Searcharxiv⌕ Search

arXiv subjects

Aurélien Massire

Publications and source records attributed to Aurélien Massire.

4 recordsLinked to original sources

Combining Cartesian and non-Cartesian acceleration techniques with SPARKLING for 1mm isotropic whole-brain MPRAGE in a minute

Purpose: T1-weighted MPRAGE remains a cornerstone of clinical anatomical imaging, yet its long acquisition times constrain routine use. Established acceleration techniques, namely Parallel Imaging (PI) and Compressed Sensing (CS), tend to introduce substantial noise and blurring when pushed to high acceleration factors. Although they rely on fundamentally different redundancies, combining them synergistically remains an open challenge. Methods: The GoLF-SPARKLING framework was extended to jointly exploit two acceleration mechanisms: GRAPPA-based PI in the central k-space region and variable-density CS in the periphery, with independent acceleration factors in each zone. To preserve smooth signal evolution throughout the inversion-recovery period and avoid modulation artifacts, the acquisition trajectory was reordered accordingly. The resulting method was evaluated prospectively in vivo at 1mm isotropic resolution and benchmarked against Wave-CAIPI and Poisson-disk sampling. Results: The proposed hybrid approach produced sharper, less noisy, and more stable whole-brain images in approximately one minute than either acceleration strategy alone. Purely PI-based reconstructions were degraded by high g-factor noise, while purely CS-based reconstructions exhibited pronounced blurring. Furthermore, this method yielded lower average volumetric errors in downstream automated brain segmentation than state-of-the-art acceleration techniques, demonstrating its clinical utility. Conclusion: By jointly leveraging PI and CS, GoLF-SPARKLING achieves high acceleration factors that enable sub-minute, high-quality anatomical MRI. This translates into greater clinical throughput and more reliable imaging in patients who are challenging to scan.

eess.SP↗

Benchmarking 3D multi-coil NC-PDNet MRI reconstruction

Deep learning has shown great promise for MRI reconstruction from undersampled data, yet there is a lack of research on validating its performance in 3D parallel imaging acquisitions with non-Cartesian undersampling. In addition, the artifacts and the resulting image quality depend on the under-sampling pattern. To address this uncharted territory, we extend the Non-Cartesian Primal-Dual Network (NC-PDNet), a state-of-the-art unrolled neural network, to a 3D multi-coil setting. We evaluated the impact of channel-specific versus channel-agnostic training configurations and examined the effect of coil compression. Finally, we benchmark four distinct non-Cartesian undersampling patterns, with an acceleration factor of six, using the publicly available Calgary-Campinas dataset. Our results show that NC-PDNet trained on compressed data with varying input channel numbers achieves an average PSNR of 42.98 dB for 1 mm isotropic 32 channel whole-brain 3D reconstruction. With an inference time of 4.95sec and a GPU memory usage of 5.49 GB, our approach demonstrates significant potential for clinical research application.

eess.IV↗

Optimizing full 3D SPARKLING trajectories for high-resolution T2*-weighted Magnetic Resonance Imaging

The Spreading Projection Algorithm for Rapid K-space samplING, or SPARKLING, is an optimization-driven method that has been recently introduced for accelerated 2D T2*-w MRI using compressed sensing. It has then been extended to address 3D imaging using either stacks of 2D sampling patterns or a local 3D strategy that optimizes a single sampling trajectory at a time. 2D SPARKLING actually performs variable density sampling (VDS) along a prescribed target density while maximizing sampling efficiency and meeting the gradient-based hardware constraints. However, 3D SPARKLING has remained limited in terms of acceleration factors along the third dimension if one wants to preserve a peaky point spread function (PSF) and thus good image quality. In this paper, in order to achieve higher acceleration factors in 3D imaging while preserving image quality, we propose a new efficient algorithm that performs optimization on full 3D SPARKLING. The proposed implementation based on fast multipole methods (FMM) allows us to design sampling patterns with up to 10^7 k-space samples, thus opening the door to 3D VDS. We compare multi-CPU and GPU implementations and demonstrate that the latter is optimal for 3D imaging in the high-resolution acquisition regime (600$μ$m isotropic). Finally, we show that this novel optimization for full 3D SPARKLING outperforms stacking strategies or 3D twisted projection imaging through retrospective and prospective studies on NIST phantom and in vivo brain scans at 3 Tesla. Overall the proposed method allows for 2.5-3.75x shorter scan times compared to GRAPPA-4 parallel imaging acquisition at 3 Tesla without compromising image quality.

cs.DC↗

On Variant Strategies To Solve The Magnitude Least Squares Optimization Problem In Parallel Transmission Pulse Design And Under Strict SAR And Power Constraints

Parallel transmission has been a very promising candidate technology to mitigate the inevitable radio-frequency field inhomogeneity in magnetic resonance imaging (MRI) at ultra-high field (UHF). For the first few years, pulse design utilizing this technique was expressed as a least squares problem with crude power regularizations aimed at controlling the specific absorption rate (SAR), hence the patient safety. This approach being suboptimal for many applications sensitive mostly to the magnitude of the spin excitation, and not its phase, the magnitude least squares (MLS) problem then was first formulated in 2007. Despite its importance and the availability of other powerful numerical optimization methods, this problem yet has been faced exclusively by the pulse designer with the so-called variable exchange method. In this paper, we investigate other strategies and incorporate directly the strict SAR and hardware constraints. Different schemes such as sequential quadratic programming (SQP), interior point (I-P) methods, semi-definite programming (SDP) and magnitude squared least squares (MSLS) relaxations are studied both in the small and large tip angle regimes with real data sets obtained in-vivo on a human brain at 7 Tesla. Convergence and robustness of the different approaches are analyzed, and recommendations to tackle this specific problem are finally given. Small tip angle and inversion pulses are returned in a few seconds and in under a minute respectively while respecting the constraints, allowing the use of the proposed approach in routine.

physics.ins-det↗