SearcharxivSearch

arXiv subjects

Atsushi Takada

Publications and source records attributed to Atsushi Takada.

At least 19 recordsLinked to original sources

Observation of Galactic center in the sub-MeV gamma-ray band with electron-tracking Compton camera

We report the direct detection of gamma-ray emission from the Galactic center in the 150-600 keV band using the electron-tracking Compton camera (ETCC), which has a wide field of view of 3.1 sr. This represents the first application of this linear, imaging-spectroscopy method to observations of the Galactic center. Measurements in a one-day flight over Australia yielded significant gamma-ray detection in the light curve and revealed a $7.9σ$ excess over the background in the image map from the Galactic center region. These results, obtained through a simple and unambiguous analysis, demonstrate the high reliability and sensitivity of the ETCC and establish its potential for future high-precision MeV gamma-ray observations. The measured intensity and spatial distribution were tested against three emission models: a single point-like source, a multi-component structure, and a symmetric two-dimensional Gaussian. All three were found to be statistically consistent with the data. The positronium-related flux provided by the multi-component model is $(3.2~\pm~1.4) \times 10^{-2}$ photons cm$^{-2}$s$^{-1}$, consistent with the value reported by INTEGRAL within $1σ$. These results establish the potential of the ETCC for future high-precision MeV gamma-ray surveys.

astro-ph.HE

Quantitative imaging of 478-keV prompt gamma rays from boron neutron capture reactions

The accurate imaging and quantitative measurement of 478-keV prompt gamma rays are critical for advancing boron neutron capture therapy (BNCT), a promising cancer treatment. Although numerical simulations have indicated that such measurements are feasible, their practical application has proven challenging. This study introduces a gamma-ray imaging detector designed specifically for precise BNCT measurements. Using boron-rich phantom samples, we successfully imaged 478-keV gamma rays and established a linear correlation between gamma-ray production and boron concentration. Furthermore, applying this technique in a recognized BNCT treatment facility demonstrated the detector's effectiveness in monitoring boron dose distribution during neutron irradiation, both in pretreatment diagnostics and throughout the treatment process.

physics.ins-det

Development of a low-background micro pixel chamber for directional dark matter searches

Direct detection of weakly interacting massive particles (WIMPs) can provide strong evidence of their existence and the directional method would have an advantage over other methods to detect the clear signal of WIMPs. Time projection chambers with micro-patterned gaseous detectors (MPGDs) are one of the common devices used in directional WIMP searches. A micro pixel chamber ($μ$-PIC), one of the various types of MPGDs, with specially selected low background materials (LBG$μ$-PIC) was developed and its performance was studied. The radon emission of the LBG$μ$-PIC was less than 1/60 of that of the $μ$-PIC currently in use. Although a non-negligible gain non-homogeneity was seen for the LBG$μ$-PIC, it can be used for the directional WIMP search with the correction of the non-homogeneity.

physics.ins-det

High-energy extension of the gamma-ray band observable with an electron-tracking Compton camera

Although the MeV gamma-ray band is a promising energy-band window in astrophysics, the current situation of MeV gamma-ray astronomy significantly lags behind those of the other energy bands in angular resolution and sensitivity. An electron-tracking Compton camera (ETCC), a next-generation MeV detector, is expected to revolutionize the situation. An ETCC tracks each Compton-recoil electron with a gaseous electron tracker and determines the incoming direction of each gamma-ray photon; thus, it has a strong background rejection power and yields a better angular resolution than classical Compton cameras. Here, we study ETCC events in which the Compton-recoil electrons do not deposit all energies to the electron tracker but escape and hit the surrounding pixel scintillator array (PSA). We developed an analysis method for this untapped class of events and applied it to laboratory and simulation data. We found that the energy spectrum obtained from the simulation agreed with that of the actual data within a factor of 1.2. We then evaluated the detector performance using the simulation data. The angular resolution for the new-class events was found to be twice as good as in the previous study at the energy range 1.0--2.0~MeV, where both analyses overlap. We also found that the total effective area is dominated by the contribution of the double-hit events above an energy of 1.5~MeV. Notably, applying this new method extends the sensitive energy range with the ETCC from 0.2--2.1 MeV in the previous studies to up to 3.5~MeV. Adjusting the PSA dynamic range should improve the sensitivity in even higher energy gamma-rays. The development of this new analysis method would pave the way for future observations by ETCC to fill the MeV-band sensitivity gap in astronomy.

astro-ph.HE

Background contributions in the electron-tracking Compton camera onboard SMILE-2+

The Mega electron volt (MeV) gamma-ray observation is a promising diagnostic tool for observing the universe. However, the sensitivity of MeV gamma-ray telescopes is limited due to peculiar backgrounds, restricting the application of MeV gamma rays for observation. Identification of backgrounds is crucial for designing next-generation telescopes. Therefore, herein, we assessed the background contribution in the electron-tracking Compton camera (ETCC) on board the SMILE- 2+ balloon experiment. This assessment was performed using the Monte Carlo simulation. The results revealed that the background below 400 keV existed due to the atmospheric gamma-ray background, the cosmic-ray/secondary-particle background, and the accidental background. On the other hand, the unresolved background component, which was not likely to be relevant to direct Compton-scattering events in the ETCC, was confirmed above 400 keV. Overall, this study demonstrated that the Compton-kinematics test provides a powerful tool to remove the background and principally improves the signal-to-noise ratio at 400 keV by an order of magnitude.

astro-ph.IM

Direction-sensitive dark matter search with three-dimensional vector-type tracking in NEWAGE

NEWAGE is a direction-sensitive dark matter search experiment with a three-dimensional tracking detector based on a gaseous micro time projection chamber. A direction-sensitive dark matter search was carried out at Kamioka Observatory with a total live time of 318.0 days resulting in an exposure of 3.18 kg$\cdot$days. A new gamma-ray rejection and a head-tail determination analysis were implemented for this work. No significant non-isotropic signal from the directional analysis was found and a 90% confidence level upper limit on spin-dependent WIMP-proton cross section of 25.7 pb for WIMP mass of 150 GeV/c2 was derived. This upper limit is the most stringent in the direction-sensitive dark matter searches.

hep-ex

GenéLive! Generating Rhythm Actions in Love Live!

This article presents our generative model for rhythm action games together with applications in business operations. Rhythm action games are video games in which the player is challenged to issue commands at the right timings during a music session. The timings are rendered in the chart, which consists of visual symbols, called notes, flying through the screen. We introduce our deep generative model, GenéLive!, which outperforms the state-of-the-art model by taking into account musical structures through beats and temporal scales. Thanks to its favorable performance, GenéLive! was put into operation at KLab Inc., a Japan-based video game developer, and reduced the business cost of chart generation by as much as half. The application target included the phenomenal "Love Live!," which has more than 10 million users across Asia and beyond, and is one of the few rhythm action franchises that has led the online era of the genre. In this article, we evaluate the generative performance of GenéLive! using production datasets at KLab as well as open datasets for reproducibility, while the model continues to operate in their business. Our code and the model, tuned and trained using a supercomputer, are publicly available.

cs.LG

Snowmass2021 Cosmic Frontier: The landscape of cosmic-ray and high-energy photon probes of particle dark matter

This white paper discusses the current landscape and prospects for experiments sensitive to particle dark matter processes producing photons and cosmic rays. Much of the gamma-ray sky remains unexplored on a level of sensitivity that would enable the discovery of a dark matter signal. Currently operating GeV-TeV observatories, such as Fermi-LAT, atmospheric Cherenkov telescopes, and water Cherenkov detector arrays continue to target several promising dark matter-rich environments within and beyond the Galaxy. Soon, several new experiments will continue to explore, with increased sensitivity, especially extended targets in the sky. This paper reviews the several near-term and longer-term plans for gamma-ray observatories, from MeV energies up to hundreds of TeV. Similarly, the X-ray sky has been and continues to be monitored by decade-old observatories. Upcoming telescopes will further bolster searches and allow new discovery space for lines from, e.g., sterile neutrinos and axion-photon conversion. Furthermore, this overview discusses currently operating cosmic-ray probes and the landscape of future experiments that will clarify existing persistent anomalies in cosmic radiation and spearhead possible new discoveries. Finally, the article closes with a discussion of necessary cross section measurements that need to be conducted at colliders to reduce substantial uncertainties in interpreting photon and cosmic-ray measurements in space.

hep-ex

First observation of MeV gamma-ray universe with bijective imaging spectroscopy using the Electron-Tracking Compton Telescope aboard SMILE-2+

MeV gamma-rays provide a unique window for the direct measurement of line emissions from radioisotopes, but observations have made little significant progress after COMPTEL/{\it CGRO}. To observe celestial objects in this band, we are developing an electron-tracking Compton camera (ETCC), which realizes both bijective imaging spectroscopy and efficient background reduction gleaned from the recoil electron track information. The energy spectrum of the observation target can then be obtained by a simple ON-OFF method using a correctly defined point spread function on the celestial sphere. The performance of celestial object observations was validated on the second balloon SMILE-2+ installed with an ETCC having a gaseous electron tracker with a volume of 30$\times$30$\times$30 cm$^3$. Gamma-rays from the Crab nebula were detected with a significance of 4.0$σ$ in the energy range 0.15--2.1 MeV with a live time of 5.1 h, as expected before launching. Additionally, the light curve clarified an enhancement of gamma-ray events generated in the Galactic center region, indicating that a significant proportion of the final remaining events are cosmic gamma rays. Independently, the observed intensity and time variation were consistent with the pre-launch estimates except in the Galactic center region. The estimates were based on the total background of extragalactic diffuse, atmospheric, and instrumental gamma-rays after accounting for the variations in the atmospheric depth and rigidity during the level flight. The Crab results and light curve strongly support our understanding of both the detection sensitivity and the background in real observations. This work promises significant advances in MeV gamma-ray astronomy.

astro-ph.HE

Development of Convolutional Neural Networks for an Electron-Tracking Compton Camera

Electron-tracking Compton camera, which is a complete Compton camera with tracking Compton scattering electron by a gas micro time projection chamber, is expected to open up MeV gamma-ray astronomy. The technical challenge for achieving several degrees of the point spread function is the precise determination of the electron-recoil direction and the scattering position from track images. We attempted to reconstruct these parameters using convolutional neural networks. Two network models were designed to predict the recoil direction and the scattering position. These models marked 41$~$degrees of the angular resolution and 2.1$~$mm of the position resolution for 75$~$keV electron simulation data in Argon-based gas at 2$~$atm pressure. In addition, the point spread function of ETCC was improved to 15$~$degrees from 22$~$degrees for experimental data of 662$~$keV gamma-ray source. These performances greatly surpassed that using the traditional analysis.

hep-ex

Direction-sensitive dark matter search with a low-background gaseous detector NEWAGE-0.3b''

NEWAGE is a direction-sensitive dark matter search using a low-pressure gaseous time projection chamber. A low alpha-ray emission rate micro pixel chamber had been developed in order to reduce background for dark matter search. We conducted the dark matter search at the Kamioka Observatory in 2018. The total live time was 107.6 days corresponding to an exposure of 1.1 kg${\cdot}$days. Two events remained in the energy region of 50-60 keV which was consistent with 2.5 events of the expected background. A directional analysis was carried out and no significant forward-backward asymmetry derived from the WIMP-nucleus elastic scatterings was found. Thus a 90% confidence level upper limit on Spin-Dependent WIMP-proton cross section of 50 pb for a WIMP mass of 100 GeV/c2 was derived. This limit is the most stringent yet obtained from direction-sensitive dark matter search experiments.

hep-ex

First limits from a 3d-vector directional dark matter search with the NEWAGE-0.3b' detector

The first directional dark matter search with three-dimensional tracking with head-tail sensitivity (3d-vector tracking analysis) was performed with a gaseous three-dimensional tarcking detector, or the NEWAGE-0.3b' detector. The search was carried out from July 2013 to August 2017 (Run14 to Run18) at the Kamioka underground laboratory. The total livetime is 434.85 days corresponding to an exposure of 4.51 kg$\cdot$days. A 90 % confidence level upper limit on spin-dependent WIMP-proton cross section of $4.3 \times10^{2}$ pb for WIMPs with the mass of 150 GeV/$c^2$ is obtained.

hep-ex

Development of a low-$α$-emitting $μ$-PIC as a readout device for direction-sensitive dark matter detectors

Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The purpose of this study is to develop a low-background detector as a two-dimensional imaging device for a gaseous time projection chamber. In direction-sensitive dark matter experiments~(e.g. NEWAGE), $α$-rays emitted from the detector components often create substantial radioactive backgrounds. Based on the study of the background of NEWAGE, a new detector "low-$α$ $μ$-PIC" is developed. The produced $μ$-PIC performs well as a gas detector and the $α$-ray emission rate from the $μ$-PIC reduced by a factor of 100.

physics.ins-det

A Space-based All-sky MeV gamma-ray Survey with the Electron Tracking Compton Camera

A sensitive survey of the MeV gamma-ray sky is needed to understand important astrophysical problems such as gamma-ray bursts in the early universe, progenitors of Type Ia supernovae, and the nature of dark matter. However, the study has not progressed remarkably since the limited survey by COMPTEL onboard CGRO in the 1990s. Tanimori et al. have developed a Compton camera that tracks the trajectory of each recoil electron in addition to the information obtained by the conventional Compton cameras, leading to superior imaging. This Electron Tracking Compton Camera (ETCC) facilitates accurate reconstruction of the incoming direction of each MeV photon from a wide sky at ~degree angular resolution and with minimized particle background using trajectory information. The latest ETCC model, SMILE-2+, made successful astronomical observations during a day balloon flight in 2018 April and detected diffuse continuum and 511 keV annihilation line emission from the Galactic Center region at a high significance in ~2.5 hours. We believe that MeV observations from space with upgraded ETCCs will dramatically improve our knowledge of the MeV universe. We advocate for a space-based all-sky survey mission with multiple ETCCs onboard and detail its expected benefits.

astro-ph.IM

Development of a time projection chamber with a sheet-resistor field cage

A new-concept time projection chamber (TPC) using a commercial resistive sheet, sheet-resistor micro-TPC SR-microPIC, was developed and its performance was measured. SR-microTPC has the potential to create a more uniform electric field than conventional TPCs with resistor-chains owing to its continuous sheet resistivity, and its production would be easier than that of conventional TPCs. The material used in this study, Achilles-Vynilas, was found to be thin, transparent, and low-radioactive. The performance test with cosmic muons showed very promising results, including the demonstration of a good tracking-performance. This type of TPC field cage can offer an alternative for the widely used conventional field cages

physics.ins-det

Development of energy-resolved neutron imaging detectors at RADEN

Energy-resolved neutron imaging at a pulsed source utilizes the energy-dependent neutron transmission measured via time-of-flight to extract quantitative information about the internal microstructure of an object. At the RADEN instrument at J-PARC in Japan, we use cutting-edge detectors employing micro-pattern detectors or fast Li-glass scintillators and fast, all-digital data acquisition to perform such measurements, while continuing their development toward better utilization of the intense neutron source. In particular, for the Micro-Pixel Chamber based Neutron Imaging Detector (μNID), a micro-pattern detector with a 400 μm pitch and employing 3He for neutron conversion, we have successfully improved the spatial resolution from 200 to 100 μm, increased the detection efficiency from 18 to 26% for thermal neutrons, and increased the maximum count rate from 0.4 to 1 Mcps. We are also testing a new readout element with a 215 μm pitch for further improved spatial resolution, and a μNID with boron-based neutron converter for increased rate performance.

physics.ins-det

Systematic Study of Nuclear Gamma-Ray Spectra of One Hundred Super Novae Expected by Future Nuclear Gamma-Ray Imaging Spectroscopic Observations

Supernovae (SNe) are the most fascinating objects in astronomy and are intensely investigated. However, many mysteries such as nucleosynthesis and the origin of SNe Ia remain unsolved. Although the thermonuclear explosion of a single-degenerate white dwarf has been considered to be the origin of SNe Ia, a merger of two white dwarfs (double-degenerate scenario) has been frequently denoted to be more promising than a single-degenerate white dwarf. Recently the importance of observing the MeV gamma-ray band to conclusively determine the origin has been remarked. MeV gamma-rays are unique probes directly emitted from the exploding or merging region. It is evident that statistical analysis based on imaging spectroscopic observations of ~100 SNe Ia with MeV gamma-rays is necessary to obtain a definite answer. To achieve this, a telescope with a sensitivity that is 100 times that of COMPTEL is necessary. Proper imaging spectroscopy for the MeV gamma-ray band has been established by an electron-tracking Compton camera; hence, a concrete design of a MeV gamma-ray telescope has been proposed in our previous work. We have studied the details of the spectroscopic feature of SNe Ia based on the performance of a proposed telescope and found that statistical analysis can considerably suppress fluctuations of the individual properties of SNe and reveal their intrinsic differences in averaged light curves of SNe up to 60 Mpc. Our answer for the origin of SNe Ia extends to the case of single-degenerate scenario and double-degenerate coexistence scenario.

astro-ph.IM

Study of Negative-Ion TPC Using μ-PIC for Directional Dark Matter Search

Negative-ion time projection chambers(TPCs) have been studied for low-rate and high-resolution applications such as dark matter search experiments. Recently, a full volume fiducialization in a self-triggering TPC was realized. This innovative technology demonstrated a significant reduction in the background with MWPC-TPCs. We studied negative-ion TPC using the μ-PIC+GEM system and obtained sufficient gas gain with CS$_{2}$gas and SF$_{6}$ gas at low pressures. We expect an improvement in detector sensitivity and angular resolution with better electronics.

astro-ph.IM