um. The spectrograph is comprised of four identical spectrograph modules, with each module collecting roughly 600 spectra from a robotic fiber positioner at the telescope prime focus. Each spectrograph module will have two visible channels covering wavelength ranges 380 nm - 640 nm and 640 nm - 955 nm, and one near infrared (NIR) channel with a wavelength range 955 nm - 1.26 um. Dispersed light in each channel is imaged by a 300 mm focal length, f/1.07, vacuum Schmidt camera onto a 4k x 4k, 15 um pixel, detector format. For the NIR channel a HgCdTe substrate-removed Teledyne 1.7 um cutoff device is used. In the visible channels, CCDs from Hamamatsu are used. These cameras are large, having a clear aperture of 300 mm at the entrance window, and a mass of ~ 250 kg. Like the two visible channel cameras, the NIR camera contains just four optical elements: a two-element refractive corrector, a Mangin mirror, and a field flattening lens. This simple design produces very good imaging performance considering the wide field and wavelength range, and it does so in large part due to the use of a Mangin mirror (a lens with a reflecting rear surface) for the Schmidt primary. In the case of the NIR camera, the rear reflecting surface is a dichroic, which reflects in-band wavelengths and transmits wavelengths beyond 1.26 um. This, combined with a thermal rejection filter coating on the rear surface of the second corrector element, greatly reduces the out-of-band thermal radiation that reaches the detector.

astro-ph.IM

Prime Focus Instrument of Prime Focus Spectrograph for Subaru Telescope

The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will cover 1.3 degree diameter field with 2394 fibers to complement the imaging capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime Focus Instrument (PFI) provides the interface with the top structure of Subaru telescope and also accommodates the optical bench in which Cobra fiber positioners are located. In addition, the acquisition and guiding (A&G) cameras, the optical fiber positioner system, the cable wrapper, the fiducial fibers, illuminator, and viewer, the field element, and the telemetry system are located inside the PFI. The mechanical structure of the PFI was designed with special care such that its deflections sufficiently match those of the HSC Wide Field Corrector (WFC) so the fibers will stay on targets over the course of the observations within the required accuracy.

astro-ph.IM

FOCCoS for Subaru PFS

The Fiber Optical Cable and Connector System (FOCCoS), provides optical connection between 2400 positioners and a set of spectrographs by an optical fibers cable as part of Subaru PFS instrument. Each positioner retains one fiber entrance attached at a microlens, which is responsible for the F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. The optical fibers cable will be segmented in 3 parts at long of the way, cable A, cable B and cable C, connected by a set of multi-fibers connectors. Cable B will be permanently attached at the Subaru telescope. The first set of multi-fibers connectors will connect the cable A to the cable C from the spectrograph system at the Nasmith platform. The cable A, is an extension of a pseudo-slit device obtained with the linear disposition of the extremities of the optical fibers and fixed by epoxy at a base of composite substrate. The second set of multi-fibers connectors will connect the other extremity of cable A to the cable B, which is part of the positioner's device structure. The optical fiber under study for this project is the Polymicro FBP120170190, which has shown very encouraging results. The kind of test involves FRD measurements caused by stress induced by rotation and twist of the fiber extremity, similar conditions to those produced by positioners of the PFS instrument. The multi-fibers connector under study is produced by USCONEC Company and may connect 32 optical fibers. The tests involve throughput of light and stability after many connections and disconnections. This paper will review the general design of the FOCCoS subsystem, methods used to fabricate the devices involved and the tests results necessary to evaluate the total efficiency of the set.

astro-ph.IM

The system software development for Prime Focus Spectrogrsph on Subaru Telescope

The Prime Focus Spectrograph (PFS) is a wide field multi-fiber spectrograph using the prime focus of the Subaru telescope, which is capable of observing up to 2400 astronomical objects simultaneously. The instrument control software will manage the observation procedure communicateing with subsystems such as the fiber positioner "COBRA", the metrology camera system, and the spectrograph and camera systems. Before an exposure starts, the instrument control system needs to access to a database where target lists provided by observers are stored in advance, and accurately position fibers onto astronomical targets as requested therein. This fiber positioning will be carried out interacting with the metrology system which measures the fiber positions. In parallel, the control system can issue a command to point the telescope to the target position and to rotate the instrument rotator. Finally the telescope pointing and the rotator angle will be checked by imaging bright stars and checking their positions on the auto-guide and acquisition cameras. After the exposure finishes, the data are collected from the detector systems and are finalized as FITS files to archive with necessary information. The observation preparation software is required, given target lists and a sequence of observation, to find optimal fiber allocations with maximizing the number of guide stars. To carry out these operations efficiently, the control system will be integrated seamlessly with a database system which will store information necessary for observation execution such as fiber configurations. In this article, the conceptual system design of the observation preparation software and the instrument control software will be presented.

astro-ph.IM

Prime Focus Spectrograph - Subaru's future -

The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advantage of Subaru's wide field of view, which is further extended with the recently completed Wide Field Corrector, PFS will enable us to carry out multi-fiber spectroscopy of 2400 targets within 1.3 degree diameter. A microlens is attached at each fiber entrance for F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. Fibers are accurately placed onto target positions by positioners, each of which consists of two stages of piezo-electric rotary motors, through iterations by using back-illuminated fiber position measurements with a wide-field metrology camera. Fibers then carry light to a set of four identical fast-Schmidt spectrographs with three color arms each: the wavelength ranges from 0.38 μm to 1.3 μm will be simultaneously observed with an average resolving power of 3000. Before and during the era of extremely large telescopes, PFS will provide the unique capability of obtaining spectra of 2400 cosmological/astrophysical targets simultaneously with an 8-10 meter class telescope. The PFS collaboration, led by IPMU, consists of USP/LNA in Brazil, Caltech/JPL, Princeton, & JHU in USA, LAM in France, ASIAA in Taiwan, and NAOJ/Subaru.

astro-ph.IM