A Monte Carlo positronium decay source model with multiple annihilation channels in GATE

Positronium-based imaging requires realistic modelling of positronium (Ps) decay in matter. We introduce a modular Ps decay model implemented in GATE 9.4 and GATE 10, enabling the definition of an arbitrary number of decay channels characterised by lifetime, branching fraction, annihilation multiplicity (2g/3g), and optional prompt photon emission. The model is validated through analytical and numerical benchmarks, including lifetime distributions, branching fraction consistency, photon kinematics, and prompt photon emission. Its practical applicability is demonstrated using simulations of mixed annihilation scenarios and the NEMA IEC phantom with a large field-of-view PET system. The proposed model accurately reproduces input lifetime distributions as weighted sums of exponential components and correctly samples decay channel fractions. Simulated two- and three-photon annihilation kinematics are consistent with theoretical expectations. Complex mixtures of decay channels, including varying 3g-to-2g ratios and multi-component ortho-positronium lifetimes, are correctly modelled, with observable signatures reflected in both temporal and energy distributions. Phantom simulations demonstrate the capability to generate realistic positronium-sensitive datasets. This work provides the first general-purpose, multi-channel positronium decay model integrated into GATE, enabling realistic simulations of positronium behaviour in complex media. The model supports the development and optimisation of positronium-based imaging techniques, including PLI and multi-photon PET, and applies to medical imaging, industrial tomography, and fundamental physics studies. Its public availability and compatibility with standard GATE workflows make it a valuable tool for the broader research community.

physics.med-ph↗

Development of the normalization method for the Jagiellonian PET scanner

This work aims at applying the theory of the component-based normalization for the Jagiellonian PET scanner, currently under development at the Jagiellonian University. In any Positron Emission Tomography acquisition, efficiency along a line-of-response can vary due to several physical and geometrical effects, leading to severe artifacts in the reconstructed image. To mitigate these effects, a normalization coefficient is applied to each line-of-response, defined as the product of several components. Specificity of the Jagiellonian PET scanner geometry is taken into account. Results obtained from GATE simulations are compared with preliminary results obtained from experimental data.

physics.med-ph↗

Discrete symmetries tested at 10$^{-4}$ precision using linear polarization of photons from positronium annihilations

Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of $10^{-4}$ signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.

hep-ph↗

Feasibility of the J-PET to monitor range of therapeutic proton beams

Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.

physics.med-ph↗