Searcharxiv⌕ Search

arXiv subjects

Attila Répai

Publications and source records attributed to Attila Répai.

2 recordsLinked to original sources

KAYRA: A Microservice Architecture for AI-Assisted Karyotyping with Cloud and On-Premise Deployment

We present KAYRA, an end-to-end karyotyping system that operates inside the operational constraints of a clinical cytogenetic laboratory. KAYRA is architected as a containerized microservice pipeline whose ML stack combines an EfficientNet-B5 + U-Net semantic segmenter, a Mask R-CNN (ResNet-50 + FPN) instance detector, and a ResNet-18 classifier, orchestrated through a cascaded ROI-narrowing strategy that focuses each downstream model on the chromosome-bearing region. The same container images are deployed both as a cloud service and as an on-premise installation, supporting clinical environments where patient-data egress is not permitted as well as those where it is. A pilot clinical evaluation against two commercial reference karyotyping systems on 459 chromosomes from 10 metaphase spreads shows segmentation accuracy of 98.91 % (vs. 78.21 % / 40.52 %), classification accuracy of 89.1 % (vs. 86.9 % / 54.5 %), and rotation accuracy of 89.76 % (vs. 94.55 % / 78.43 %). KAYRA improves over the older density-thresholding reference on all three axes (p < 0.0001 for segmentation and classification by Fisher's exact test on chromosome-level counts), and on segmentation also against the modern AI- supported reference (p < 0.0001); on classification the difference vs. the modern AI reference is not statistically significant at the present test-set size (p = 0.34). The system reaches TRL 6 maturity and integrates the human-in-the-loop expert-review workflow that diagnostic cytogenetic practice requires. The thesis of this paper is that a multi-model cytogenetic AI service can be packaged as a microservice architecture supporting flexible deployment - cloud-hosted or on-premise - while delivering strong empirical performance on a pilot clinical evaluation.

cs.LG↗

An Open Source Validation System for Continuous Arterial Blood Pressure Measuring Sensors

Measuring the blood pressure waveform is becoming a more frequently studied area. The development of sensor technologies opens many new ways to be able to measure high-quality signals. The development of such an aim-specific sensor can be time-consuming, expensive, and difficult to test or validate with known and consistent waveforms. In this paper, we present an open source blood pressure waveform simulator with an open source Python validation package to reduce development costs for early-stage sensor development and research. The simulator mainly consists of 3D printed parts which technology has become a widely available and cheap solution. The core part of the simulator is a 3D printed cam that can be generated based on real blood pressure waveforms. The validation framework can create a detailed comparison between the signal waveform used to design the cam and the measured time series from the sensor being validated. The presented simulator proved to be robust and accurate in short- and long-term use, as it produced the signal waveform consistently and accurately. To validate this solution, a 3D force sensor was used, which was proven earlier to be able to measure high-quality blood pressure waveforms on the radial artery at the wrist. The results showed high similarity between the measured and the nominal waveforms, meaning that comparing the normalized signals, the RMSE value ranged from $0.0276 \pm 0.0047$ to $0.0212 \pm 0.0023$, and the Pearson correlation ranged from $0.9933 \pm 0.0027$ to $0.9978 \pm 0.0005$. Our validation framework is available at https://github.com/repat8/cam-bpw-sim. Our hardware framework, which allows reproduction of the presented solution, is available at https://github.com/repat8/cam-bpw-sim-hardware. The entire design is an open source project and was developed using free software.

physics.med-ph↗